Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Angew Chem Int Ed Engl ; : e202406551, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822492

RESUMO

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1-13C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22-fold (to 1,670) via parametric pumping. This active-feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T2* of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated.

2.
Anal Chem ; 96(25): 10348-10355, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38857182

RESUMO

Low-field (LF) MRI promises soft-tissue imaging without the expensive, immobile magnets of clinical scanners but generally suffers from limited detection sensitivity and contrast. The sensitivity boost provided by hyperpolarization can thus be highly synergistic with LF MRI. Initial efforts to integrate a continuous-bubbling SABRE (signal amplification by reversible exchange) hyperpolarization setup with a portable, point-of-care 64 mT clinical MRI scanner are reported. Results from 1H SABRE MRI of pyrazine and nicotinamide are compared with those of benchtop NMR spectroscopy. Comparison with MRI signals from samples with known H2O/D2O ratios allowed quantification of the SABRE enhancements of imaged samples with various substrate concentrations (down to 3 mM). Respective limits of detection and quantification of 3.3 and 10.1 mM were determined with pyrazine 1H polarization (PH) enhancements of ∼1900 (PH ∼0.04%), supporting ongoing and envisioned efforts to realize SABRE-enabled MRI-based molecular imaging.


Assuntos
Imageamento por Ressonância Magnética , Imagem Molecular , Niacinamida , Sistemas Automatizados de Assistência Junto ao Leito , Pirazinas , Niacinamida/química , Imagem Molecular/métodos , Pirazinas/química , Humanos
3.
J Law Biosci ; 11(1): lsae008, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855036

RESUMO

Researchers are rapidly developing and deploying highly portable MRI technology to conduct field-based research. The new technology will widen access to include new investigators in remote and unconventional settings and will facilitate greater inclusion of rural, economically disadvantaged, and historically underrepresented populations. To address the ethical, legal, and societal issues raised by highly accessible and portable MRI, an interdisciplinary Working Group (WG) engaged in a multi-year structured process of analysis and consensus building, informed by empirical research on the perspectives of experts and the general public. This article presents the WG's consensus recommendations. These recommendations address technology quality control, design and oversight of research, including safety of research participants and others in the scanning environment, engagement of diverse participants, therapeutic misconception, use of artificial intelligence algorithms to acquire and analyze MRI data, data privacy and security, return of results and managing incidental findings, and research participant data access and control.

4.
Ann Neurol ; 96(2): 321-331, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38738750

RESUMO

OBJECTIVE: For stroke patients with unknown time of onset, mismatch between diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) can guide thrombolytic intervention. However, access to MRI for hyperacute stroke is limited. Here, we sought to evaluate whether a portable, low-field (LF)-MRI scanner can identify DWI-FLAIR mismatch in acute ischemic stroke. METHODS: Eligible patients with a diagnosis of acute ischemic stroke underwent LF-MRI acquisition on a 0.064-T scanner within 24 h of last known well. Qualitative and quantitative metrics were evaluated. Two trained assessors determined the visibility of stroke lesions on LF-FLAIR. An image coregistration pipeline was developed, and the LF-FLAIR signal intensity ratio (SIR) was derived. RESULTS: The study included 71 patients aged 71 ± 14 years and a National Institutes of Health Stroke Scale of 6 (interquartile range 3-14). The interobserver agreement for identifying visible FLAIR hyperintensities was high (κ = 0.85, 95% CI 0.70-0.99). Visual DWI-FLAIR mismatch had a 60% sensitivity and 82% specificity for stroke patients <4.5 h, with a negative predictive value of 93%. LF-FLAIR SIR had a mean value of 1.18 ± 0.18 <4.5 h, 1.24 ± 0.39 4.5-6 h, and 1.40 ± 0.23 >6 h of stroke onset. The optimal cut-point for LF-FLAIR SIR was 1.15, with 85% sensitivity and 70% specificity. A cut-point of 6.6 h was established for a FLAIR SIR <1.15, with an 89% sensitivity and 62% specificity. INTERPRETATION: A 0.064-T portable LF-MRI can identify DWI-FLAIR mismatch among patients with acute ischemic stroke. Future research is needed to prospectively validate thresholds and evaluate a role of LF-MRI in guiding thrombolysis among stroke patients with uncertain time of onset. ANN NEUROL 2024;96:321-331.


