Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
BMC Pediatr ; 22(1): 464, 2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35918685

RESUMO

BACKGROUND: Post-mortem imaging has been suggested as an alternative to conventional autopsy in the prenatal and postnatal periods. Noninvasive autopsies do not provide tissue for histological examination, which may limit their clinical value, especially when infection-related morbidity and mortality are suspected. METHODS: We performed a prospective, multicentre, cross-sectional study to compare the diagnostic performance of post-mortem magnetic resonance imaging with computed tomography-guided biopsy (Virtopsy®) with that of conventional autopsy in foetuses and infants. Cases referred for conventional autopsy were eligible for enrolment. After post-mortem imaging using a computed tomography scanner and a magnetic resonance imaging unit, computed tomography-guided tissue sampling was performed. Virtopsy results were compared with conventional autopsy in determining the likely final cause of death and major pathologies. The primary outcome was the proportion of cases for which the same cause of death was determined by both methods. Secondary outcomes included the proportion of false positive and false negative major pathological lesions detected by virtopsy and the proportion of computed tomography-guided biopsies that were adequate for histological examination. RESULTS: Overall, 101 cases (84 fetuses, 17 infants) were included. Virtopsy and autopsy identified the same cause of death in 91 cases (90.1%, 95% CI 82.7 to 94.5). The sensitivity and specificity of virtopsy for determining the cause of death were 96.6% (95% CI 90.6 to 98.8) and 41.7% (95% CI 19.3 to 68.0), respectively. In 32 cases (31.7%, 95% CI 23.4 to 41.3), major pathological findings remained undetected by virtopsy, and in 45 cases (44.6%, 95% CI 35.2 to 54.3), abnormalities were diagnosed by virtopsy but not confirmed by autopsy. Computed tomography-guided tissue sampling was adequate for pathological comments in 506 of 956 biopsies (52.7%) and added important diagnostic value in five of 30 cases (16.1%) with an unclear cause of death before autopsy compared with postmortem imaging alone. In 19 of 20 infective deaths (95%), biopsies revealed infection-related tissue changes. Infection was confirmed by placental examination in all fetal cases. CONCLUSIONS: Virtopsy demonstrated a high concordance with conventional autopsy for the detection of cause of death but was less accurate for the evaluation of major pathologies. Computed tomography-guided biopsy had limited additional diagnostic value. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01888380).


Assuntos
Placenta , Tomografia Computadorizada por Raios X , Biópsia , Estudos Transversais , Feminino , Feto/diagnóstico por imagem , Humanos , Lactente , Imageamento por Ressonância Magnética/métodos , Gravidez , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Meat Sci ; 135: 74-78, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28938106

RESUMO

Water buffaloes and cattle differ considerably with respect to the anatomy of the head. As a result, captive bolt stunners often fail to reliably produce adequate loss of consciousness in water buffaloes and, thus, do not fulfill animal welfare requirements. The goal of the present study was to assess and validate a new stunning device for water buffaloes meeting animal welfare and occupational safety requirements. The newly designed bullet casing gun uses .357Mag/10.2g hollow point bullets and has additional safety features. Its effectiveness and usability were assessed under practical conditions in an abattoir as based on widely accepted criteria. Stunning resulted in deep unconsciousness in 19 out of 20 water buffaloes. One 9-year old male did not immediately collapse. Except for very old bulls, the device presented herewith provides a means to stun water buffaloes of both sexes effectively and reliably while keeping occupational hazards to a minimum.


