Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Perinatol ; 44(6): 865-872, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38548866

RESUMO

OBJECTIVE: To evaluate the association and utility of low 1- and 5-min Apgar scores to identify short-term morbidities in a large newborn cohort. METHODS: 15,542 infants >22 weeks gestation from a single center were included. Clinical data and low Apgar scores were analyzed for significance to ten short-term outcomes and were used to construct Receiver Operating Characteristic Curves and the AUC calculated for ten outcomes. RESULTS: A low Apgar score related to all (1-min) or most (5-min) outcomes by univariate and multivariate logistic regression analysis. Including any of the 4 low Apgar scores only improved the clinical factor AUC by 0.9% ± 2.7% (±SD) and was significant in just 5 of the 40 score/outcome scenarios. CONCLUSION: The contribution of a low Apgar score for identifying risk of short-term morbidity does not appear to be clinically significant.


Assuntos
Índice de Apgar , Humanos , Recém-Nascido , Feminino , Masculino , Curva ROC , Estudos de Coortes , Modelos Logísticos , Estudos Retrospectivos , Recém-Nascido Prematuro , Idade Gestacional
4.
Neonatology ; 120(3): 363-370, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36996764

RESUMO

INTRODUCTION: Current oxygen monitoring by pulse oximetry has limitations and cannot provide estimates of the oxygen content in the microvasculature, where oxygen is used. Resonance Raman spectroscopy (RRS) provides noninvasive microvascular oxygen measurement. The objectives of this study were to (i) measure the correlation between preductal RRS microvascular oxygen saturations (RRS-StO2) and central venous oxygen saturation (SCVO2), (ii) develop normative data for RRS-StO2 measurements in healthy preterm infants, and (iii) determine the effect of blood transfusion on RRS-StO2. METHODS: Thirty-three buccal and thenar RRS-StO2 measurements were performed in 26 subjects to correlate RRS-StO2 with SCVO2. Thirty-one measurements were performed in 28 subjects to develop normative RRS-StO2 values, and eight subjects were enrolled in the transfusion group to assess changes in RRS-StO2 with blood transfusion. RESULTS: There were good correlations for buccal (r = 0.692) and thenar (r = 0.768) RRS-StO2 versus SCVO2. The median RRS-StO2 in healthy subjects was 76% (IQR 68.7-80.8). There was a significant increase of 7.8 ± 4.6% in the thenar RRS-StO2 after blood transfusion. CONCLUSIONS: RRS appears to be a safe and noninvasive means of monitoring microvascular oxygenation. Thenar RRS-StO2 measurements are more feasible and practical to use than buccal. In healthy preterm infants, the median RRS-StO2 was calculated based on measurements across various gestational age and gender. More studies evaluating the effects of gestational age of RRS-StO2 in various critical clinical settings are needed to confirm the findings.


Assuntos
Recém-Nascido Prematuro , Análise Espectral Raman , Lactente , Humanos , Recém-Nascido , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Consumo de Oxigênio , Oximetria , Oxigênio
5.
J Perinat Med ; 51(4): 580-585, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-36410713

RESUMO

OBJECTIVES: To review how the Apgar score is used in published clinical research as well as who uses it, and how this may have changed between 1989-90 and 2018-19. METHODS: Pubmed search for English publications using MeSH Terms "apgar score" OR "apgar" AND "score" AND "humans" for epochs 1989-90 & 2018-19. The location and specialty of first author, primary purpose and how the Apgar score was used was recorded. RESULTS: There was a 61% increase in number of publications in 2018-19 compared to 1989-90, from all regions except North America. The most common purpose for using the Apgar was to assess newborn status after pregnancy/delivery interventions. There were 50 different definitions of a significant score. Definition of significance was influenced by specialty in 2018-19 and by study purpose in both epochs. CONCLUSIONS: Most studies using the Apgar score are focused on the mother. There is no consistent definition of a significant score. Development of any future newborn assessment tools should account for the multiple purposes for which the Apgar score is used.


