Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Public Health Res Pract ; 34(1)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37517813

RESUMO

AIM: Prescribed burning is the most common method employed to reduce fuel loads in flammable landscapes. This practice is designed to reduce the hazard associated with uncontrolled bushfires. Prescribed burns are frequently conducted close to residential areas, and the associated smoke impacts can adversely affect community health. Particulate matter is the predominant pollutant within the smoke and is strongly and consistently linked with adverse health effects. Outdoor smoke readily infiltrates buildings and reduces the quality of indoor air. Portable air cleaners containing high-efficiency particulate air (HEPA) filters are a promising indoor air quality intervention for reducing outdoor smoke exposure. METHODS: We provided 10 homes from semirural regions of Victoria, Australia, with HEPA cleaners and conducted continuous monitoring of indoor and outdoor fine particulate matter (PM2.5) for 2-4 weeks during prescribed burning periods. We calculated the potential improvements to indoor air quality when operating a HEPA cleaner during a smoke episode. Ventilation measures were conducted to identify points of smoke ingress and housing characteristics that could lead to higher infiltration rates. RESULTS: Depending on the house, the use of HEPA cleaners resulted in a reduction in indoor PM2.5 concentrations of 30-74%. CONCLUSIONS: HEPA cleaners have the potential to substantially improve indoor air quality during episodic smoke episodes.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Humanos , Fumaça/efeitos adversos , Fumaça/análise , Poluentes Atmosféricos/efeitos adversos , Filtração , Biomassa , Poluição do Ar em Ambientes Fechados/efeitos adversos , Poluição do Ar em Ambientes Fechados/prevenção & controle , Poluição do Ar em Ambientes Fechados/análise , Material Particulado/efeitos adversos , Vitória , Monitoramento Ambiental
2.
Artigo em Inglês | MEDLINE | ID: mdl-33924413

RESUMO

During extreme air pollution events, such as bushfires, public health agencies often recommend that vulnerable individuals visit a nearby public building with central air conditioning to reduce their exposure to smoke. However, there is limited evidence that these "cleaner indoor air shelters" reduce exposure or health risks. We quantified the impact of a "cleaner indoor air shelter" in a public library in Port Macquarie, NSW, Australia when concentrations of fine particulate matter (PM2.5) were elevated during a local peat fire and nearby bushfires. Specifically, we evaluated the air quality improvements with central air conditioning only and with the use of portable high efficiency particulate air (HEPA) filter air cleaners. We measured PM2.5 from August 2019 until February 2020 by deploying pairs of low-cost PM2.5 sensors (i) inside the main library, (ii) in a smaller media room inside the library, (iii) outside the library, and (iv) co-located with regulatory monitors located in the town. We operated two HEPA cleaners in the media room from August until October 2019. We quantified the infiltration efficiency of outdoor PM2.5 concentrations, defined as the fraction of the outdoor PM2.5 concentration that penetrates indoors and remains suspended, as well as the additional effect of HEPA cleaners on PM2.5 concentrations. The infiltration efficiency of outdoor PM2.5 into the air-conditioned main library was 30%, meaning that compared to the PM2.5 concentration outdoors, the concentrations of outdoor-generated PM2.5 indoors were reduced by 70%. In the media room, when the HEPA cleaners were operating, PM2.5 concentrations were reduced further with a PM2.5 infiltration efficiency of 17%. A carefully selected air-conditioned public building could be used as a cleaner indoor air shelter during episodes of elevated smoke emissions. Further improvements in indoor air quality within the building can be achieved by operating appropriately sized HEPA cleaners.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Austrália , Monitoramento Ambiental , Humanos , Tamanho da Partícula , Material Particulado/análise , Fumaça/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...