Assuntos
Búfalos , Estado de Consciência/fisiologia , Desenho de Equipamento , Matadouros , Bem-Estar do Animal , Animais , Feminino , Armas de Fogo , Masculino , Suíça
4.
Meat Sci ; 135: 159-165, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29035813

RESUMO

Stock management of the Swiss water buffalo livestock results in the slaughtering of about 350 animals per year. As the stunning of water buffaloes still is an unresolved issue, we investigated the terminal ballistics of currently used perforating stunning devices. Cartridge fired captive bolt devices, handguns and a bullet casing gun were tested in a shooting steep by firing on bisected heads, forehead plates and soap blocks. Energy loss of captive bolts confirmed their inadequacy when used for heavy water buffaloes, notably adult males. As for the free projectiles, ballistics revealed that beyond the impact energy, bullet deformation has a strong impact on the outcome. Light 9mm Luger or .38 Spl bullets as well as large deformable .44 Rem. Magnum bullets should be avoided in favor of heavier .357 Magnum deformation ammunition. These data have been translated into the development of a new stunning device for water buffaloes meeting both animal welfare and occupational safety requirements.


Assuntos
Matadouros , Búfalos , Armas de Fogo/normas , Fatores Etários , Bem-Estar do Animal , Animais , Fenômenos Biomecânicos , Feminino , Cabeça , Masculino , Suíça
5.
Surg Neurol Int ; 8: 290, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29285406

RESUMO

BACKGROUND: Despite multiple advantages of minimally invasive techniques in spinal surgery, the currently used approaches may lead to postoperative pain and spinal instability. As a natural orifice, the hiatus sacralis offers a nontransmuscular alternative entry point for endoscopic approaches. In this study, we collected data about the complex anatomical conditions of the sacral canal as a basis for the development of a sacral endoscope. METHODS: We retrospectively evaluated 192 postmortem human cadaveric specimens with computed tomography (CT). The anatomical conditions of the sacrum and lumbar spine were analyzed, including assessment of the lateral and anteroposterior diameters, measurement of the cross-sectional area of the sacral canal at the lumbosacral transition, hiatus sacralis, and the narrowest point of the sacral canal. RESULTS: The narrowest anteroposterior diameter was >2.3 mm in 95% of the cases; the width was >13 mm in 95% of the cases. The narrowest point was located at the hiatus in 72% of the cases. The angle of sacral kyphosis was less than 30° and less than 50° in lumbar lordosis in 95% of the cases. A length shorter than 288 mm was measured in 95% of the cases. Anatomical conditions in male and female sacra were comparable. CONCLUSIONS: The narrow anteroposterior diameter is the key limiting feature for using the canalis sacralis as a natural entry point into the spinal canal. Sacroscopy will require endoscopes with a flattened shape, with parallel arrangement of instruments and flexibility to accommodate the varied dorsal and ventral curvatures.

6.
Am J Forensic Med Pathol ; 37(3): 214-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27454744

RESUMO

Cross-sectional imaging, such as computed tomography, has been increasingly implemented in both historic and recent postmortem forensic investigations. It aids in determining cause and manner of death as well as in correlating injuries to possible weapons. This study illuminates the feasibility of reconstructing guns in computed tomography and gives a distinct overview of historic and recent Swiss Army guns.


Assuntos
Armas de Fogo , Tomografia Computadorizada por Raios X , História do Século XX , Humanos , Processamento de Imagem Assistida por Computador , Militares , Suíça
7.
Leg Med (Tokyo) ; 20: 68-74, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27161927

RESUMO

PURPOSE: The purpose of this study was to evaluate the feasibility of diagnosing fatal pulmonary thromboembolism (PTE) with unenhanced postmortem computed tomography (PMCT). MATERIALS AND METHODS: Twelve cases with autopsy confirmed PTE and matched controls (n=19) were retrospectively examined for PTE signs on PMCT. The following variables were evaluated: edema of the lower extremities (areal and Hounsfield Unit measurements) and observer dependent patterns of the morphology of the sedimentation in the pulmonary arteries and trunk. RESULTS: The median absolute difference between the areal measurements of the right and left lower leg and thigh and the attenuation of the popliteal adipose tissue did not differ significantly between the groups. In contrast, the categorical assessment of soft tissue edema in the lower extremities was significantly different. A statistically significant difference could also be found in the shape of the vascular content within the pulmonary trunk and arteries. CONCLUSION: PTE may be assessed on unenhanced PMCT using diagnostic clues such as a distinct pattern of the pulmonary artery content and the presence of perivascular edema in the lower extremities.