Assuntos
Índice de Apgar , Recém-Nascido , Gravidez , Feminino , Humanos
7.
Paediatr Respir Rev ; 43: 38-43, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34933823

RESUMO

The provision of exogenous surfactant to premature infants with respiratory distress syndrome has revolutionized the way we care for these patients, significantly improving survival and decreasing morbidity. Currently, the Intubate-SURfactant-Extubate (INSURE) to non-invasive ventilation method remains the standard method for surfactant delivery in the United States. However, the INSURE method requires intubation via direct visualization with a laryngoscope and possible need for sedation. Both carry significant risk to the patients, prompting the development of less invasive ways of safely and efficaciously providing surfactant to newborn infants. The present article reviews and describes the benefits and limitations of several of these alternative methods, including Less Invasive Surfactant Administration (LISA), Minimally Invasive Surfactant Therapy (MIST), via aerosolization, laryngeal mask airway (LMA), and direct nasopharyngeal deposition, focusing on assessment of clinical benefits and the level/risk of invasiveness.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Recém-Nascido , Humanos , Tensoativos/uso terapêutico , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/etiologia , Recém-Nascido Prematuro , Respiração Artificial/métodos
8.
Pediatr Res ; 2021 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-34969993

RESUMO

Assessment of an infant's condition in the delivery room represents a prerequisite to adequately initiate medical support. In her seminal paper, Virginia Apgar described five parameters to be used for such an assessment. However, since that time maternal and neonatal care has changed; interventions were improved and infants are even more premature. Nevertheless, the Apgar score is assigned to infants worldwide but there are concerns about low interobserver reliability, especially in preterm infants. Also, resuscitative interventions may preclude the interpretation of the score, which is of concern when used as an outcome parameter in delivery room intervention studies. Within the context of these changes, we performed a critical appraisal on how to assess postnatal condition of the newborn including the clinical parameters of the Apgar score, as well as selected additional parameters and a proposed new scoring system. The development of a new scoring system that guide clinicians in assessing infants and help to decide how to support postnatal adaptation is discussed. IMPACT: This critical paper discusses the reliability of the Apgar score, as well as additional parameters, in order to improve assessment of a newborn's postnatal condition. A revised neonatal scoring system should account for infant maturity and the interventions administered. Delivery room assessment should be directed toward determining how much medical support is needed and how the infant responds to these interventions.

9.
JAMA Pediatr ; 175(2): 207, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32926080
10.
Paediatr Respir Rev ; 35: 31-37, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32709462

RESUMO

Beginning in late 2019, a novel coronavirus labeled SARS-CoV-2 spread around the world, affecting millions. The impact of the disease on patients and on health care delivery has been unprecedented. Here, we review what is currently known about the effects of the virus and its clinical condition, Covid-19 in areas of relevance to those providing care to neonates. While aspects of pregnancy, including higher expression of the cell receptor for the virus, ACE2, could put these women at higher risk, preliminary epidemiological information does not support this. Viral carriage prevalence based on universal screening show that rates vary from 13% in "hot spots" such as New York City, to 3% in areas with lower cases. Vertical transmission risks are unknown but 3.1% of 311 babies born to mothers with Covid-19 were positive within a week of birth. The clinical description of 26 neonates <30 days of age showed no deaths and only one requiring intensive care. Risks for breast-feeding and for milk banks are discussed.


Assuntos
Aleitamento Materno , Infecções por Coronavirus/epidemiologia , Leite Humano/virologia , Pneumonia Viral/epidemiologia , Complicações Infecciosas na Gravidez/epidemiologia , Aborto Induzido , Aborto Espontâneo/epidemiologia , Betacoronavirus , COVID-19 , Infecções por Coronavirus/fisiopatologia , Infecções por Coronavirus/terapia , Infecções por Coronavirus/transmissão , Feminino , Humanos , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas , Bancos de Leite Humano , Pandemias , Pneumonia Viral/fisiopatologia , Pneumonia Viral/terapia , Pneumonia Viral/transmissão , Gravidez , Complicações Infecciosas na Gravidez/fisiopatologia , Complicações Infecciosas na Gravidez/terapia , SARS-CoV-2
11.
JAMA Pediatr ; 174(4): 321-322, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32091567
12.
Pediatr Pulmonol ; 54(11): 1742-1746, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31373180