Assuntos
Imagem de Difusão por Ressonância Magnética , AVC Isquêmico , Humanos , Idoso , Masculino , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , AVC Isquêmico/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
5.
Artigo em Inglês | MEDLINE | ID: mdl-38787662

RESUMO

Accurate image reconstruction is at the heart of diagnostics in medical imaging. Supervised deep learning-based approaches have been investigated for solving inverse problems including image reconstruction. However, these trained models encounter unseen data distributions that are widely shifted from training data during deployment. Therefore, it is essential to assess whether a given input falls within the training data distribution. Current uncertainty estimation approaches focus on providing an uncertainty map to radiologists, rather than assessing the training distribution fit. In this work, we propose a method based on the local Lipschitz metric to distinguish out-of-distribution images from in-distribution with an area under the curve of 99.94% for True Positive Rate versus False Positive Rate. We demonstrate a very strong relationship between the local Lipschitz value and mean absolute error (MAE), supported by a Spearman's rank correlation coefficient of 0.8475, to determine an uncertainty estimation threshold for optimal performance. Through the identification of false positives, we demonstrate the local Lipschitz and MAE relationship can guide data augmentation and reduce uncertainty. Our study was validated using the AUTOMAP architecture for sensor-to-image Magnetic Resonance Imaging (MRI) reconstruction. We demonstrate our approach outperforms baseline techniques of Monte-Carlo dropout and deep ensembles as well as the state-of-the-art Mean Variance Estimation (MVE) network approach. We expand our application scope to MRI denoising and Computed Tomography (CT) sparse-to-full view reconstructions using UNET architectures. We show our approach is applicable to various architectures and applications, especially in medical imaging, where preserving diagnostic accuracy of reconstructed images remains paramount.

6.
medRxiv ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38633799

RESUMO

Breast cancer screening is necessary to reduce mortality due to undetected breast cancer. Current methods have limitations, and as a result many women forego regular screening. Magnetic resonance imaging (MRI) can overcome most of these limitations, but access to conventional MRI is not widely available for routine annual screening. Here, we used an MRI scanner operating at ultra-low field (ULF) to image the left breasts of 11 women (mean age, 35 years ±13 years) in the prone position. Three breast radiologists reviewed the imaging and were able to discern the breast outline and distinguish fibroglandular tissue (FGT) from intramammary adipose tissue. Additionally, the expert readers agreed on their assessment of the breast tissue pattern including fatty, scattered FGT, heterogeneous FGT, and extreme FGT. This preliminary work demonstrates that ULF breast MRI is feasible and may be a potential option for comfortable, widely deployable, and low-cost breast cancer diagnosis and screening.

7.
Nat Commun ; 15(1): 440, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38199994

RESUMO

Magnetic resonance imaging is a widespread clinical tool for the detection of soft tissue morphology and pathology. However, the clinical deployment of magnetic resonance imaging scanners is ultimately limited by size, cost, and space constraints. Here, we discuss the design and performance of a low-field single-sided magnetic resonance sensor intended for point-of-care evaluation of skeletal muscle in vivo. The 11 kg sensor has a penetration depth of >8 mm, which allows for an accurate analysis of muscle tissue and can avoid signal from more proximal layers, including subcutaneous adipose tissue. Low operational power and shielding requirements are achieved through the design of a permanent magnet array and surface transceiver coil. The sensor can acquire high signal-to-noise measurements in minutes, making it practical as a point-of-care tool for many quantitative diagnostic measurements, including T2 relaxometry. In this work, we present the in vitro and human in vivo performance of the device for muscle tissue evaluation.


Assuntos
Imageamento por Ressonância Magnética , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Músculo Esquelético/diagnóstico por imagem , Gordura Subcutânea , Espectroscopia de Ressonância Magnética
8.
J Magn Reson Imaging ; 59(5): 1514-1522, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37767980

