Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 63(2): 377-382, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38227231

RESUMO

We demonstrate an all-fiber supercontinuum (SC) source delivering up to 40 W of average power ranging from 750 to 2200 nm. The laser source is based on a self-Q-switched pump-sharing oscillator-amplifier. The self-Q-switched master oscillator generates giant pulses, amplified in the high-power stage. Finally, a passive fiber acts as a nonlinear stage, improving the spectrum flatness as well as the spectral broadening. To the best of our knowledge, this is the first time that a pump-sharing oscillator-amplifier is used for SC generation and is based on the use of a submeter Ytterbium-doped fiber length inside the oscillator.

2.
ACS Photonics ; 10(11): 3915-3928, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38027249

RESUMO

Dispersive Fourier transform is a characterization technique that allows directly extracting an optical spectrum from a time domain signal, thus providing access to real-time characterization of the signal spectrum. However, these techniques suffer from sensitivity and dynamic range limitations, hampering their use for special applications in, e.g., high-contrast characterizations and sensing. Here, we report on a novel approach to dispersive Fourier transform-based characterization using single-photon detectors. In particular, we experimentally develop this approach by leveraging mutual information analysis for signal processing and hold a performance comparison with standard dispersive Fourier transform detection and statistical tools. We apply the comparison to the analysis of noise-driven nonlinear dynamics arising from well-known modulation instability processes. We demonstrate that with this dispersive Fourier transform approach, mutual information metrics allow for successfully gaining insight into the fluctuations associated with modulation instability-induced spectral broadening, providing qualitatively similar signatures compared to ultrafast photodetector-based dispersive Fourier transform but with improved signal quality and spectral resolution (down to 53 pm). The technique presents an intrinsically unlimited dynamic range and is extremely sensitive, with a sensitivity reaching below the femtowatt (typically 4 orders of magnitude better than ultrafast dispersive Fourier transform detection). We show that this method can not only be implemented to gain insight into noise-driven (spontaneous) frequency conversion processes but also be leveraged to characterize incoherent dynamics seeded by weak coherent optical fields.

3.
Sante Ment Que ; 48(1): 69-93, 2023.
Artigo em Francês | MEDLINE | ID: mdl-37862254

RESUMO

Background Remote psychosocial intervention has been used by most health care organizations since the beginning of COVID-19 pandemic. However, the rapid introduction of this type of practice generates new methods of intervention that raise many questions, particularly about men who, in general, use face-to-face psychosocial intervention less than women. This documentary research aims to report on current knowledge on remote psychosocial intervention with men. Methods PICO technique was used to find relevant documents to achieve the objective of this research. In accord with our criteria, 62 documents were selected in several databases and search engines. The selected texts were subject to an analysis process consisting of two stages: the creation of reading sheets followed by a content analysis. Results The results underline the lack of scientific data on the men's experience when they initiate a request for help, the commitment process, and the effectiveness of the remote intervention. Several elements seem potentially promising, including patients' perceptions of having more power and freedom which could favorize engagement of men who have a traditional vision of masculinity. Conclusions It appears that gender-related variables are not commonly used when it comes to analyze the effects of distance psychosocial intervention. Other studies will be needed to have a holistic vision of the realities experienced by men towards the offer of remote psychosocial intervention.


Assuntos
Pandemias , Intervenção Psicossocial , Masculino , Humanos , Feminino , Homens/psicologia , Masculinidade , Relações Interpessoais
4.
Opt Lett ; 48(11): 2905-2908, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37262240

RESUMO

Four-wave mixing is investigated when chirped pump and signal pulses are injected in a photonic crystal fiber. The shot-to-shot stability of the amplified coherent signal was measured by using the dispersive Fourier transform method and compared with numerical simulations. We highlight that the signal-to-noise ratio (SNR) of the pulsed signal increases with the injected power and show that it is not deteriorated through the amplification when the fiber optical parametric amplifier is strongly saturated. The SNR of the signal remains nearly constant after the amplifier.