Assuntos
Embolia Pulmonar/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Meat Sci ; 113: 35-40, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26610289

RESUMO

Owing to the demand for genuine mozzarella, some 330 water buffaloes are being slaughtered every year in Switzerland albeit a stunning procedure meeting animal welfare and occupational safety requirements remains to be established. To provide a basis for improvements, we sized anatomical specifics in water buffaloes and cattle and we assessed brain lesions after stunning with captive bolts or handguns by diagnostic imaging. In water buffaloes and cattle, the median distance from the frontal skin surface to the inner bone table was 74.0mm (56.0-100.0mm) vs 36.6mm (29.3-44.3mm) and from skin to the thalamus 144.8mm (117.1-172.0mm) vs 102.0 (101.0-121.0mm), respectively. Consequently, customary captive bolt stunners may be inadequate. Free bullets are potentially suitable for stunning buffaloes but involve occupational safety hazards. The results of the present study shall be used to develop a device allowing effective and safe stunning of water buffaloes.


Assuntos
Búfalos , Bovinos , Estado de Consciência/fisiologia , Imageamento por Ressonância Magnética/veterinária , Tomografia Computadorizada por Raios X/veterinária , Bem-Estar do Animal , Animais , Saúde Ocupacional
9.
Forensic Sci Med Pathol ; 11(2): 162-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25724838

RESUMO

The aim of this study was to evaluate the diagnostic criteria and to identify the radiological signs (derived from known radiological signs) for the detection of aortic dissections using postmortem computed tomography (PMCT). Thirty-three aortic dissection cases were retrospectively evaluated; all underwent PMCT and autopsy. The images were initially evaluated independently by two readers and were subsequently evaluated in consensus. Known radiological signs, such as dislocated calcification and an intimomedial flap, were identified. The prevalence of the double sedimentation level in the true and false lumen of the dissected aorta was assessed and defined as a postmortem characteristic sign of aortic dissection. Dislocated calcification was detected in 85% of the cases with aortic calcification; whereas in 54% of the non-calcified aortas, the intimomedial flap could also be recognized. Double sedimentation was identified in 16/33 of the cases. Overall, in 76% (25/33) of the study cases, the described signs, which are indicative for aortic dissection, could be identified. In this study, three diagnostic criteria of aortic dissection were identified using non-enhanced PMCT images of autopsy-confirmed dissection cases.


Assuntos
Aorta/lesões , Aortografia , Autopsia/métodos , Tomografia Computadorizada por Raios X , Sedimentação Sanguínea , Patologia Legal , Humanos , Estudos Retrospectivos , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/lesões , Túnica Média/diagnóstico por imagem , Túnica Média/lesões , Calcificação Vascular/diagnóstico por imagem
10.
Eur J Radiol ; 84(4): 643-51, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25604908

RESUMO

PURPOSE: The purpose of this study was to compare postmortem computed tomography with forensic autopsy regarding their diagnostic reliability of differentiating between pre-existing cerebral edema and physiological postmortem brain swelling. MATERIALS AND METHODS: The study collective included a total of 109 cases (n=109/200, 83 male, 26 female, mean age: 53.2 years) and were retrospectively evaluated for the following parameters (as related to the distinct age groups and causes of death): tonsillar herniation, the width of the outer and inner cerebrospinal fluid spaces and the radiodensity measurements (in Hounsfield Units) of the gray and white matter. The results were compared with the findings of subsequent autopsies as the gold standard for diagnosing cerebral edema. p-Values <0.05 were considered statistically significant. RESULTS: Cerebellar edema (despite normal postmortem swelling) can be reliably assessed using postmortem computed tomography and is indicated by narrowed temporal horns and symmetrical herniation of the cerebellar tonsils (p<0.001). There was a significant difference (p<0.001) between intoxication (or asphyxia) and all other causes of death; the former causes demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units), and the gray to white matter ratio was >1.58 when leukoencephalopathy was excluded. CONCLUSIONS: Despite normal postmortem changes, generalized brain edema can be differentiated on postmortem computed tomography, and white and gray matter Hounsfield measurements help to determine the cause of death in cases of intoxication or asphyxia. Racking the brain about feasible applications for a precise and reliable brain diagnostic forensic radiology method has just begun.


