Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Healthcare (Basel) ; 11(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38132013

RESUMO

PURPOSE: Treatment of scaphoid fracture sequelae is still an unsolved problem in hand surgery. Custom-made 3D-printed titanium partial and total scaphoid prosthesis and scaphoid interosseous ligament reconstruction (SLIL) are performed in cases of non-union and isolated aseptic necrosis of the proximal scaphoid pole and when it is impossible to save the scaphoid bone, respectively. This study aims to evaluate the clinical, functional and radiographic results after these two prosthesis implantations. METHODS: Between January 2019 and July 2020, nine partial and ten total scaphoid prostheses were implanted using custom-made 3D-printed titanium implants. Evaluation criteria included carpal height ratio (CHR), radioscaphoid angle, wrist extension and flexion, radial deviation and ulnar deviation of the wrist, grip strength and pinch strength, Visual Analogue Scale (VAS), the Disabilities of Arm, Shoulder, and Hand (DASH) score, and the Patient-Rated Wrist Evaluation (PRWE). RESULTS: Clinical, functional, and radiographic improvements were found in all outcomes analyzed for both patient groups. The VAS pain scale obtained the most remarkable improvement at the one-year follow-up. The results of the DASH scores and the PRWE were good, with a great rate of patient satisfaction at the end of the follow-up. SLIL reconstruction also provided excellent stability and prevented a mid-carpal bone collapse in the short- and medium-term follow-up. CONCLUSIONS: A custom-made 3D-printed titanium partial or total scaphoid prosthesis is a viable solution for patients with scaphoid non-union and necrosis or complete scaphoid destruction in whom previous conservative or surgical treatment has failed.

2.
Indian J Orthop ; 56(6): 1040-1047, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35669017

RESUMO

Introduction: Recent innovations in wrist arthroplasty implants have led to remarkable improvements in terms of results with improved stability and preservation of bone stock. Despite the advances in such implants, poor outcomes and frequent complications still affect this procedure, not allowing a wider use of this treatment in wrist arthritis.The purpose of this study is to assess the preliminary mid-term results of a Wrist Arthroplasty System (Freedom®, Integra Lifesciences, Princeton, USA) in patients with rheumatoid arthritis or secondary osteoarthritis of the wrist and to propose a new classification system. Materials and Methods: We examined 12 patients (7 with rheumatoid arthritis and 5 with secondary osteoarthritis of the wrist) who underwent total wrist arthroplasties performed by a single surgeon using the fourth-generation prosthesis. Pre- and post-operative pain on a visual analogue score, functional parameters measured with Mayo Wrist score, patient-rated wrist evaluation score, range of motion, and radiographic analysis were collected. Results: At a mean follow-up of 48 (SD 16.9) months a significant improvement (p < 0.0001) of the mean visual analogue, Mayo and PRWE scores following total wrist arthroplasty was observed. Wrist movements improved significantly (p < 0.001). Conclusion: We achieved significant improvements in pain relief, performance, and satisfaction both in rheumatic and non-rheumatic patients, confirmed by our scoring system. Level of Evidence: Level IV, case series.

3.
J Hand Surg Am ; 47(1): 90.e1-90.e7, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34045112

RESUMO

PURPOSE: To investigate differences in pinch strength recovery among patients with first carpometacarpal joint osteoarthritis treated with either arthrodesis or suspension arthroplasty. METHODS: Thirty-seven subjects who underwent arthrodesis or suspension arthroplasty for carpometacarpal osteoarthritis were included. Force exerted during maximal voluntary contraction (MVC) in a pinch task was measured. Maximal voluntary contraction was recorded using a haptic device equipped with a load cell from which an analog signal was acquired and digitized for visual feedback. Dynamic force was assessed by a task consisting of 10 repetitions, with a target of 70% of MVC. Endurance was assessed by the length of sustained pinch task at 30% of MVC. Task performance was quantified by mean distance and offset error from the target force as error indices, and standard deviation of force was used as index of force steadiness. RESULTS: The arthrodesis group obtained considerably higher MVC values than the arthroplasty group. No notable differences were found for pinch endurance. The standard deviation for dynamic force was lower for arthroplasty, indicating greater force steadiness. CONCLUSIONS: Arthrodesis is associated with greater pinch strength. Arthroplasty is associated with better pinch precision. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Articulações Carpometacarpais , Osteoartrite , Artrodese , Artroplastia , Articulações Carpometacarpais/cirurgia , Interface Háptica , Humanos , Osteoartrite/cirurgia , Amplitude de Movimento Articular , Polegar/cirurgia
4.
J Hand Surg Asian Pac Vol ; 26(3): 345-350, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34380395