RESUMO

The standard of care for managing a patient with an implant is to identify the item and to assess the relative safety of scanning the patient. Because the 1.5 T MR system is the most prevalent scanner in the world and 3 T is the highest field strength in widespread use, implants typically have "MR Conditional" (i.e., an item with demonstrated safety in the MR environment within defined conditions) labeling at 1.5 and/or 3 T only. This presents challenges for a facility that has a scanner operating at a field strength below 1.5 T when encountering a patient with an implant, because scanning the patient is considered "off-label." In this case, the supervising physician is responsible for deciding whether to scan the patient based on the risks associated with the implant and the benefit of magnetic resonance imaging (MRI). For a passive implant, the MRI safety-related concerns are static magnetic field interactions (i.e., force and torque) and radiofrequency (RF) field-induced heating. The worldwide utilization of scanners operating below 1.5 T combined with the increasing incidence of patients with implants that need MRI creates circumstances that include patients potentially being subjected to unsafe imaging conditions or being denied access to MRI because physicians often lack the knowledge to perform an assessment of risk vs. benefit. Thus, physicians must have a complete understanding of the MRI-related safety issues that impact passive implants when managing patients with these products on scanners operating below 1.5 T. This monograph provides an overview of the various clinical MR systems operating below 1.5 T and discusses the MRI-related factors that influence safety for passive implants. Suggestions are provided for the management of patients with passive implants labeled MR Conditional at 1.5 and/or 3 T, referred to scanners operating below 1.5 T. The purpose of this information is to empower supervising physicians with the essential knowledge to perform MRI exams confidently and safely in patients with passive implants. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.


Assuntos
Campos Magnéticos , Próteses e Implantes , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
9.
J Magn Reson Open ; 16-172023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38090022

RESUMO

Hyperpolarization chemistry based on reversible exchange of parahydrogen, also known as Signal Amplification By Reversible Exchange (SABRE), is a particularly simple approach to attain high levels of nuclear spin hyperpolarization, which can enhance NMR and MRI signals by many orders of magnitude. SABRE has received significant attention in the scientific community since its inception because of its relative experimental simplicity and its broad applicability to a wide range of molecules, however in vivo detection of molecular probes hyperpolarized by SABRE has remained elusive. Here we describe a first demonstration of SABRE-hyperpolarized contrast detected in vivo, specifically using hyperpolarized [1-13C]pyruvate. Biocompatible formulations of hyperpolarized [1-13C]pyruvate in, both, methanol-water mixtures, and ethanol-water mixtures followed by dilution with saline and catalyst filtration were prepared and injected into healthy Sprague Dawley and Wistar rats. Effective hyperpolarization-catalyst removal was performed with silica filters without major losses in hyperpolarization. Metabolic conversion of pyruvate to lactate, alanine, and bicarbonate was detected in vivo. Pyruvate-hydrate was also observed as minor byproduct. Measurements were performed on the liver and kidney at 4.7 T via time-resolved spectroscopy and chemical-shift-resolved MRI. In addition, whole-body metabolic measurements were obtained using a cryogen-free 1.5 T MRI system, illustrating the utility of combining lower-cost MRI systems with simple, low-cost hyperpolarization chemistry to develop safe, and scalable molecular imaging.

10.
Stroke ; 54(11): 2832-2841, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37795593

RESUMO

BACKGROUND: Neuroimaging is essential for detecting spontaneous, nontraumatic intracerebral hemorrhage (ICH). Recent data suggest ICH can be characterized using low-field magnetic resonance imaging (MRI). Our primary objective was to investigate the sensitivity and specificity of ICH on a 0.064T portable MRI (pMRI) scanner using a methodology that provided clinical information to inform rater interpretations. As a secondary aim, we investigated whether the incorporation of a deep learning (DL) reconstruction algorithm affected ICH detection. METHODS: The pMRI device was deployed at Yale New Haven Hospital to examine patients presenting with stroke symptoms from October 26, 2020 to February 21, 2022. Three raters independently evaluated pMRI examinations. Raters were provided the images alongside the patient's clinical information to simulate real-world context of use. Ground truth was the closest conventional computed tomography or 1.5/3T MRI. Sensitivity and specificity results were grouped by DL and non-DL software to investigate the effects of software advances. RESULTS: A total of 189 exams (38 ICH, 89 acute ischemic stroke, 8 subarachnoid hemorrhage, 3 primary intraventricular hemorrhage, 51 no intracranial abnormality) were evaluated. Exams were correctly classified as positive or negative for ICH in 185 of 189 cases (97.9% overall accuracy). ICH was correctly detected in 35 of 38 cases (92.1% sensitivity). Ischemic stroke and no intracranial abnormality cases were correctly identified as blood-negative in 139 of 140 cases (99.3% specificity). Non-DL scans had a sensitivity and specificity for ICH of 77.8% and 97.1%, respectively. DL scans had a sensitivity and specificity for ICH of 96.6% and 99.3%, respectively. CONCLUSIONS: These results demonstrate improvements in ICH detection accuracy on pMRI that may be attributed to the integration of clinical information in rater review and the incorporation of a DL-based algorithm. The use of pMRI holds promise in providing diagnostic neuroimaging for patients with ICH.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , AVC Isquêmico/complicações , Tomografia Computadorizada por Raios X , Hemorragia Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Imageamento por Ressonância Magnética
11.
Nat Rev Bioeng ; 1(9): 617-630, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37705717