Assuntos
Edema Encefálico/diagnóstico por imagem , Patologia Legal/métodos , Mudanças Depois da Morte , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia/métodos , Encéfalo/diagnóstico por imagem , Feminino , Substância Cinzenta , Humanos , Leucoencefalopatias , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Substância Branca , Adulto Jovem
11.
Forensic Sci Med Pathol ; 10(4): 623-6, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25315842

RESUMO

PURPOSE: In forensic investigations, crime scene reconstructions are created based on a variety of three-dimensional image modalities. Although the data gathered are three-dimensional, their presentation on computer screens and paper is two-dimensional, which incurs a loss of information. By applying immersive virtual reality (VR) techniques, we propose a system that allows a crime scene to be viewed as if the investigator were present at the scene. METHODS: We used a low-cost VR headset originally developed for computer gaming in our system. The headset offers a large viewing volume and tracks the user's head orientation in real-time, and an optical tracker is used for positional information. In addition, we created a crime scene reconstruction to demonstrate the system. DISCUSSION: In this article, we present a low-cost system that allows immersive, three-dimensional and interactive visualization of forensic incident scene reconstructions.


Assuntos
Gráficos por Computador , Crime , Ciências Forenses/instrumentação , Interface Usuário-Computador , Simulação por Computador , Balística Forense/instrumentação , Humanos , Imageamento Tridimensional , Design de Software , Jogos de Vídeo
12.
Radiographics ; 34(5): 1334-43, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25110963

RESUMO

The authors present a simulation-based ultrasonographic (US) training tool that can help improve the understanding of spatial relationships in US. Use of a game controller to simulate a US probe allows examination of different virtual three-dimensional (3D) objects. These 3D objects are either completely artificial simple geometric objects (eg, spheres, tubes, and ellipsoids, or more complex combinations thereof) or derived from photographed gross anatomic data (eg, the Visible Human dataset [U.S. National Library of Medicine]) or clinical computed tomographic (CT) data. The virtual US probe allows infinitely variable real-time positioning of a "slice" that is displayed as a two-dimensional (2D) cross-sectional image and as part of a 3D view. Combining the 2D and 3D views helps elucidate the spatial relationships between a 3D object and derived 2D images. This training tool provides reliable real-time interactivity and is widely available and easily affordable, since it utilizes standard personal computer technology and off-the-shelf gaming hardware. For instance, it can be used at home by medical students or residents as a complement to conventional US training. In the future, this system could be adapted to support training for US-guided needle biopsy, with use of a second game controller to control the biopsy needle. Furthermore, it could be used as a more general interactive visualization tool for the evaluation of clinical 3D CT and magnetic resonance imaging data, allowing efficient and intuitive real-time creation of oblique multiplanar reformatted images.


Assuntos
Simulação por Computador , Instrução por Computador , Imageamento Tridimensional , Ultrassonografia , Humanos
13.
Clin Imaging ; 38(6): 850-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25168905

RESUMO

OBJECTIVES: To analyze the correlation of computed tomography (CT) perfusion parameters blood flow (BF), blood volume (BV), and mean transit time (MTT) with presurgical prostate cancer data. METHODS: Ninety-eight patients with biopsy-proven prostate cancer underwent a CT-perfusion scan of the prostate. MTT, BF, and BV were determined and correlated with prostate-specific antigen (PSA) level, tumor load and Gleason score of transrectal ultrasonography-guided biopsy specimens. RESULTS: Mean BF was 41.3 ml/100 ml*min(-1), BV 5.2 ml/100 ml, MTT 8.7 s. Moderate correlations were observed between Gleason score and BF (0.35) and between PSA and BF (0.33) and BV (0.30). CONCLUSIONS: CT-perfusion shows no valuable correlation with presurgical prostate cancer data.


