Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38741699

RESUMO

The stiffness of the extracellular matrix induces differential tension within integrin-based adhesions, triggering differential mechanoresponses. However, it has been unclear if the stiffness-dependent differential tension is induced solely by myosin activity. Here, we report that in the absence of myosin contractility, 3T3 fibroblasts still transmit stiffness-dependent differential levels of traction. This myosin-independent differential traction is regulated by polymerizing actin assisted by actin nucleators Arp2/3 and formin where formin has a stronger contribution than Arp2/3 to both traction and actin flow. Intriguingly, despite only slight changes in F-actin flow speed observed in cells with the combined inhibition of Arp2/3 and myosin compared to cells with sole myosin inhibition, they show a 4-times reduction in traction than cells with myosin-only inhibition. Our analyses indicate that traditional models based on rigid F-actin are inadequate for capturing such dramatic force reduction with similar actin flow. Instead, incorporating the F-actin network's viscoelastic properties is crucial. Our new model including the F-actin viscoelasticity reveals that Arp2/3 and formin enhance stiffness sensitivity by mechanically reinforcing the F-actin network, thereby facilitating more effective transmission of flow-induced forces. This model is validated by cell stiffness measurement with atomic force microscopy and experimental observation of model-predicted stiffness-dependent actin flow fluctuation.

2.
Am J Physiol Heart Circ Physiol ; 326(5): H1180-H1192, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38457352

RESUMO

Endothelial cells (ECs) within the vascular system encounter fluid shear stress (FSS). High, laminar FSS promotes vasodilation and anti-inflammatory responses, whereas low or disturbed FSS induces dysfunction and inflammation. However, the adaptation of endothelial cells (ECs) to dynamically changing FSS patterns remains underexplored. Here, by combining traction force microscopy with a custom flow chamber, we examined human umbilical vein endothelial cells adapting their traction during transitions from short-term low shear to long-term high shear stress. We discovered that the initial low FSS elevates the traction by only half of the amount in response to direct high FSS even after flow changes to high FSS. However, in the long term under high FSS, the flow started with low FSS triggers a substantial second rise in traction for over 10 h. In contrast, the flow started directly with high FSS results in a quick traction surge followed by a huge reduction below the baseline traction in <30 min. Importantly, we find that the orientation of traction vectors is steered by initial shear exposure. Using Granger causality analysis, we show that the traction that aligns in the flow direction under direct high FSS functionally causes cell alignment toward the flow direction. However, EC traction that orients perpendicular to the flow that starts with temporary low FSS functionally causes cell orientation perpendicular to the flow. Taken together, our findings elucidate the significant influence of initial short-term low FSS on lasting changes in endothelial traction that induces EC alignment.NEW & NOTEWORTHY In our study, we uncover that preconditioning with low shear stress yields enduring impacts on endothelial cell traction and orientation, persisting even after transitioning to high-shear conditions. Using Granger causality analysis, we demonstrate a functional link between the direction of cell traction and subsequent cellular alignment across varying shear environments.


Assuntos
Células Endoteliais da Veia Umbilical Humana , Estresse Mecânico , Humanos , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células Cultivadas , Mecanotransdução Celular , Fatores de Tempo , Adesão Celular
3.
bioRxiv ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37790318

RESUMO

Within the vascular system, endothelial cells (ECs) are exposed to fluid shear stress (FSS), a mechanical force exerted by blood flow that is critical for regulating cellular tension and maintaining vascular homeostasis. The way ECs react to FSS varies significantly; while high, laminar FSS supports vasodilation and suppresses inflammation, low or disturbed FSS can lead to endothelial dysfunction and increase the risk of cardiovascular diseases. Yet, the adaptation of ECs to dynamically varying FSS remains poorly understood. This study focuses on the dynamic responses of ECs to brief periods of low FSS, examining its impact on endothelial traction-a measure of cellular tension that plays a crucial role in how endothelial cells respond to mechanical stimuli. By integrating traction force microscopy (TFM) with a custom-built flow chamber, we analyzed how human umbilical vein endothelial cells (HUVECs) adjust their traction in response to shifts from low to high shear stress. We discovered that initial exposure to low FSS prompts a marked increase in traction force, which continues to rise over 10 hours before slowly decreasing. In contrast, immediate exposure to high FSS causes a quick spike in traction followed by a swift reduction, revealing distinct patterns of traction behavior under different shear conditions. Importantly, the direction of traction forces and the resulting cellular alignment under these conditions indicate that the initial shear experience dictates long-term endothelial behavior. Our findings shed light on the critical influence of short-lived low-shear stress experiences in shaping endothelial function, indicating that early exposure to low FSS results in enduring changes in endothelial contractility and alignment, with significant consequences for vascular health and the development of cardiovascular diseases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...