RESUMO

The advent of portable, low-field MRI (LF-MRI) heralds new opportunities in neuroimaging. Low power requirements and transportability have enabled scanning outside the controlled environment of a conventional MRI suite, enhancing access to neuroimaging for indications that are not well suited to existing technologies. Maximizing the information extracted from the reduced signal-to-noise ratio of LF-MRI is crucial to developing clinically useful diagnostic images. Progress in electromagnetic noise cancellation and machine learning reconstruction algorithms from sparse k-space data as well as new approaches to image enhancement have now enabled these advancements. Coupling technological innovation with bedside imaging creates new prospects in visualizing the healthy brain and detecting acute and chronic pathological changes. Ongoing development of hardware, improvements in pulse sequences and image reconstruction, and validation of clinical utility will continue to accelerate this field. As further innovation occurs, portable LF-MRI will facilitate the democratization of MRI and create new applications not previously feasible with conventional systems.

12.
J Magn Reson ; 354: 107521, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37487304

RESUMO

We report on hyperpolarization of quadrupolar (I=3/2) 131Xe via spin-exchange optical pumping. Observations of the 131Xe polarization dynamics via in situ low-field NMR show that the estimated alkali-metal/131Xe spin-exchange rates can be large enough to compete with 131Xe spin relaxation. 131Xe polarization up to 7.6±1.5% was achieved in ∼8.5×1020 spins-a ∼100-fold improvement in the total spin angular momentum-potentially enabling various applications, including: measurement of spin-dependent neutron-131Xe s-wave scattering; sensitive searches for time-reversal violation in neutron-131Xe interactions beyond the Standard Model; and surface-sensitive pulmonary MRI.

13.
Magn Reson Med ; 90(4): 1682-1694, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37345725

RESUMO

In March 2022, the first ISMRM Workshop on Low-Field MRI was held virtually. The goals of this workshop were to discuss recent low field MRI technology including hardware and software developments, novel methodology, new contrast mechanisms, as well as the clinical translation and dissemination of these systems. The virtual Workshop was attended by 368 registrants from 24 countries, and included 34 invited talks, 100 abstract presentations, 2 panel discussions, and 2 live scanner demonstrations. Here, we report on the scientific content of the Workshop and identify the key themes that emerged. The subject matter of the Workshop reflected the ongoing developments of low-field MRI as an accessible imaging modality that may expand the usage of MRI through cost reduction, portability, and ease of installation. Many talks in this Workshop addressed the use of computational power, efficient acquisitions, and contemporary hardware to overcome the SNR limitations associated with low field strength. Participants discussed the selection of appropriate clinical applications that leverage the unique capabilities of low-field MRI within traditional radiology practices, other point-of-care settings, and the broader community. The notion of "image quality" versus "information content" was also discussed, as images from low-field portable systems that are purpose-built for clinical decision-making may not replicate the current standard of clinical imaging. Speakers also described technical challenges and infrastructure challenges related to portability and widespread dissemination, and speculated about future directions for the field to improve the technology and establish clinical value.


Assuntos
Imageamento por Ressonância Magnética , Radiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Software
14.
J Am Heart Assoc ; 12(11): e029242, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37218590

