Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Phys Med ; 117: 103203, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38171219

RESUMO

Setup errors are an important factor in the dosimetric accuracy of radiotherapy delivery. In this study, we investigated how rotational setup errors influence the dose distribution in volumetric modulated arc therapy (VMAT) and tangential field-in-field (FiF) treatment of left-sided breast cancer with supraclavicular lymph node involvement in deep inspiration breath hold. Treatment planning computed tomography images and radiotherapy plans of 20 patients were collected retrospectively for the study. Rotational setup errors up to 3° were simulated by rotating the planning images, and the resulting dosimetric changes were calculated. With rotational setup errors up to 3°, the median decrease of V95% to clinical target volume was less than 0.8 percentage point in both VMAT and FiF plans. The dose distribution of the heart and left anterior descending artery was more stable with respect to rotations in VMAT plans compared to FiF plans. Correction of ≥1° setup errors is recommended due to increased doses to the heart and left anterior descending artery after 1° setup errors.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Neoplasias Unilaterais da Mama/diagnóstico por imagem , Neoplasias Unilaterais da Mama/radioterapia , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Órgãos em Risco
2.
Rep Pract Oncol Radiother ; 27(5): 797-808, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523797

RESUMO

Background: In locoregional radiotherapy of breast cancer with deep inspiration breath hold (DIBH), setup accuracy may depend on hospital protocol. At present, comparison between different positioning devices is challenging due to differing hospital protocols. The aim of this study was to evaluate the setup accuracy obtained with surface-guided radiation therapy (SGRT; AlignRT®, Catalyst™) or with lasers and real-time position management (RPM™) in DIBH. Materials and methods: A total of 1692 image pairs were analyzed in three groups: positioning using AlignRT® surface guidance system (Group A, n = 45), Catalyst™ (Group C, n = 50) and conventional lasers and tattoos (Group L, n = 46). We evaluated residual errors for the bony chest wall, th1 and humeral head in kV images with laser- or SGRT-based setup with and without daily image-guided radiation therapy (IGRT). Results: Less isocenter variance was found in Group A than in Group L or C (p ≤ 0.05) and in Group C than in L (p = 0.02-0.6). With SGRT only, the smallest random rotation error was found in Group A (p = 0.01). With daily IGRT, only a small difference was found for residual errors between the groups. Conclusion: Setup with SGRT improves the isocenter reproducibility compared to lasers and RPM™. Only small differences were found in setup accuracy between the SGRT devices. Due to improved isocenter accuracy, daily orthogonal IGRT is suggested in all the groups.

3.
Med Dosim ; 47(2): 146-150, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35039223

RESUMO

Studying setup accuracy in breast cancer patients with axillary lymph node inclusion in deep inspiration breath-hold (DIBH) after patient setup with surface-guided radiotherapy (SGRT) and image-guided radiotherapy (IGRT). Breast cancer patients (N = 51) were treated (50 Gy in 25 fractions) with axillary lymph nodes within the planning target volume (PTV). Patient setup was initiated with tattoos and lasers, and further adjusted with SGRT. The DIBH guidance was based on SGRT. Orthogonal and/or tangential imaging was analyzed for residual position errors of bony landmarks, the breath-hold level (BHL), the skin outline, and the heart; and setup margins were calculated for the PTV. The calculated PTV margins were 4.3 to 6.3 and 2.8 to 4.6 mm before and after orthogonal imaging, respectively. The residual errors of the heart were 3.6 ± 2.2 mm and 2.5 ± 2.4 mm before and 3.0 ± 2.5 and 2.9 ± 2.3 mm after orthogonal imaging in the combined anterior-posterior/lateral and the cranio-caudal directions, respectively, in tangential images. The humeral head did not benefit from daily IGRT, but SGRT guided it to the correct location. We presented a slightly complicated but highly accurate workflow for DIBH treatments. The residual position errors after both SGRT and IGRT were excellent compared to previous literature. With well-planned SGRT, IGRT brings only slight improvements to systematic accuracy. However, with the calculated PTV margins and the number of outliers, imaging cannot be omitted despite SGRT, unless the PTV margins are re-evaluated.