5.
Int J Exerc Sci ; 16(4): 1385-1397, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38288069

RESUMO

The lack of specific on-ice tests to predict maximum lactate concentration limits the ability of coaches to better track and develop their ice hockey players. Thus, this study aimed to develop an equation for indirectly assessing the maximum lactate concentration produced from an all-out on-ice skating effort in elite adolescent ice hockey players. Twenty elite male ice hockey players participated in this study (age = 15.7 ± 1.0 year). The lactate anaerobic skating test (LAST) consisted of skating back and forth on an 18.2 m course at maximal speed with abrupt stops at each end for a total of 6 shuttles (total distance = 218.2 m; average time = 52.0 ± 2.0 s). The oxygen uptake was measured using a portable metabolic analyzer (Cosmed K4b2) and the maximum post-exercise lactate concentration with a Lactate Pro analyzer. The variables used to estimate lactate concentration were time, heart rate, number of skating strides in the last shuffle (6th) and the skating stride index. The average maximum lactate concentration was 14.4 mmol· L-1, which is expected in elite players. The analysis of explained common variance using T-test (r2 = 0.759) and linear regression (r2 = 0.863) demonstrates the validity of the model. Additionally, the root mean square error (RMSE = 0.60 mmol· L-1), the mean absolute error (MAE = 0.45mmol· L-1) and the standard error of estimate (SEE = 0.69 mmol· L-1) values further confirm the accuracy of the model. Thus, using simple and easy-to-measure variables (i.e., time and skating stride), coaches will be able to monitor more effectively their players' progress in an effort to optimize their individual on-ice performance.

6.
Opt Express ; 30(16): 29044-29062, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36299089

RESUMO

Temporally coherent supercontinuum sources constitute an attractive alternative to bulk crystal-based sources of few-cycle light pulses. We present a monolithic fiber-optic configuration for generating transform-limited temporally coherent supercontinuum pulses with central wavelength at 1.06 µm and duration as short as 13.0 fs (3.7 optical cycles). The supercontinuum is generated by the action of self-phase modulation and optical wave breaking when pumping an all-normal dispersion photonic crystal fiber with pulses of hundreds of fs duration produced by all-fiber chirped pulsed amplification. Avoidance of free-space propagation between stages confers unequalled robustness, efficiency and cost-effectiveness to this novel configuration. Collectively, the features of all-fiber few-cycle pulsed sources make them powerful tools for applications benefitting from the ultrabroadband spectra and ultrashort pulse durations. Here we exploit these features and the deep penetration of light in biological tissues at the spectral region of 1 µm, to demonstrate their successful performance in ultrabroadband multispectral and multimodal nonlinear microscopy.

7.
Opt Express ; 30(6): 8550-8559, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35299306

RESUMO

We report on the conception, fabrication and characterization of a new concept of optical fiber enabling a precise control of the ratio between the 2nd and 4th-order of chromatic dispersion (respectively ß2 and ß4) at 1.55 µm which is at the heart of the Four-Wave-Mixing (FWM) generation. For conventional highly nonlinear fiber the sensitivity of this ratio to fiber geometry fluctuations is very critical, making the fabrication process challenging. The new design fiber reconciles the accurate control of chromatic dispersion properties and fabrication by standard stack and draw method, allowing a robust and reliable method against detrimental fluctuations parameters during the fabrication process. Experimental frequency conversion with FWM in the new design fiber is demonstrated.

8.
Opt Lett ; 46(12): 2956-2959, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34129583

RESUMO

To prevent the thermally induced spatial beam degradation occurring in high-power fiber lasers and amplifiers, index-depressed core "fully aperiodic large-pitch fibers" (FA-LPFs) have been designed and fabricated. In contrast to previous experimental works performed on FA-LPFs, in which the active core and the surrounding cladding material are quasi-index-matched, the core refractive index is in slight depression compared to the surrounding material (Δn≈-3×10-5). Thus, the index-depressed fiber core tends first to behave as an anti-guide, preventing light from being properly guided into it. However, by increasing the absorbed pump power, the thermal load induces a parabolic refractive index change sufficient to compensate for the -3×10-5 index depression in the core, enabling a robust single-mode amplification at high average power. As a proof of concept, using a 110 µm depressed core FA-LPF, M2 values of 1.3 were demonstrated in amplifier configuration from 60 W to a maximal value of 170 W of emitted average power only limited by the available pump power.