RESUMO

Background: Although hand and upper limb malformations are quite frequent, up to now very few reports have been published on epidemiology. The aim of this study is to evaluate the number of infants who presented with hand and upper limb malformations from 2010 to 2015 in Italy. Methods: A retrospective analysis of a pediatric population presenting with hand and upper extremity malformations was carried out, gathering reports achieved from eight Italian Centers of pediatric hand surgery. Other factors such as gender, date and region of birth, family distribution of malformations and associated syndromes, were analysed. Results: Out of 3,100,421 live births, 765 children presented with hand and upper limb malformations. The incidence was 2,5/10,000 live births with a predominance of males and the right side. Radial polydactyly was the anomaly with the highest percentage, closely followed by simple syndactyly, simbrachidactyly and complex syndactyly. Less common conditions were the triphalangic thumb, thumb in palm, proximal radioulnar synostosis and Sprengel deformity. Inheritance of and familial predisposition to those malformations was recorded in 25 cases, while 84 children presented with syndromes related to hand anomalies. Conclusions: In conclusion the incidence of hand and upper extremity malformations in Italy is lower than that registered in other countries. The retrospective nature of the study combined with the fact that some defects frequently evade pediatric hand surgeon consultations are some possible limitations of the study. However, our data confirmed that, in spite of the decrease in the birth rate in Italy, the trend of congenital hand disorders maintained a stable trend. We aim to integrate this study with a prospective analysis and to involve the institutional health authorities in other countries so as to register the correct incidence of hand and upper extremity defects.


Assuntos
Deformidades da Mão , Mãos , Extremidade Superior , Criança , Feminino , Mãos/cirurgia , Humanos , Lactente , Itália/epidemiologia , Masculino , Estudos Retrospectivos
5.
BMJ Case Rep ; 14(7)2021 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-34244185

RESUMO

Following wrist trauma due to a karate accident, an 18-year-old male patient developed non-union of the scaphoid with proximal pole necrosis and significant scapholunate gap from an evident scapholunate interosseous ligament (SLIL) injury. A custom-made 3D-printed titanium implant was used for scaphoid replacement and SLIL reconstruction. Good clinical and radiographic outcomes were observed at his 2-year follow-up. Custom-made 3D-printed titanium implants are thought to provide a surgical solution for patients requiring site-specific scaphoid replacement while allowing the reconstruction of the scapholunate ligament.


Assuntos
Osso Semilunar , Osso Escafoide , Adolescente , Humanos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/cirurgia , Osso Semilunar/diagnóstico por imagem , Osso Semilunar/cirurgia , Masculino , Impressão Tridimensional , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/cirurgia , Titânio , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia
6.
Artigo em Inglês | MEDLINE | ID: mdl-32002467

RESUMO

A 34-year-old male patient developed scaphoid nonunion with necrosis in both fragments. A scaphoid replacement was performed using a titanium custom-made 3D-printed implant. At 1-year follow-up, good clinical and radiographic outcome was obtained. Titanium custom-made 3D-printed implants may offer a good surgical solution for patients requiring total scaphoid replacement.

7.
Handchir Mikrochir Plast Chir ; 51(6): 440-443, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31698491

RESUMO

BACKGROUND: Authors propose a technical innovation for the remodelling of the medial femoral condyle flap (MFCF) for reconstruction of small to medium bone defects performed after the surgical treatment of a thumb osteomyelitis. MATERIALS AND METHODS: A 45 year old male had thumb proximal phalanx osteomyelitis after a crush trauma of the dominant right hand and multiple previous unsuccessful surgical attempts in other hospitals. In our centre he underwent to a two stage surgical treatment of the infection through bone and soft tissue reconstruction with a MFCF shaped in a new three dimensional (3D) approach with multiple osteotomies. RESULTS: Bone union was achieved after 30 days with a stable thumb reconstruction and good soft tissue healing. No vascular complication occurred after surgery. There was no sign of infection recurrence. CONCLUSIONS: MFCF offers a variety of options for its 3 D shaping which make it a good solution in hand surgery reconstructions after surgical excision of small and medium size bony segments.