Assuntos
Neoplasias da Mama , Radioterapia Guiada por Imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Suspensão da Respiração , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia Guiada por Imagem/métodos
4.
Rep Pract Oncol Radiother ; 26(4): 545-552, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434570

RESUMO

BACKGROUND: Setup accuracy within adjuvant radiotherapy of breast cancer treated in free breathing is well studied, but a comparison of the typical regions of interest (ROI) used in surface guided radiation therapy (SGRT) does not exist. The aim of this study was to estimate the setup accuracy obtained with differently shaped ROIs in SGRT. MATERIALS AND METHODS: A total of 573 orthogonal image pairs were analyzed from free breathing breast patients in two groups: positioning using AlignRT® surface guidance system (Group A, n = 20), and setup using conventional laser and tattoo setup (Group L, n = 20). For SGRT, three different setup ROIs were used: a Breast-shaped, O-shaped and T-shaped (B-O and T-ROI). We evaluated the isocenter-, rotation-, pitch and arm position accuracy and residual errors for the chest wall and shoulder joint in kV orthogonal and tangential setup images with laser- or SGRT-based setup. RESULTS: Less isocenter variance was found in Group A than in Group L. Rotations and posture errors were larger in group L than in Group A (p ≤ 0.05). Rotation error was smaller with T-shaped ROI than with O- or B-shape (p = 0.01-0.04). CONCLUSION: Setup with AlignRT® improves reproducibility compared to laser setup. Between the different ROI shapes only small differences were found in the patient posture or the isocenter position in the images. The T-ROI is recommended to set up the chest wall bony structure and an additional B-ROI may be used to fine-tune the soft tissue accuracy.

5.
Med Dosim ; 46(3): 212-218, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33349518

RESUMO

The aim of this study was to investigate prostate radiotherapy techniques for the patients with hip prosthesis in 4 different field setups. Volumetric Modulated Arc Therapy (VMAT) technique was used in 4 different cases: (1) using full VMAT arcs (VMAT_F); (2) same arcs as in case 1 but with avoidance sectors (VMAT_ASEC); (3) as case 2 but with the addition of a lateral static field through the prosthesis (VMAT_ASEC+STAT); (4) as in case 1 but with an automated structure avoidance option to avoid irradiation through the prosthesis (VMAT_ASTR). Fifteen previously treated prostate patients were retrospectively selected to this study. Treatment plans were created for all patients using all 4 techniques. The potential prosthesis misalignment in the treatment setup was modeled by moving the prosthesis 0.5, 1.0, and 1.5 cm ventrally and dorsally and recalculating the plans in each case. For VMAT_ASEC, the dose parameters for organs at risk were the highest and the dose coverage of the target volume was the poorest when compared to the other techniques. For VMAT_ASEC+STAT, the movement of the prosthesis changed the target dose distribution the most. VMAT_F and VMAT_ASTR fulfilled the planning criteria the best, even when the prosthesis was misaligned. VMAT_F radiated through the prosthesis more than VMAT_ASTR and increased the dose near the prosthesis surface when compared to VMAT_ASTR. VMAT_ASTR and VMAT_F were the most robust techniques for the patients with the hip prosthesis considering plan quality and the effect of positioning errors. The increased prosthesis surface dose with VMAT_F and possible dose calculation uncertainties favors the use of VMAT_ASTR.


Assuntos
Prótese de Quadril , Radioterapia de Intensidade Modulada , Humanos , Masculino , Próstata , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
6.
Med Dosim ; 46(1): 86-93, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32994095