9.
J Strength Cond Res ; 35(6): 1586-1592, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33555827

RESUMO

ABSTRACT: Ferland, P-M, Marcotte-L'Heureux, V, Roy, P, Carey, V, Charron, J, Lagrange, S, Leone, M, and Comtois, AS. Maximal oxygen consumption requirements in professional North American ice hockey. J Strength Cond Res 35(4): 1586-1592, 2021-This study was designed to measure preseason on-ice relative V̇o2max of professional ice-hockey players (n = 101 National Hockey League [NHL], 42 American Hockey League [AHL], 4 East Coast Hockey League [ECHL], and 15 Canadian Hockey League [CHL]) throughout 17 years and compare it between generations, league level, and position, and to verify if it was related to season and NHL career statistics. Relative V̇o2max was measured on ice with a portable metabolic analyzer (K4b2, Cosmed, Rome) with full hockey equipment, except for the helmet with either the Skating Multistage Aerobic Test or the 30-15 intermittent ice test tests. Relative V̇o2max results from both tests were compared between players of the same generation with an independent-samples T-test and were not significantly different. A one-way analysis of variance and post hoc pairwise tests were performed to detect significant differences between groups. Pearson correlations (two-tailed) were also performed between selected variables. All statistical significance was set at p < 0.05. Results show that there are no significant differences for relative V̇o2max between generations (2001-2003 vs. 2006 vs. 2015-2017), league level (NHL vs. AHL vs. ECHL vs. CHL), and position (winger, center, and defense), other than the ECHL being lower. There are also no significant relationships between V̇o2max values and hockey season and NHL career statistics. Thus, the results show that there is a minimal relative V̇o2max requirement to play North American ice hockey at the elite level (55.9 ± 5.2 ml·kg-1·min-1; n = 162). Future research should be directed toward comparing V̇o2max of elite and amateur ice-hockey players to confirm the minimal relative V̇o2max requirement to play North American ice hockey at the elite level.


Assuntos
Hóquei , Patinação , Canadá , Teste de Esforço , Humanos , Consumo de Oxigênio , Estados Unidos
10.
J Sports Med Phys Fitness ; 61(4): 551-561, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32734752

RESUMO

INTRODUCTION: The goal of this systematic and umbrella review was to regroup all systematic reviews, non-systematic reviews and all original articles into one convenient publication that would facilitate the theoretical and applied scientific investigations directed on cannabis consumption and exercise performance, to update current findings on the matters, and assess evidence quality. EVIDENCE ACQUISITION: The systematic review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) method. A computer-based systematic search was conducted in September 2019 through the Pubmed, Scopus and SPORTDiscus databases. The reliability of the systematic search was assured by having the article selection process entirely repeated by a second author. Strength of evidence of the selected articles was assesses using a modified version of the Downs and Black Checklist. EVIDENCE SYNTHESIS: The systematic search yielded a total of 8 peer-reviewed publications as well as 10 literature reviews. Results show that cannabis consumption prior to exercise induces decrements in performance (reduced ability to maintain effort, physical/maximal work capacity), undesired physiological responses (increased heart and breathing rate as well as myocardial oxygen demand) and neurological effects on balance (increased sway). CONCLUSIONS: Based on the articles included in this review, the authors conclude that cannabis consumption has an ergolytic effect on exercise performance and therefore does not act as a sport performance enhancing agent as raised by popular beliefs. Thus, cannabis consumption prior to exercise should be avoided in order to maximize performance in sports. Further research should mimic modern THC dosage (150 mg).