RESUMO

Background White matter hyperintensity (WMH) on magnetic resonance imaging (MRI) of the brain is associated with vascular cognitive impairment, cardiovascular disease, and stroke. We hypothesized that portable magnetic resonance imaging (pMRI) could successfully identify WMHs and facilitate doing so in an unconventional setting. Methods and Results In a retrospective cohort of patients with both a conventional 1.5 Tesla MRI and pMRI, we report Cohen's kappa (κ) to measure agreement for detection of moderate to severe WMH (Fazekas ≥2). In a subsequent prospective observational study, we enrolled adult patients with a vascular risk factor being evaluated in the emergency department for a nonstroke complaint and measured WMH using pMRI. In the retrospective cohort, we included 33 patients, identifying 16 (49.5%) with WMH on conventional MRI. Between 2 raters evaluating pMRI, the interrater agreement on WMH was strong (κ=0.81), and between 1 rater for conventional MRI and the 2 raters for pMRI, intermodality agreement was moderate (κ=0.66, 0.60). In the prospective cohort we enrolled 91 individuals (mean age, 62.6 years; 53.9% men; 73.6% with hypertension), of which 58.2% had WMHs on pMRI. Among 37 Black and Hispanic individuals, the Area Deprivation Index was higher (versus White, 51.8±12.9 versus 37.9±11.9; P<0.001). Among 81 individuals who did not have a standard-of-care MRI in the preceding year, we identified WMHs in 43 of 81 (53.1%). Conclusions Portable, low-field imaging could be useful for identifying moderate to severe WMHs. These preliminary results introduce a novel role for pMRI outside of acute care and the potential role for pMRI to reduce disparities in neuroimaging.


Assuntos
Substância Branca , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Feminino , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Estudos Prospectivos , Estudos Retrospectivos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética
15.
J Am Chem Soc ; 145(20): 11121-11129, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37172079

RESUMO

Conventional nuclear magnetic resonance (NMR) enables detection of chemicals and their transformations by exciting nuclear spin ensembles with a radio-frequency pulse followed by detection of the precessing spins at their characteristic frequencies. The detected frequencies report on chemical reactions in real time and the signal amplitudes scale with concentrations of products and reactants. Here, we employ Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), a quantum phenomenon producing coherent emission of 13C signals, to detect chemical transformations. The 13C signals are emitted by the negatively hyperpolarized biomolecules without external radio frequency pulses and without any background signal from other, nonhyperpolarized spins in the ensemble. Here, we studied the hydrolysis of hyperpolarized ethyl-[1-13C]acetate to hyperpolarized [1-13C]acetate, which was analyzed as a model system by conventional NMR and 13C RASER. The chemical transformation of 13C RASER-active species leads to complete and abrupt disappearance of reactant signals and delayed, abrupt reappearance of a frequency-shifted RASER signal without destroying 13C polarization. The experimentally observed "quantum" RASER threshold is supported by simulations.

16.
Med Phys ; 50(4): 1962-1974, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36646444

RESUMO

BACKGROUND: MRI-guidance techniques that dynamically adapt radiation beams to follow tumor motion in real time will lead to more accurate cancer treatments and reduced collateral healthy tissue damage. The gold-standard for reconstruction of undersampled MR data is compressed sensing (CS) which is computationally slow and limits the rate that images can be available for real-time adaptation. PURPOSE: Once trained, neural networks can be used to accurately reconstruct raw MRI data with minimal latency. Here, we test the suitability of deep-learning-based image reconstruction for real-time tracking applications on MRI-Linacs. METHODS: We use automated transform by manifold approximation (AUTOMAP), a generalized framework that maps raw MR signal to the target image domain, to rapidly reconstruct images from undersampled radial k-space data. The AUTOMAP neural network was trained to reconstruct images from a golden-angle radial acquisition, a benchmark for motion-sensitive imaging, on lung cancer patient data and generic images from ImageNet. Model training was subsequently augmented with motion-encoded k-space data derived from videos in the YouTube-8M dataset to encourage motion robust reconstruction. RESULTS: AUTOMAP models fine-tuned on retrospectively acquired lung cancer patient data reconstructed radial k-space with equivalent accuracy to CS but with much shorter processing times. Validation of motion-trained models with a virtual dynamic lung tumor phantom showed that the generalized motion properties learned from YouTube lead to improved target tracking accuracy. CONCLUSION: AUTOMAP can achieve real-time, accurate reconstruction of radial data. These findings imply that neural-network-based reconstruction is potentially superior to alternative approaches for real-time image guidance applications.


Assuntos
Neoplasias Pulmonares , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Movimento (Física) , Processamento de Imagem Assistida por Computador/métodos
17.
Neurology ; 100(22): 1067-1071, 2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-36720639

RESUMO

In the 20th century, the advent of neuroimaging dramatically altered the field of neurologic care. However, despite iterative advances since the invention of CT and MRI, little progress has been made to bring MR neuroimaging to the point of care. Recently, the emergence of a low-field (<1 T) portable MRI (pMRI) is setting the stage to revolutionize the landscape of accessible neuroimaging. Users can transport the pMRI into a variety of locations, using a standard 110-220 V wall outlet. In this article, we discuss current applications for pMRI, including in the acute and critical care settings, the barriers to broad implementation, and future opportunities.