RESUMO

To investigate the near-surface doses and target coverage in modulated arc radiotherapy (RT) of the breast or chest wall in two treatment planning systems (TPS) in the presence of soft tissue deformations. This retrospective study consisted of 10 breast cancer patients with axillary lymph node inclusion. For each case, five RT plans were created: (1) tangential 3D conformal field-in-field (FinF) technique; (2) 200° to 240° arcs with optimization bolus (OB) in Eclipse (EB); (3) 243° to 250° arcs with an 8-mm OB in Monaco (MB); (4) 243° to 250° arcs with automatic skin flash tool (ASF) in Monaco TPS (MA); (5) 243° to 250° arcs with both ASF and OB in Monaco (MAB). Soft tissue deformation was simulated by editing CT-images with 4-, 8-, and 12-mm swelling and recalculating the dose. The increasing swelling from 0 to 12 mm caused the coverage (V95%) in clinical target volume to decrease from 96% ± 2% to 90% ± 6% for the FinF plans. For volumetric-modulated arc therapy (VMAT), the coverage decreased from 99% ± 1% to 92% ± 4% in the EB plans, and from 97% ± 1% to 68% ± 8%, 85% ± 6%, and 86% ± 5% for MA, MB, and MAB, respectively. The mean dose in the surface extending from 0 to 3 mm from the skin decreased on average 5%, 17%, 20%, 15%, and 8% in FinF, EB, MA, MB, and MAB, respectively. In the Monaco plans, the use of an OB(+ASF) provided better target coverage and lower dose maxima despite of tissue swelling than the ASF alone. With modulated arc therapy, we recommend the use of an OB instead of or in addition to the ASF. The use of 8 mm OB with VMAT plans is robust to account deformations extending outside up to 8mm. If soft tissue deformation is larger than 8 mm, the need for replanning should be evaluated.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Neoplasias da Mama/radioterapia , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
7.
J Appl Clin Med Phys ; 20(3): 97-104, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30861276

RESUMO

PURPOSE: Surface guided radiotherapy (SGRT) is reported as a feasible setup technique for whole-breast radiotherapy in deep inspiration breath hold (DIBH), but position errors of bony structures related to deeper parts of the target are not fully known. The aim of this study was to estimate patient setup accuracy and margins obtained with two different SGRT workflows with and without daily kV- and/or MV-based image guidance (IGRT). METHODS: A total of 50 breast cancer patients were treated in DIBH, using SGRT for the patient setup, and IGRT for isocenter corrections. The patients were treated at two different departments, one using AlignRT® (25 patients) and the other using Catalyst™ (25 patients). Inter-fractional position errors were analyzed retrospectively in orthogonal and tangential setup images, and analyzed with and without IGRT. RESULTS: In the orthogonal kV-kV images, the systematic residual errors of the bony structures were ≤ 3 mm in both groups with SGRT-only. When fine-adjusted by daily IGRT, the errors decreased to ≤ 2 mm; except for the shoulder joint. The residual errors of the ribs in tangential images were between 1 and 2 mm with both workflows. The heart planning margins were between 3 and 7 mm. CONCLUSIONS: The frequency of IGRT may be considerably reduced with a well-planned SGRT-workflow for whole-breast DIBH with residual errors ≤ 3 mm. This accuracy can be further improved with an IGRT scheme.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Suspensão da Respiração , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
8.
Med Dosim ; 44(2): 117-121, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29681424

RESUMO

The objective of this study was to modify volumetric modulated arc therapy (VMAT) design for breast irradiation with axillary lymph node involvement to enhance normal tissue sparing while maintaining good planning target volume (PTV) coverage. Four VMAT plans were generated retrospectively for 10 patients with breast cancer for comparison. First, 2 partial arcs with an avoidance sector (Pavoid) for the lung and the heart were created. Second, a split-arc design with 2 partial arcs was used, changing the collimator angle by splitting the arcs in the middle, resulting in 4 partial arcs (Psplit). Third, the arc angles in the Psplit were modified to emphasize tangential directions, corresponding to the avoidance sector in Pavoid, resulting in 2 lateral and 2 anterior partial arcs. Furthermore, a fifth arc was added to ensure the coverage of axillary lymph nodes (Ptang). Fourth, one of the anterior arcs was removed to limit the number of arcs during treatment (Ptang-1). PTV coverage was the highest in Psplit with a V90%(PTV) of 98.4 ± 0.6%. Also the dose homogeneity and conformity were the best (p < 0.02) in Psplit, and a smaller high-dose volume was distributed to the ipsilateral lung, heart, and humeral head, than in the other designs. In Ptang and Ptang-1, the PTV coverage was acceptable with V90%(PTV) of 97.9 ± 0.8% and 98.0 ± 0.8%, respectively, and low-dose volumes in normal tissue were smaller compared with Psplit. The removal of 1 partial arc from Ptang (Ptang-1) did not have a significant effect on dose parameters. In Pavoid, the contralateral breast and lung volumes of low-dose level were the smallest. However, the PTV coverage was reduced (V90% = 97.0 ± 1.6%), and the heart, ipsilateral lung, and humeral head received significantly higher doses than in other designs. The modified split-arc methods Ptang and Ptang-1, emphasizing tangential directions, were close to the original split-arc method in PTV coverage while reducing the dose to the healthy tissues distant from the PTV. Ptang-1 is seen as a favorable treatment option over Ptang with less treatment time.


