1.
Strahlenther Onkol ; 182(11): 647-52, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17072522

RESUMO

BACKGROUND AND PURPOSE: There is concern about the increase of radiation-induced malignancies with the application of modern radiation treatment techniques such as intensity-modulated radiotherapy (IMRT) and proton radiotherapy. Therefore, X-ray scatter and neutron radiation as well as the impact of the primary dose distribution on secondary cancer incidence are analyzed. MATERIAL AND METHODS: The organ equivalent dose (OED) concept with a linear-exponential and a plateau dose-response curve was applied to dose distributions of 30 patients who received radiation therapy of prostate cancer. Three-dimensional conformal radiotherapy was used in eleven patients, another eleven patients received IMRT with 6-MV photons, and eight patients were treated with spot-scanned protons. The treatment plans were recalculated with 15-MV and 18-MV photons. Secondary cancer risk was estimated based on the OED for the different treatment techniques. RESULTS: A modest increase of 15% radiation-induced cancer results from IMRT using low energies (6 MV), compared to conventional four-field planning with 15-MV photons (plateau dose-response: 1%). The probability to develop a secondary cancer increases with IMRT of higher energies by 20% and 60% for 15 MV and 18 MV, respectively (plateau dose-response: 2% and 30%). The use of spot-scanned protons can reduce secondary cancer incidence as much as 50% (independent of dose-response). CONCLUSION: By including the primary dose distribution into the analysis of radiation-induced cancer incidence, the resulting increase in risk for secondary cancer using modern treatment techniques such as IMRT is not as dramatic as expected from earlier studies. By using 6-MV photons, only a moderate risk increase is expected. Spot-scanned protons are the treatment of choice in regard to secondary cancer incidence.


Assuntos
Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias da Próstata/radioterapia , Terapia com Prótons , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Relação Dose-Resposta à Radiação , Humanos , Incidência , Masculino , Modelos Teóricos , Imagens de Fantasmas , Probabilidade , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Eficiência Biológica Relativa , Fatores de Risco , Espalhamento de Radiação , Tomografia Computadorizada por Raios X
2.
Int J Radiat Oncol Biol Phys ; 61(5): 1510-5, 2005 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15817357

RESUMO

PURPOSE: Estimates of secondary cancer risk after radiotherapy are becoming more important for comparative treatment planning. Modern treatment planning systems provide accurate three-dimensional dose distributions for each individual patient. These data open up new possibilities for more precise estimates of secondary cancer incidence rates in the irradiated organs. We report a new method to estimate organ-specific radiation-induced cancer incidence rates. The concept of an organ equivalent dose (OED) for radiation-induced cancer assumes that any two dose distributions in an organ are equivalent if they cause the same radiation-induced cancer incidence. METHODS AND MATERIALS: The two operational parameters of the OED concept are the organ-specific cancer incidence rate at low doses, which is taken from the data of the atomic bomb survivors, and cell sterilization at higher doses. The effect of cell sterilization in various organs was estimated by analyzing the secondary cancer incidence data of patients with Hodgkin's disease who were treated with radiotherapy in between 1962 and 1993. The radiotherapy plans used at the time the patients had been treated were reconstructed on a fully segmented whole body CT scan. The dose distributions were calculated in individual organs for which cancer incidence data were available. The model parameter that described cell sterilization was obtained by analyzing the dose and cancer incidence rates for the individual organs. RESULTS: We found organ-specific cell radiosensitivities that varied from 0.017 for the mouth and pharynx up to 1.592 for the bladder. Using the two model parameters (organ-specific cancer incidence rate and the parameter characterizing cell sterilization), the OED concept can be applied to any three-dimensional dose distribution to analyze cancer incidence. CONCLUSION: We believe that the concept of OED presented in this investigation represents a first step in assessing the potential risk of secondary cancer induction after the clinical application of radiotherapy.


Assuntos
Neoplasias Induzidas por Radiação/epidemiologia , Segunda Neoplasia Primária/epidemiologia , Tolerância a Radiação , Relação Dose-Resposta à Radiação , Humanos , Incidência , Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Especificidade de Órgãos/efeitos da radiação