Assuntos
Imageamento por Ressonância Magnética , Neurologia , Humanos , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Neurologia/história
18.
Radiology ; 306(3): e220522, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36346311

RESUMO

Background Portable, low-field-strength (0.064-T) MRI has the potential to transform neuroimaging but is limited by low spatial resolution and low signal-to-noise ratio. Purpose To implement a machine learning super-resolution algorithm that synthesizes higher spatial resolution images (1-mm isotropic) from lower resolution T1-weighted and T2-weighted portable brain MRI scans, making them amenable to automated quantitative morphometry. Materials and Methods An external high-field-strength MRI data set (1-mm isotropic scans from the Open Access Series of Imaging Studies data set) and segmentations for 39 regions of interest (ROIs) in the brain were used to train a super-resolution convolutional neural network (CNN). Secondary analysis of an internal test set of 24 paired low- and high-field-strength clinical MRI scans in participants with neurologic symptoms was performed. These were part of a prospective observational study (August 2020 to December 2021) at Massachusetts General Hospital (exclusion criteria: inability to lay flat, body habitus preventing low-field-strength MRI, presence of MRI contraindications). Three well-established automated segmentation tools were applied to three sets of scans: high-field-strength (1.5-3 T, reference standard), low-field-strength (0.064 T), and synthetic high-field-strength images generated from the low-field-strength data with the CNN. Statistical significance of correlations was assessed with Student t tests. Correlation coefficients were compared with Steiger Z tests. Results Eleven participants (mean age, 50 years ± 14; seven men) had full cerebrum coverage in the images without motion artifacts or large stroke lesion with distortion from mass effect. Direct segmentation of low-field-strength MRI yielded nonsignificant correlations with volumetric measurements from high field strength for most ROIs (P > .05). Correlations largely improved when segmenting the synthetic images: P values were less than .05 for all ROIs (eg, for the hippocampus [r = 0.85; P < .001], thalamus [r = 0.84; P = .001], and whole cerebrum [r = 0.92; P < .001]). Deviations from the model (z score maps) visually correlated with pathologic abnormalities. Conclusion This work demonstrated proof-of-principle augmentation of portable MRI with a machine learning super-resolution algorithm, which yielded highly correlated brain morphometric measurements to real higher resolution images. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Ertl-Wagner amd Wagner in this issue. An earlier incorrect version appeared online. This article was corrected on February 1, 2023.


Assuntos
Imageamento por Ressonância Magnética , Acidente Vascular Cerebral , Masculino , Humanos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Aprendizado de Máquina , Neuroimagem
19.
Sci Adv ; 8(28): eabp8483, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35857519

RESUMO

The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/T2*. Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. Small local differences in initial population inversion density can create stronger image contrast than conventional MRI. This different contrast mechanism is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Contrast mechanism and artifacts are explored experimentally and predicted by simulations on the basis of a proposed RASER MRI theory.

20.
Ann Neurol ; 92(4): 574-587, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35689531

RESUMO

Brain imaging is essential to the clinical care of patients with stroke, a leading cause of disability and death worldwide. Whereas advanced neuroimaging techniques offer opportunities for aiding acute stroke management, several factors, including time delays, inter-clinician variability, and lack of systemic conglomeration of clinical information, hinder their maximal utility. Recent advances in deep machine learning (DL) offer new strategies for harnessing computational medical image analysis to inform decision making in acute stroke. We examine the current state of the field for DL models in stroke triage. First, we provide a brief, clinical practice-focused primer on DL. Next, we examine real-world examples of DL applications in pixel-wise labeling, volumetric lesion segmentation, stroke detection, and prediction of tissue fate postintervention. We evaluate recent deployments of deep neural networks and their ability to automatically select relevant clinical features for acute decision making, reduce inter-rater variability, and boost reliability in rapid neuroimaging assessments, and integrate neuroimaging with electronic medical record (EMR) data in order to support clinicians in routine and triage stroke management. Ultimately, we aim to provide a framework for critically evaluating existing automated approaches, thus equipping clinicians with the ability to understand and potentially apply DL approaches in order to address challenges in clinical practice. ANN NEUROL 2022;92:574-587.


Assuntos
Aprendizado Profundo , Acidente Vascular Cerebral , Humanos , Redes Neurais de Computação , Neuroimagem/métodos , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...