Assuntos
Neoplasias da Mama/terapia , Tratamentos com Preservação do Órgão , Radioterapia de Intensidade Modulada , Idoso , Axila , Neoplasias da Mama/patologia , Feminino , Humanos , Linfonodos , Mastectomia , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Radioterapia Adjuvante , Estudos Retrospectivos
9.
Med Dosim ; 44(3): 266-273, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30389413

RESUMO

The aim of this study was to find an optimal optimization skin flash thickness in volumetric modulated arc radiotherapy of the breast in consideration of soft tissue deformations during the treatment course. Ten breast radiotherapy patients with axillary lymph node inclusion were retrospectively planned with volumetric modulated arc radiotherapy technique. The plans were optimized with the planning target volume (PTV) extending outside the skin contour by 0, 5, 7, and 10 mm; and with optimization boluses of 3 or 5 mm on the extended PTV. The final dose was calculated without the bolus. The plans were compared in terms of PTV homogeneity and conformity, and dose minima and maxima. The doses to organs at risk were also evaluated. The doses were recalculated in real patient geometries based on cone beam computed tomography (CBCT) images captured 3 to 6 times during each patient's treatment course. The optimization to the PTV without the PTV extension resulted in the best CTV coverage in the original plans (V95% = 98.0% ± 1.2%). However, when these plans were studied in real CBCT-based patient geometries, the CTV V95% was compromised (94.6% ± 8.3%). In addition, for the surface (4 mm slap inside the PTV 4 mm below the body contour) dose V95% was reduced from the planned 74.7% ± 7.5% to the recalculated 65.5% ± 11.5%. Optimization with an 8-mm bolus to a PTV with 5-mm extension was the most robust choice to ensure the CTV and surface dose coverage (recalculated V95% was 95.2% ± 6.4% and 74.6% ± 8.4%, respectively). In cases with the largest observed deformations, even a 10-mm PTV extension did not suffice to cover the target. Optimization with a 5-mm PTV extension and an 8-mm optimization bolus improved the surface dose and slightly improved the CTV dose when compared to no extension plans. For deformations over 1 cm, no benefit was seen in PTV extensions and replanning is recommended. Frequent tangential and CBCT imaging should be used during treatment course to detect potential large anatomical changes.


Assuntos
Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos
10.
Phys Med ; 55: 82-87, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30471824

RESUMO

OBJECTIVES: To investigate the dosimetric effect of air gaps under bolus on skin dose for left-sided post-mastectomy radiotherapy with loco regional involvement. METHODS: Eight patients were planned retrospectively with volume modulated arc therapy (VMAT) and conventional static Field-in-Field (FinF) methods. Three different setups were applied for the 5-mm bolus over the chest wall having 0, 5 or 10 mm air gap under the bolus. The dose calculation was performed using Monte Carlo (MC) simulation. In addition, Analytic Anisotropic Algorithm (AAA) was used to demonstrate the differences observed in clinical setting. RESULTS: The investigated air gaps under the bolus had minimal effect on surface dose for FinF plans (relative difference ≤ 2.6%), whereas for VMAT plans the surface dose decreased 13.6% when compared to the case with no air gap. In both FinF and VMAT, the largest differences between AAA and MC were seen at the surface where AAA underestimated the dose by 1.5 Gy (p < 0.05) on average; while the dose in the target volume excluding the surface was relatively similar being on average 0.3 Gy (p > 0.05) larger with AAA than with MC calculations. CONCLUSIONS: The surface dose was significantly lower with VMAT technique than with FinF technique. Possible air gaps under the bolus reduced the surface dose significantly further for VMAT but not for FinF treatments, which may have clinical impact on recurrence rate. AAA was shown to underestimate the surface dose when compared to MC calculation.


