Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37992562

RESUMO

We describe the simultaneous quantification of six antiviral drugs in serum based on high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The target drugs-hydroxychloroquine, chloroquine, favipiravir, umifenovir, ritonavir, and lopinavir-were extracted and purified from serum with 75 % v/v methanol as the precipitant reagent. The six analytes were clearly separated within 15 min using gradient elution and mixed-mode stationary phase. The measurement accuracy and precision were assured by adopting isotopes as internal standards. The optimized measurement procedure was strictly validated in linearity, sensitivity, accuracy, and precision. To confirm the robustness of the method in matrix, the method was additionally applied to various types of serum, namely hyperlipidemic and hyperglycemic serum. The method was then applied to assess the stability of the drugs in serum in order to set sample handling and storage guides for laboratory testing. Lastly, the method was implemented in different LC-MS systems to confirm its applicability across similar equipment commonly used in clinical testing laboratories. The overall results show that the optimized protocol is suitable for the accurate, simultaneous quantification of the six antiviral drugs in serum, and it is anticipated to satisfactorily serve as a reference protocol for the analysis of a wide range of other antiviral drugs for drug monitoring with various purposes.


Assuntos
Antivirais , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Isótopos , Reprodutibilidade dos Testes
2.
Anal Chem ; 94(28): 10127-10134, 2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35802862

RESUMO

To achieve the measurement reliability of amino acids used as diagnostic markers in clinical fields, establishing a reference measurement system is required, in which certified reference materials (CRMs) are an essential step in the hierarchy of measurement traceability. This study describes the development of dried blood spot (DBS) CRMs for amino acid analysis with complete measurement traceability to the International System of Units (SI). Six essential amino acids─proline, valine, isoleucine, leucine, phenylalanine, and tyrosine─were analyzed using isotope-dilution liquid chromatography-mass spectrometry (ID-MS). For minimizing measurement bias and uncertainty overestimation, whole spots with 50 µL of whole blood were adopted in the certification. The between-spot homogeneities by whole spot sampling were lower than 2.1%. The relative expanded uncertainties of the six amino acids in the developed DBS CRMs were lower than 5.7% at 95% confidence. The certified values are traceable to SI through both gravimetric preparation and the primary method in certification, ID-MS. Comparison among DBS testing laboratories revealed discrepancies between the whole spot and disc sampling methods. The actual sampling volume was accurately estimated by weighing, which revealed the possibility of underestimation in routine DBS testing. The candidate CRMs can support the standardization of DBS testing for amino acids through the qualification and validation of many kinds of measurement procedures to compensate the measurement bias caused by matrix-specific sampling error.


Assuntos
Aminoácidos , Teste em Amostras de Sangue Seco , Aminoácidos/análise , Certificação , Cromatografia Líquida/métodos , Padrões de Referência , Reprodutibilidade dos Testes
3.
J Clin Lab Anal ; 36(7): e24521, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35622611

RESUMO

BACKGROUND: The standardization of measurement aims to achieve comparability of results regardless of the analytical methods and the laboratory where analyses are carried out. In this paper, a comparison of results from several immunoassay-based insulin analysis kits is described, and the steps necessary to improve comparability are discussed. METHODS: Four manual enzyme-linked immunosorbent assay (ELISA) kits produced by Mercodia, Alpco, Epitope Diagnostics, and Abcam, and three automated chemiluminescent (CLIA) insulin assay kits (Siemens Centaur XP, Unicel Dxl800, Cobas e801) were compared by analyzing human serum samples and certified reference materials for human insulin. RESULTS: The seven evaluated assay kits showed substantial discrepancies in the results, with relative standard deviation ranges between 1.7% and 23.2%. We find that the traceability chains and the unit conversion factors are not yet harmonized, and current reference materials for insulin are not applicable for immunoassay-based method validation due to the use of different matrices. CONCLUSIONS: The findings suggest the need to fine tune insulin analysis methods, measurement traceability, and any conversion factor used in post-analysis steps in accordance with the necessity for standardization.


Assuntos
Testes Imunológicos , Insulina , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoensaio/métodos , Padrões de Referência
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1126-1127: 121732, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31376580

RESUMO

A certified reference material (CRM) for the quantification of protein, essential to manage quality control and quality assurance in protein-related works, has been developed. Amino acid analysis with conventional acid hydrolysis and isotope dilution HPLC-MS was used to establish an SI-traceable absolute protein quantification method using recombinant human growth hormone (hGH) as a model protein. The certification method was verified by comparative studies between 1) different methods of protein quantification based on microwave-assisted hydrolysis, and 2) different labs as part of the Asian Collaboration on Reference Material project with Japan, China, and Korea. Certification, evaluation of measurement uncertainty, homogeneity testing, and stability testing were carried out, after which the candidate CRM for hGH quantification was successfully certified with excellent agreement within the certified value in the two comparative studies. Although the quantification value of hGH by amino acid analysis showed good robustness in various conditions, results of intact protein analysis showed degradation profiles in temperatures higher than 4 °C. Consequently, storage and dissemination conditions should be set in accordance with stability tests. Based on the results, this method is believed to be suitable for accurate quantification of hGH. Additionally, it can also be used as a guide to preparation of CRM, and instructions for quality management of protein work for other similar proteins.


Assuntos
Hormônio do Crescimento Humano , Proteínas Recombinantes , Cromatografia Líquida de Alta Pressão/normas , Hormônio do Crescimento Humano/análise , Hormônio do Crescimento Humano/química , Humanos , Espectrometria de Massas/normas , Estabilidade Proteica , Proteínas Recombinantes/análise , Proteínas Recombinantes/química , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...