Assuntos
Cuidados Pré-Operatórios/métodos , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Biópsia , Volume Sanguíneo , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Prospectivos , Próstata/irrigação sanguínea , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/sangue
14.
ISRN Radiol ; 2014: 396368, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24967295

RESUMO

Objective. To evaluate the diagnostic benefit of real-time elastography (RTE) in clinical routine. Strain indices (SI) for benign and malignant tumors were assessed. Methods. 100 patients with 110 focal breast lesions were retrieved. Patients had mammography (MG), ultrasound (US), and, if necessary, MRI. RTE was conducted after ultrasound. Lesions were assessed with BI-RADS for mammography and ultrasound. Diagnosis was established with histology or follow-up. Results. SI for BI-RADS 2 was 1.71 ± 0.86. Higher SI (2.21 ± 1.96) was observed for BI-RADS 3 lesions. SI of BI-RADS 4 and 5 lesions were significantly higher (16.92 ± 20.89) and (19.54 ± 10.41). 31 malignant tumors exhibited an average SI of 16.13 ± 14.67; SI of benign lesions was 5.29 ± 11.87 (P value <0.0001). ROC analysis threshold was >3.8 for malignant disease. Sensitivity of sonography was 90.3% (specificity 78.5%). RTE showed a sensitivity of 87.1% (specificity 79.7%). Accuracy of all modalities combined was 96.8%. In BI-RADS 3 lesions RTE was able to detect all malignant lesions (sensitivity 100%, specificity 92.9%, and accuracy 93.9%). Conclusions. RTE increased sensitivity and specificity for breast cancer detection when used in combination with ultrasound.

15.
Radiographics ; 34(3): 830-46, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24819799

RESUMO

Whole-body postmortem computed tomographic (CT) angiography is a promising new development in forensic radiology that has the potential to improve vascular and soft-tissue imaging beyond levels currently achievable with unenhanced postmortem CT. Postmortem access to the vascular system and injection of contrast medium are different from those steps in clinical (antemortem) radiology. Because there is no circulation in a corpse that could transport or dilute a contrast medium, the injection must be performed by using a roller pump to fill the vasculature (arterial and venous) with a mixture of a water-soluble iodized contrast medium and polyethylene glycol. In contrast to a classic autopsy, postmortem CT angiography is a minimally invasive procedure. It allows the diagnosis of vascular lesions without the disruption or destruction of anatomic structures, which could result in a loss of evidence in a criminal investigation. Furthermore, postmortem CT angiography facilitates the display of vascular pathologic conditions in areas that are not typically covered with autopsy alone, such as the craniocervical junction and the small pelvis. Therefore, postmortem CT angiography adds substantial value to the classic forensic autopsy; cross-sectional data can be reevaluated objectively at any time and are fully reproducible as counterexpertise, which is as useful in the fields of forensic medicine and pathology as in clinical research. Familiarity with the capabilities of postmortem CT angiography may help radiologists working with forensic cases improve their diagnostic performance.


Assuntos
Angiografia/métodos , Causas de Morte , Diagnóstico , Medicina Legal/métodos , Tomografia Computadorizada por Raios X/métodos , Ferimentos e Lesões/diagnóstico por imagem , Autopsia , Coagulação Sanguínea , Meios de Contraste , Fraturas Ósseas/diagnóstico por imagem , Máquina Coração-Pulmão , Humanos , Bombas de Infusão , Mudanças Depois da Morte , Lesões dos Tecidos Moles/diagnóstico por imagem , Lesões do Sistema Vascular/diagnóstico por imagem
16.
Invest Radiol ; 49(9): 571-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24710202