Assuntos
Ar , Mastectomia , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Artefatos , Humanos , Dosagem Radioterapêutica
11.
J Appl Clin Med Phys ; 19(5): 506-516, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29978548

RESUMO

AIM: Traditional radiotherapy treatment techniques of the breast are insensitive for deformations and swelling of the soft tissue. The purpose of this study was to evaluate the dose changes seen with tissue deformations using different image matching methods when VMAT technique was used, and compare these with tangential technique. METHODS: The study included 24 patients with breast or chest wall irradiations, nine of whom were bilateral. In addition to planar kV setup imaging, patients underwent weekly cone-beam computed tomography (CBCT) imaging to evaluate soft tissue deformations. The effect of the deformations was evaluated on VMAT plans optimized with 5-mm virtual bolus to create skin flash, and compared to standard tangential plans with 2.5 cm skin flash. Isocenter positioning using 2D imaging and CBCT were compared. RESULTS: With postural changes and soft tissue deformations, the target coverage decreased more in the VMAT plans than in the tangential plans. The planned V90% coverage was 98.3% and 99.0% in the tangential and VMAT plans, respectively. When tattoo-based setup and online 2D match were used, the coverage decreased to 97.9% in tangential and 96.5% in VMAT plans (P < 0.001). With automatic CBCT-based image match the respective coverages were 98.3% and 98.8%. In the cases of large soft tissue deformations, the replanning was needed for the VMAT plan, whereas the tangential plan still covered the whole target volume. CONCLUSIONS: The skin flash created using an optimization bolus for VMAT plans was in most cases enough to take into account the soft tissue deformations seen in breast VMAT treatments. However, in some cases larger skin flash or replanning were needed. The use of 2D match decreased the target coverage for VMAT plans but not for FinF plans when compared to 3D match. The use of CBCT match is recommended when treating breast/chest wall patients with VMAT technique.


Assuntos
Neoplasias da Mama/radioterapia , Radiometria , Mama , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
12.
Phys Med ; 44: 11-17, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29254586

RESUMO

PURPOSE: To investigate the use of dual isocenters for VMAT planning in patients with lymph node positive synchronous bilateral breast cancer (BBC) compared to a single isocenter option. METHODS: Treatment plans of 11 patients with lymph node positive BBC were retrospectively analyzed using two different VMAT planning techniques: dual-isocenter split-arc VMAT plans (Iso2) were compared with mono-isocenter VMAT plans (Iso1). For Iso2 plans, PTV dose was investigated after introducing ±2 and ±5 mm couch shift errors between the two isocenters in the lateral, longitudinal and vertical direction. RESULTS: For both techniques the planning aims for PTV coverage and OARs were met. The mean dose for the bilateral lungs and heart was reduced from 11.3 Gy and 3.8 Gy to 10.9 Gy (p < .05) and 3.6 Gy (p < .05), respectively, for Iso2 plans when compared to Iso1 plans. Positive statistically significant correlation (rho = 0.76, p = .006) was found between PTV volume and D2ccPTV for Iso1 plans. No clinically significant change was seen in the D98CTV or D2ccPTV after the 2 and 5 mm errors were introduced between isocenters for Iso2 plans. CONCLUSIONS: The split arc method was shown to be a feasible treatment technique in the case of synchronous BBC for both mono and dual isocenter techniques. The dose parameters were slightly favoring dual-isocenter option instead of mono-isocenter. The dual-isocenter method was shown to be a robust treatment option in the presence of ≤5 mm errors in the shifts between the two isocenters.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada , Neoplasias da Mama/diagnóstico por imagem , Humanos , Metástase Linfática , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
Phys Med ; 2016 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-28029580