Assuntos
Desempenho Atlético/fisiologia , Canabinoides/farmacologia , Cannabis/efeitos adversos , Canabinoides/administração & dosagem , Humanos , Uso da Maconha/efeitos adversos , Reprodutibilidade dos Testes
11.
Int J Exerc Sci ; 13(4): 1190-1205, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33042370

RESUMO

The purpose of this study was to review acute physiological responses induced by repeated running sprint ability (RRSA) tests that could serve as references for practitioners utilising repeated sprints as a performance measure with athletes. This research was conducted following the PRISMA methodology. The systematic search was conducted in November 2019 and yielded 26 different scientific articles. Only peer-reviewed full-text article were included as abstracts are too short to allow proper explanation of the RRSAT methodology that was employed. According to the present literature, practitioners should use the following assessments: the 6×40m RRSA protocol with one Change of Direction (COD) (20+20 m with a 180° COD) and 25s of passive recovery between sprints with soccer players; the Intensive Repeated Sprint Ability (IRSA) test with men basketball players; the Futsal Intermittent Endurance Test (FIET) with futsal players; the Repeated Shuttle Sprint Test (RSST) with men handball players; and the Multiple Repeated Sprint Ability test for Badminton players (MRSAB). The present review should serve as a reference standard for RRSA tests. Further research should be directed towards creating and validating more specific RRSA tests protocols to each sports physiological and physical demands.

12.
Opt Lett ; 45(15): 4148-4151, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32735245

RESUMO

We report the spectral distribution of the parametric process generated in a photonic crystal fiber pumped by a chirped pulse. The spectral correlation of four-wave mixing has been measured using the dispersive Fourier transform method. From statistical analysis of multiple shot-to-shot spectral measurements, the spectral correlation between the signal and idler photons reveals physical insights into the particular portion of the pump spectrum responsible for generating the four-wave mixing. Therefore, the shape of the correlation map indicates directly the temporal and spectral links between the signal and the pump, which are highly important to design a four-wave mixing based amplifier.

13.
Opt Lett ; 44(19): 4690-4693, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31568418

RESUMO

We demonstrate a widely tunable Q-switched dual-wavelength fiber laser emitting synchronized pulses in the 2 µm spectral range. Owing to the use of a Tm-doped rod-type fully aperiodic large pitch fiber, together with an acousto-optic modulator and two volume Bragg gratings (VBGs), the wavelength separation was shown to be continuously tunable from 1 to 120 nm (∼0.1-10 THz). A peak power higher than 8 kW was demonstrated over the whole tuning range for a repetition rate (RR) of 1 KHz and a 26 ns pulse duration. The RR was modulated from 1 to 30 kHz, and the laser pulse duration measured between 23 ns and 130 ns, depending on the RR and the wavelength separation.

14.
Sci Rep ; 9(1): 13711, 2019 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-31548555

RESUMO

Cumulative CO2 emissions are a robust predictor of mean temperature increase. However, many societal impacts are driven by exposure to extreme weather conditions. Here, we show that cumulative emissions can be robustly linked to regional changes of a heat exposure indicator, as well as the resulting socioeconomic impacts associated with labour productivity loss in vulnerable economic sectors. We estimate historical and future increases in heat exposure using simulations from eight Earth System Models. Both the global intensity and spatial pattern of heat exposure evolve linearly with cumulative emissions across scenarios (1% CO2, RCP4.5 and RCP8.5). The pattern of heat exposure at a given level of global temperature increase is strongly affected by non-CO2 forcing. Global non-CO2 greenhouse gas emissions amplify heat exposure, while high local emissions of aerosols could moderate exposure. Considering CO2 forcing only, we commit ourselves to an additional annual loss of labour productivity of about 2% of total GDP per unit of trillion tonne of carbon emitted. This loss doubles when adding non-CO2 forcing of the RCP8.5 scenario. This represents an additional economic loss of about 4,400 G$ every year (i.e. 0.59 $/tCO2), varying across countries with generally higher impact in lower-income countries.