Assuntos
Falanges dos Dedos da Mão , Osteomielite , Procedimentos de Cirurgia Plástica , Falanges dos Dedos da Mão/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteomielite/cirurgia , Retalhos Cirúrgicos , Polegar , Resultado do Tratamento
8.
Mol Clin Oncol ; 6(4): 579-582, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28413672

RESUMO

Myofibromatosis is an uncommon disorder of infancy, characterized by proliferation of myofibroblasts in solitary or multiple nodules. The clinical characteristics depend on the involved sites: Myofibromatosis may develop as a musculoskeletal form, with non-painful swellings and eventual mass effect symptoms, or as a generalized form with visceral involvement and organ failure. Prognosis and therapy vary between the abovementioned patterns. When there is no visceral involvement, the tumors may regress spontaneously; however, the visceral form may represent a lifethreatening condition with poor outcome and it requires aggressive management. Imaging assessment of disease spread is mandatory to determine diagnosis, prognosis and therapy. Due to the young age of the patients, a radiation-free evaluation is recommended. We herein describe a case of musculoskeletal myofibromatosis diagnosed in a 3-month-old male infant, investigated by serial wholebody magnetic resonance imaging (MRI) examination. The histological analysis and MRI characteristics enabled a correct diagnosis and organ involvement assessment with no radiation exposure. Moreover, whole-body MRI sequences provided a detailed evaluation of the disease within a short time frame, reducing the time of sedation, which is required to perform MRI in very young patients. Therefore, whole-body MRI was found to be accurate and safe in the diagnosis and follow-up of multicentric infantile myofibromatosis.

9.
Cancer Med ; 5(9): 2359-67, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27485192

RESUMO

The purpose of the study was to determine if abdomen/pelvis computed tomography (CT) can be safety omitted in the initial staging of a subgroup of children affected by Hodgkin Lymphoma (HL). Every participating center of A.I.E.O.P (Associazione Italiana di Ematologia ed Oncologia Pediatrica) sent local staging reports of 18F-fluorodeoxyglucose positron emission tomography (PET) and abdominal ultrasound (US) along with digital images of staging abdomen/pelvis CT to the investigation center where the CT scans were evaluated by an experienced pediatric radiologist. The local radiologist who performed the US was unaware of local CT and PET reports (both carried out after US), and the reviewer radiologist examining the CT images was unaware of local US, PET and CT reports. A new abdominal staging of 123 patients performed on the basis of local US report, local PET report, and centralized CT report was then compared to a simpler staging based on local US and PET. No additional lesion was discovered by CT in patients with abdomen/pelvis negativity in both US and PET or isolated spleen positivity in US (or US and PET), and so it seems that in the initial staging, abdomen/pelvis CT can be safety omitted in about 1/2 to 2/3 of children diagnosed with HL.


Assuntos
Abdome/patologia , Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/patologia , Pelve/patologia , Tomografia Computadorizada por Raios X , Feminino , Humanos , Linfonodos/patologia , Masculino , Imagem Multimodal , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
10.
Hand (N Y) ; 6(2): 179-84, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22654701

RESUMO

Scaphoid nonunion followed by necrosis of bone segments is a common pathologic condition for the hand surgeon, and the difficulty of its management is well known. The total titanium scaphoid replacement, although not well-described in the literature, in our experience represents a reasonable choice in the treatment of this condition. Strict patient selection is necessary to achieve good clinical results. The titanium avoids the silicone synovitis, a well-described complication of silastic implants. Furthermore, this technique permits other surgical steps in case of failure.

11.
Am J Med Genet A ; 149A(7): 1597-602, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19533787

RESUMO

Poland syndrome (PS) has been described as unilateral pectoral muscle deficiency variably associated with ipsilateral thoracic and upper limb anomalies. Bilateral hypoplasia/aplasia of the pectoralis muscle and upper limb defects in association with variable thoracic muscles, chest wall deformities and lower limb defects have been infrequently reported in the literature. We report on a 3(1/2)-year-old girl with clinical features consisting in bilateral asymmetric pectoral muscle defects (complete agenesis on the left side and agenesis of the sternocostal head on the right side), nipple hypoplasia, left rib defect, and right hand symbrachydactyly. In this study, we reviewed the bilateral features present in our patient and those described in the literature. Hypotheses explaining bilateral features in PS are reviewed.


Assuntos
Síndrome de Poland/diagnóstico , Feminino , Deformidades Congênitas da Mão , Humanos , Lactente , Músculos Peitorais/anormalidades , Síndrome de Poland/genética , Parede Torácica/anormalidades , Tórax/anormalidades
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...