RESUMO

OBJECTIVES: The aim of this study was to assess the performance of dynamic contrast-enhanced computed tomography of the prostate in patients with biopsy-proven prostate cancer. MATERIAL AND METHODS: A total of 46 male patients (median age, 65 years; range, 49-73 years) with biopsy-proven prostate cancer underwent an en bloc computed tomography perfusion (CTP) scan of the prostate before surgery. The perfusion parameters mean transit time (MTT), blood flow (BF), and blood volume (BV), as well as the microvessel density (MVD) of surgical specimens were determined. Differences in CTP parameters and MVD among postsurgical Gleason score (sGS) and postsurgical combined Gleason grade (sGG) groups were analyzed. Spearman correlation coefficients were determined between CTP parameters and presurgical biopsy-derived Gleason score (bGS), presurgical biopsy-derived combined Gleason grade (bGG), sGS, sGG, MVD, and pathological tumor stage. A linear regression analysis was carried out for exogenous variables BF, BV, MTT, bGS, and presurgical biopsy-derived combined Gleason grade and endogenous variables sGS, sGG, MVD, and T stage. A receiver operating characteristics analysis was performed to analyze the discriminating performance of CTP parameters and bGS between intermediate- and high-grade tumors. RESULTS: The mean perfusion parameters within the prostate tissue were as follows: BF, 39.1 ± 13.4 mL/100 mL min; BV, 4.9 ± 2.4 mL/100 mL; and MTT, 8.9 ± 3.7 seconds. The mean MVD of the tumor tissue was 144.3 ± 55.6/mm. Computed tomography perfusion parameters and MVD were significantly higher in patients with high-grade tumors compared with those with intermediate-grade tumors (P < 0.01 for BF, BV, and MVD). Only BV and MVD were significantly different among sGS and sGG groups. Moderate correlations were found between BF and sGS (0.38) and between BV and sGS (0.43). Linear relations of BV to sGS and to sGG were found. Blood volume (area under the curve, 0.86) was superior to bGS (area under the curve, 0.75) in discriminating high-grade from intermediate-grade tumors. CONCLUSION: Computed tomography perfusion parameters derived by en bloc perfusion of the prostate are higher in high-grade tumors compared with intermediate-grade tumors. Blood flow and BV correlate with the definitive Gleason score. Blood volume predicts high-grade tumors better than does the Gleason score of biopsy specimens. Further studies are needed to determine a potential role for CTP in prostate cancer patients.


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Volume Sanguíneo , Meios de Contraste , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Prospectivos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/fisiopatologia , Tomografia Computadorizada por Raios X/métodos
17.
Forensic Sci Med Pathol ; 10(4): 583-606, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24723662

RESUMO

Forensic radiology is a new subspecialty that has arisen worldwide in the field of forensic medicine. Postmortem computed tomography (PMCT) and, to a lesser extent, PMCT angiography (PMCTA), are established imaging methods that have replaced dated conventional X-ray images in morgues. However, these methods have not been standardized for postmortem imaging. Therefore, this article outlines the main approach for a recommended standard protocol for postmortem cross-sectional imaging that focuses on unenhanced PMCT and PMCTA. This review should facilitate the implementation of a high-quality protocol that enables standardized reporting in morgues, associated hospitals or private practices that perform forensic scans to provide the same quality that clinical scans provide in court.


Assuntos
Osso e Ossos/diagnóstico por imagem , Odontologia Legal/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Autopsia , Causas de Morte , Odontologia Legal/normas , Humanos , Mudanças Depois da Morte , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Controle de Qualidade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/normas , Imagem Corporal Total/normas
18.
Knee ; 21(2): 415-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24503228