15.
Appl Opt ; 57(29): 8582-8585, 2018 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-30461927

RESUMO

Based on a special large-pitch architecture that has already proved its single-mode single-polarization behavior in a passive configuration, two ytterbium-doped versions of such large-mode-area fibers have been fabricated and tested in both laser and amplification configurations for high-power laser source applications. Due to the high sensitivity of large-pitch fiber design to the active-core-to-passive-cladding index mismatch, the realization of a single-polarization structure is highly challenging. However, we report on the preservation of a polarization-maintaining feature. A linear polarization with an extinction ratio of 17 dB is demonstrated for mode field diameters reaching up to 58 µm as long as the single-modeness of the emitted signal is preserved.

16.
Sensors (Basel) ; 18(8)2018 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-30072611

RESUMO

In this paper, different core structures of microstructured optical fibers (MOFs) for low-finesse Fabry⁻Pérot (FP) sensors are experimentally compared to get the highest sensitivity. These devices are designed for volatile organic compounds (VOCs) measurements. Indium tin oxide (ITO) thin films were deposited by sputtering on the MOFs and different optical fast Fourier transform (FFT) phase responses from the FP were measured for saturated atmospheres of ethanol. It has been demonstrated that the sensitivities of the developed sensors depend strongly on the geometry and the dimensions of the MOF-cores. The sensors show recovery times shorter than 100 s and the baselines are fully recovered after every exposure to ethanol vapors.

17.
Opt Express ; 26(9): 11265-11275, 2018 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-29716050

RESUMO

We present a detailed study on the generation of widely tunable visible light through four wave mixing in specifically designed micro-structured fibers. The fiber's properties are optimized for an efficient conversion to the visible and near infrared with a combined tunability from 620 to 910 nm of a picosecond Yb-doped tunable source for biomedical applications.

18.
Crisis ; 39(2): 137-143, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28914093

RESUMO

BACKGROUND: The Province of Quebec, Canada (PQ), witnessed a drastic rise in suicide among adult men between 1990 and 2000, followed by a continuous drop since then. At the end of the 1990s, men's suicide became recognized as a social issue, leading to implementation of gender-responsive strategies focusing on positive aspects of masculinity. Many of these strategies received positive assessments. AIMS: This article offers a critical overview of the evolution of social responses to men's suicide in PQ. METHOD: We highlight elements of success with examples of interventions targeting men directly, professionals who work with men, and natural support networks of men. RESULTS: Results and discussion suggest the benefits to shift towards salutogenic, gender-transformative approach to men's suicide prevention. CONCLUSION: Closing remarks question the current gaps and upcoming challenges in suicide prevention among men.


Assuntos
Política de Saúde , Saúde do Homem , Saúde Mental , Serviço Social , Prevenção do Suicídio , Promoção da Saúde , Humanos , Masculino , Masculinidade , Homens , Quebeque
19.
Sensors (Basel) ; 17(12)2017 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-29189755

RESUMO

In this work, the performance of five different fiber optic sensors at cryogenic temperatures has been analyzed. A photonic crystal fiber Fabry-Pérot interferometer, two Sagnac interferometers, a commercial fiber Bragg grating (FBG), and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser have been studied. Their sensitivities and resolutions as sensors for cryogenic temperatures have been compared regarding their advantages and disadvantages. Additionally, the results have been compared with the given by a commercial optical backscatter reflectometer that allowed for distributed temperature measurements of a single mode fiber.

20.
Opt Lett ; 42(24): 5230-5233, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-29240180

RESUMO

We report here on an experimental investigation of the temporal behavior of transverse mode instabilities into "fully aperiodic large-pitch fibers" (FA-LPFs) operated in high-power continuous-wave laser configuration. To ensure an effective transverse single-mode emission into FA-LPFs, a perfect index matching between the active core and the background cladding materials (Δn=0) is required. The original design of such fibers enables an effective transverse single-mode emission by strengthening the higher-order mode delocalization out of the gain region, even for high heat load levels, consequently leading to the improvement of the beam spatial quality. The study was conducted over fibers of various gain region diameters, from 58 to 100 µm, for a refractive index mismatch Δn of about +8×10-5. The emitted beam is characterized using both M2 measurements and time traces to study the changeover of a stable temporal behavior to an unstable one.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...