RESUMO

PURPOSE: To investigate different volumetric modulated arc therapy (VMAT) field designs for lymph node positive breast cancer patients when compared to conventional static fields and standard VMAT designs. METHODS: Nineteen breast cancer patients with lymph node involvement (eleven left and eight right sided) were retrospectively analyzed with different arc designs. Proposed split arc designs with total rotations of 2×190° and 2×240° were compared to conventional field in field (FinF) and previously published non-split arc techniques with the same amount of total rotations. RESULTS: All VMAT plans were superior in dose conformity, when compared to the FinF plans. Split arc design decreased significantly ipsilateral lung dose and heart V5Gy for both left and right sided cases, when compared to non-split VMAT designs. For left sided cases no significant differences were seen in contralateral lung mean dose or V5Gy between different VMAT designs. For right sided cases the contralateral lung dose V5Gy was significantly higher in split VMAT group, when compared to non-split VMAT designs. The contralateral breast dose V5Gy increased significantly for split VMAT plans for both sides, when compared to non-split VMAT designs or FinF plans. CONCLUSIONS: The proposed split VMAT technique was shown to be superior to previously published non-split VMAT and conventional FinF techniques significantly reducing dose to the ipsilateral lung and heart. However, this came with the expense of an increase in the dose to the contralateral breast and for right-sided cases to the contralateral lung.

14.
J Appl Clin Med Phys ; 17(4): 73-85, 2016 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-27455479

RESUMO

The aim of this study was to find optimal planning approach for large planning targets with complicated geometry requiring wide field openings. The study presents a novel approach for arc geometry design for pelvic targets with extensive nodal involvement. A total of 15 patients with anorectal carcinoma or vulvar cancer were selected retrospectively. For each patient, one seven-field IMRT plan and three VMAT plans were calculated: one with two 360° arcs with no limitations for the field size (VMATw); one with two asymmetrically field-size-restricted 360° arcs (VMATr); and the proposed novel approach which consisted of one 360° arc with the field size restricted to the central PTV, and another arc divided into two 180° arcs, restricting the field sizes with the focus on the lymph nodes. The techniques were compared in terms of PTV coverage (VPTV(95%)), dose maximum (D(max)), dose conformity index (CI), homogeneity index (HI), and organs at risk doses. The proposed novel approach with one full and two half arcs tended to have better PTV coverage (VPTV(95%) = 97% ± 2%, compared to 95% ± 3%, 95% ± 3%, and 97% ± 2% in VMATw, VMATr, and 7f-IMRT, respectively) and lower maxima (D(max) = 107% ± 1%, compared to 110% ± 3%, 110% ± 4%, and 110% ± 4% in VMATw, VMATr, and 7f-IMRT, respectively); and lower or equal organs at risk doses. The superiority of the proposed technique (CI = 1.16 ± 0.05, HI = 9 ± 2) was more pronounced compared with the VMATw plans (CI = 1.41 ± 0.10, paired t-test p < 0.001; HI = 12 ± 2, p < 0.001), but the proposed technique was slightly better also in comparison with the VMATr plans (CI = 1.21 ± 0.07, p < 0.001; HI= 11 ± 4, p = 0.015) and 7f-IMRT plans (CI = 1.18 ± 0.03, p = 0.016; HI = 10 ± 2, p = 0.215). Radiotherapy treatment planning for large and complicated treatment volumes benefits not only from restricting the field size but also from careful field design that considers PTV geometry. This optimizes multileaf collimator movements, leading to better dose conformity and homogeneity.


Assuntos
Linfonodos/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Pelve/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Doenças Retais/radioterapia , Neoplasias Vulvares/radioterapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos
15.
Clin Imaging ; 39(2): 207-12, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25487438

RESUMO

The potential of diffusion tensor imaging (DTI) indices and volumes of focal lesions on conventional magnetic resonance imaging to predict conversion to multiple sclerosis (MS) was analyzed in subjects with clinically isolated syndrome (CIS) over 4 years. Twenty patients with CIS and 10 healthy controls were included in the study. The data showed an association between the volumes of T1 and fluid-attenuated inversion recovery (FLAIR) lesions and conversion to MS (T1: P=.02; FLAIR: P=.02). The worsening of DTI indices (mean diffusivity and fractional anisotropy) was primarily seen in patients progressing to MS, but clear-cut association with conversion could not be detected.


