J Clin Med ; 11(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36294304

RESUMO

PURPOSE: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. METHODS: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. RESULTS: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. CONCLUSIONS: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.

2.
Vet Radiol Ultrasound ; 45(6): 513-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15605840

RESUMO

Magnetic resonance imaging (MRI) of the distal extremities of the standing, sedated horse would be desirable if diagnostic quality images could be obtained. With the availability of extremity and special purpose magnet designs on the market, a system to safely accommodate the standing horse may gain increasing popularity. This paper considers the issue of motion that will need to be addressed to achieve successful, diagnostic quality images. The motion of the carpus and tarsus of five standing, sedated horses was quantified. The obtained motion records were then used to induce motion in cadaveric joint specimens during several MRI scans. The measured dorsal-palmar/plantar, medial-lateral, and proximal-distal random wobbling motions in the standing sedated horse were several centimeters in magnitude and generated severe motion-artifacts during axial MRI of the cadaveric specimens. Two retrospective motion-correction techniques (autocorrection and navigator-based adaptive correction) were used to correct the corrupted images. The motion artifacts were nearly eliminated with the use of both techniques in series. Although significant hurdles remain, these results suggest promise for allowing diagnostic quality MRI of the carpus and tarsus in the standing horse.


Assuntos
Carpo Animal/fisiologia , Cavalos/fisiologia , Imageamento por Ressonância Magnética/veterinária , Movimento (Física) , Tarso Animal/fisiologia , Animais , Processamento de Imagem Assistida por Computador , Postura , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...