RESUMO

BACKGROUND: Finding the right balance between tibial coverage and minimal implant overhang is an important factor in TKA. Another significant cause of failure is component malrotation. METHODS: An average master shape of the proximal tibia at TKA resection level was calculated using fine slice computed tomographies of 117 cadaveric knees. To find out whether alternate implant contours would be necessary depending on the patient's body size, we established five subgroups to compare. CAD-Analysis was performed to simulate the overhang produced after ±4°/±7°/±10° rotation. RESULTS: A master shape for the tibial resection cut (with a 5° posterior slope, 7 mm under lateral joint line) could be determined. Neither left vs. right knee joint, nor male vs. female nor the size subdivision appears to alter the calculated master shape significantly. The optimized shape allowing for ±4° of rotational freedom was found to be the best variant. CONCLUSIONS: Valid methods have been obtained to design a two-dimensional average shape of the tibial plateau. The modifications described in this study might come in useful, when designing future implant designs. CLINICAL RELEVANCE: An optimized fit at the tibial plateau and lower rates of component malrotation may result in better outcomes after TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Ajuste de Prótese , Tíbia/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Desenho Assistido por Computador , Feminino , Humanos , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Rotação , Tíbia/diagnóstico por imagem , Adulto Jovem
19.
BMC Pediatr ; 14: 15, 2014 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-24438163

RESUMO

BACKGROUND: In light of declining autopsy rates around the world, post-mortem MR imaging is a promising alternative to conventional autopsy in the investigation of infant death. A major drawback of this non-invasive autopsy approach is the fact that histopathological and microbiological examination of the tissue is not possible. The objective of this prospective study is to compare the performance of minimally invasive, virtual autopsy, including CT-guided biopsy, with conventional autopsy procedures in a paediatric population. METHODS/DESIGN: Foetuses, newborns and infants that are referred for autopsy at three different institutions associated with the University of Zurich will be eligible for recruitment. All bodies will be examined with a commercial CT and a 3 Tesla MRI scanner, masked to the results of conventional autopsy. After cross-sectional imaging, CT-guided tissue sampling will be performed by a multifunctional robotic system (Virtobot) allowing for automated post-mortem biopsies. Virtual autopsy results will be classified with regards to the likely final diagnosis and major pathological findings and compared to the results of conventional autopsy, which remains the diagnostic gold standard. DISCUSSION: There is an urgent need for the development of alternative post-mortem examination methods, not only as a counselling tool for families and as a quality control measure for clinical diagnosis and treatment but also as an instrument to advance medical knowledge and clinical practice. This interdisciplinary study will determine whether virtual autopsy will narrow the gap in information between non-invasive and traditional autopsy procedures. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01888380.


Assuntos
Autopsia/métodos , Biópsia Guiada por Imagem , Estudos Transversais , Feto/patologia , Humanos , Lactente , Recém-Nascido , Estudos Prospectivos , Método Simples-Cego
20.
Leg Med (Tokyo) ; 15(6): 329-31, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24112989

RESUMO

We present a case of a postmortem finding of bone marrow edema in postmortem magnetic resonance imaging (PMMR) indirectly induced by a bullet, which barely missed the bone of a 92-year-old man found kneeling in front of his bed of a tidy apartment. Additionally, a selective postmortem computed tomography angiography (PMCTA) of the left leg was performed, visualizing a laceration of the left femoral vein by the bullet with consecutive contrast media extravasation. A vast pulmonary fat embolism was diagnosed and together with the blood loss found to be the cause of death.


Assuntos
Medula Óssea/patologia , Edema/patologia , Patologia Legal/métodos , Traumatismos da Perna/patologia , Ferimentos por Arma de Fogo/patologia , Idoso de 80 Anos ou mais , Angiografia/instrumentação , Angiografia/métodos , Medula Óssea/diagnóstico por imagem , Causas de Morte , Edema/diagnóstico por imagem , Embolia Gordurosa/complicações , Embolia Gordurosa/diagnóstico por imagem , Embolia Gordurosa/etiologia , Veia Femoral/diagnóstico por imagem , Veia Femoral/lesões , Patologia Legal/instrumentação , Hemorragia/complicações , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Traumatismos da Perna/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Tomografia Computadorizada por Raios X , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...