Assuntos
Encéfalo/patologia , Doenças Desmielinizantes/diagnóstico , Imagem de Tensor de Difusão , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico , Substância Branca/patologia , Adulto , Anisotropia , Encéfalo/fisiopatologia , Doenças Desmielinizantes/patologia , Doenças Desmielinizantes/fisiopatologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Esclerose Múltipla/fisiopatologia , Substância Branca/fisiopatologia , Adulto Jovem
16.
Acad Radiol ; 21(1): 64-71, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24331266

RESUMO

RATIONALE AND OBJECTIVES: The aim of this study was to examine changes of brain iron content and diffusion patterns longitudinally in early-stage Parkinson's disease (PD) patients using T2- and T2*-based magnetic resonance imaging (MRI) over 2-year follow-up. MATERIALS AND METHODS: We imaged 32 PD patients with tremor and 19 healthy controls. A follow-up study (median 25 months, range 22-31 months) was accomplished for 25 patients (men:women = 11:14; age range 44-87 years, median 73 years). All patients and healthy volunteers underwent clinical, neuropsychological, and MRI examinations on the same day. Three different MRI sequences were used and their results were compared: T2-weighted imaging, susceptibility-weighted imaging, and T2* mapping. Additionally, we evaluated diffusion tensor data between groups using tract-based spatial statistics. RESULTS: Over the 2-year follow-up, the iron-related relaxation increased in the globus pallidus anterior and the caudate nucleus and slightly in the substantia nigra pars compacta (SNc). In the globus pallidus anterior and medial SNc, the change was associated with mild cognitive impairment. In the caudate nucleus, the increase was pronounced in patients with disease onset at 67 years or older. In the SNc, medial transverse relaxation was increased, and in the thalamus, it was decreased, in patients with PD compared with healthy volunteers at 2-year follow-up. Tract-based spatial statistical data did not differ between groups based on gender or Unified Parkinson's Disease Rating Scale, but a slight tendency to decreasing fractional anisotropy (P < .10) in the genu of corpus callosum and bilaterally in corona radiata was seen over 2 years. CONCLUSIONS: PD-related changes were found in putative iron content over 2 years. Although mild in the initial stages, these changes were consistent over MRI sequences. Rather than correlating with disease duration, the rate of changes was associated with individual characters, such as cognitive decline and age.


Assuntos
Encéfalo/metabolismo , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Ferro/metabolismo , Doença de Parkinson/metabolismo , Doença de Parkinson/patologia , Adulto , Idoso , Anisotropia , Biomarcadores/metabolismo , Núcleo Caudado/metabolismo , Diagnóstico Precoce , Feminino , Seguimentos , Globo Pálido/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tálamo/metabolismo , Distribuição Tecidual
17.
Clin Imaging ; 37(4): 631-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23522789

RESUMO

We studied nonheme iron in Parkinson's disease (PD) using clinically available MRI in 36 patients and 21 healthy volunteers. The subjects underwent thorough clinical investigation, including 3-T MRI. Quantitative R2* was able to reflect symptoms of PD. In addition, the clinically used susceptibility-weighted imaging differentiated between controls and patients, whereas T2-weighted imaging did not. Disease-related changes were present not only in substantia nigra but also in globus pallidus. Such changes are associated with neurodegeneration, reflecting the severity of motor impairment.


