Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 59(9): 2650-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22829360

RESUMO

Automated extraction of quantitative parameters from cardiac magnetic resonance images is crucial for the management of patients with myocardial infarct. This paper proposes a postprocessing procedure to jointly analyze Cine and delayed-enhanced (DE) acquisitions, in order to provide an automatic quantification of myocardial contraction and enhancement parameters and a study of their relationship. For that purpose, the following processes are performed: 1) DE/Cine temporal synchronization and 3-D scan alignment, 2) 3-D DE/Cine rigid registration in a region about the heart, 3) myocardium segmentation on Cine-MRI and superimposition of the epicardial and endocardial contours on the DE images, 4) quantification of the myocardial infarct extent (MIE), 5) study of the regional contractile function using a new index, the amplitude to time ratio (ATR). The whole procedure was applied to ten patients with clinically proven myocardial infarction. The comparison between the MIE and the visually assessed regional function scores demonstrated that the MIE is highly related to the severity of the wall motion abnormality. In addition, it was shown that the newly developed regional myocardial contraction parameter (ATR) decreases significantly in delayed enhanced regions. This largely automated approach enables the combined study of regional MIE and left ventricular function.


Assuntos
Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Modelos Cardiovasculares , Contração Miocárdica/fisiologia , Infarto do Miocárdio/fisiopatologia , Adulto , Idoso , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Função Ventricular Esquerda/fisiologia
2.
Magn Reson Med ; 49(4): 731-42, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12652545

RESUMO

A method for reconstructing magnetic resonance angiography (MRA) volumes from successive acquisitions is described. The method is based on double oblique acquisitions of highly anisotropic MRA volumes, each of which corresponds to reduced k-space filling. These partial k-spaces are then combined to obtain a 3D k-space adapted to the frequency spread of the angiographic image of the stenosis. The SNR-resolution compromise of MRA is thus improved by focusing the acquisition on the most relevant k-space regions. The reconstruction is performed directly in k-space by averaging the partial k-spaces. The feasibility of the method was demonstrated in studies on a Lucite stenosis phantom, on MRAs of carotid arteries using three bolus injections, and on MRAs of renal arteries using a single contrast injection.


Assuntos
Artérias Carótidas/patologia , Doenças das Artérias Carótidas/patologia , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Obstrução da Artéria Renal/patologia , Artéria Renal/patologia , Meios de Contraste , Humanos , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...