Assuntos
Globo Pálido/química , Globo Pálido/patologia , Ferro/análise , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/diagnóstico , Substância Negra/química , Substância Negra/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Mapeamento Encefálico/métodos , Núcleo Caudado/química , Núcleo Caudado/patologia , Corpo Caloso/química , Corpo Caloso/patologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Mult Scler Int ; 2013: 265259, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24455265

RESUMO

The aim of this study was to evaluate diffusion tensor imaging (DTI) indices in the corpus callosum and pyramidal tract in normal-appearing white matter (NAWM) and the caudate nucleus and thalamus in deep grey matter (NADGM) in all MS subtypes and clinically isolated syndrome (CIS). Furthermore, it was determined whether these metrics are associated with clinical measures and the serum levels of candidate immune biomarkers. Apparent diffusion coefficients (ADC) values were significantly higher than in controls in all six studied NAWM regions in SPMS, 4/6 regions in RRMS and PPMS and 2/6 regions in CIS. In contrast, decreased fractional anisotropy (FA) values in comparison to controls were detected in 2/6 NAWM regions in SPMS and 1/6 in RRMS and PPMS. In RRMS, the level of neurological disability correlated with thalamic FA values (r = 0.479, P = 0.004). In chronic progressive subtypes and CIS, ADC values of NAWM and NADGM were associated with the levels of MIF, sFas, and sTNF- α . Our data indicate that DTI may be useful in detecting pathological changes in NAWM and NADGM in MS patients and that these changes are related to neurological disability.

19.
Acta Radiol ; 52(9): 995-1002, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21948597

RESUMO

BACKGROUND: Computed tomography (CT) is generally used in the evaluation of the treatment response of non-Hodgkin's lymphoma (NHL) patients. Instead of morphological images, positron emission tomography (PET) shows metabolic information that is connected to tumor activity, cell proliferation rate, and, thus, prognosis. PURPOSE: To determine the prognostic value of PET for tumor volume reduction measured by CT and magnetic resonance imaging (MRI) along with clinical characteristics in NHL patients. MATERIAL AND METHODS: We imaged 21 B-cell type NHL patients using whole-body 18F-FDG-PET at the onset and the completion of treatment and at six-month follow-up. The maximum standardized uptake value (SUV(max)) was calculated. Morphological tumor volume calculations were assessed using both MRI and CT. Additionally, patients underwent thorough clinical examination including several laboratory tests. RESULTS: A high SUV(max) was able to predict significant tumor volume reduction at the beginning of treatment, but the relation to pure tumor volume was poor. CONCLUSION: The SUV(max) values derived from FDG-PET seemed to correlate with volume changes but not with their absolute values or laboratory tests. Unlike MRI and CT, FDG-PET showed the disappearance of active tumors after treatment.


Assuntos
Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/patologia , Tomografia por Emissão de Pósitrons , Carga Tumoral , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prognóstico , Tomografia Computadorizada por Raios X
20.
Acad Radiol ; 18(10): 1217-24, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21784670

RESUMO

RATIONALE AND OBJECTIVES: Early-stage diagnosis of Parkinson's disease (PD) is essential in making decisions related to treatment and prognosis. However, there is no specific diagnostic test for the diagnosis of PD. The aim of this study was to evaluate the role of texture analysis (TA) of magnetic resonance images in detecting subtle changes between the hemispheres in various brain structures in patients with early symptoms of parkinsonism. In addition, functional TA parameters for detecting textural changes are presented. MATERIALS AND METHODS: Fifty-one patients with symptoms of PD and 20 healthy controls were imaged using a 3-T magnetic resonance device. Co-occurrence matrix-based TA was applied to detect changes in textures between the hemispheres in the following clinically interesting areas: dentate nucleus, basilar pons, substantia nigra, globus pallidus, thalamus, putamen, caudate nucleus, corona radiata, and centrum semiovale. The TA results were statistically evaluated using the Mann-Whitney U test. RESULTS: The results showed interhemispheric textural differences among the patients, especially in the area of basilar pons and midbrain. Concentrating on this clinically interesting area, the four most discriminant parameters were defined: co-occurrence matrix correlation, contrast, difference variance, and sum variance. With these parameters, differences were also detected in the dentate nucleus, globus pallidus, and corona radiata. CONCLUSIONS: On the basis of this study, interhemispheric differences in the magnetic resonance images of patients with PD can be identified by the means of co-occurrence matrix-based TA. The detected areas correlate with the current pathophysiologic and neuroanatomic knowledge of PD.


Assuntos
Encéfalo/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/patologia , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...