RESUMO

Neurally adjusted ventilatory assistance (NAVA) can overcome technical difficulties with synchronizing noninvasive ventilation breaths with the patient, a modality often used in very low birthweight infants (VLBW) with apnea of prematurity (AOP). This study is a retrospective single-center investigation into whether NAVA-synchronized noninvasive (niNAVA) ventilation is better than nonsynchronized (nasal intermittent positive pressure ventilation [nIPPV]) for symptomatic apnea in VLBW infants. Nursing records of apnea, bradycardia, and/or desaturations were abstracted from the electronic medical records of 108 VLBW infants admitted to the neonatal intensive care unit (NICU) from 2015 to 2017 who received either of the two modalities, 61 epochs of niNAVA totaling 488 days and 103 epochs of nIPPV totaling 886.5 days. niNAVA was associated with a significant reduction in the number of isolated bradycardic events/day (0.48 ± 0.14 vs 1.35 ± 0.27; P = .019) and overall bradycardias/day (2.42 ± 0.47 vs 4.02 ± 0.53; P = .042) and there were more epochs with no events with niNAVA compared with nIPPV (23.0% vs 6.8%; P = .004). These results justify a prospective trial of NAVA-synchronized noninvasive ventilation for VLBW infants with caffeine-resistant AOP.


Assuntos
Apneia/terapia , Bradicardia/terapia , Suporte Ventilatório Interativo , Ventilação com Pressão Positiva Intermitente , Ventilação não Invasiva , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal , Masculino , Estudos Retrospectivos
13.
J Perinatol ; 38(11): 1594, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30232376

RESUMO

Since the publication of the above article, the authors have noted that the name of the first Item in the NRAS scoring system in Figure 1 was omitted. It is Heart Rate (C1). The authors apologise for any inconvenience caused by this error. The html and online pdf versions have now been rectified and carry the corrected Figure.

14.
J Perinatol ; 38(11): 1476-1482, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30093618

RESUMO

OBJECTIVE: To test the non-inferiority of an alternative to the Apgar score. STUDY DESIGN: The Neonatal Resuscitation and Adaptation Score (NRAS) was recorded in parallel to the Apgar score by a resuscitation team at deliveries. Correlation between the systems was assessed, as well as the predictive ability of NRAS and Apgar scores for mortality or short-term morbidities. RESULTS: A total of 340 infants were in the study group. The two scores correlated strongly (r = 0.87 and 0.83 at 1 and 5 min, respectively). Those needing ventilation at 48 h of life had a 5-min NRAS < 7 in 23/26 vs Apgar < 7 (23/36, p = 0.001). A low (0-3) 1-min NRAS score was more predictive of death, 53% vs 17%, p = 0.0065. CONCLUSIONS: NRAS correlates with Apgar status assessment, and identifies newborns who die or may require further care better than the Apgar score.


Assuntos
Índice de Apgar , Medição de Risco/métodos , Asfixia Neonatal/terapia , Peso ao Nascer , Idade Gestacional , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido , Modelos Lineares , Ressuscitação , Fatores de Risco
15.
PLoS One ; 13(6): e0198425, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29902195

RESUMO

Non-invasive ventilation is increasingly used for respiratory support in preterm infants, and is associated with a lower risk of chronic lung disease. However, this mode is often not successful in the extremely preterm infant in part due to their markedly increased chest wall compliance that does not provide enough structure against which the forces of inhalation can generate sufficient pressure. To address the continued challenge of studying treatments in this fragile population, we developed a nonlinear lumped-parameter respiratory system mechanics model of the extremely preterm infant that incorporates nonlinear lung and chest wall compliances and lung volume parameters tuned to this population. In particular we developed a novel empirical representation of progressive volume loss based on compensatory alveolar pressure increase resulting from collapsed alveoli. The model demonstrates increased rate of volume loss related to high chest wall compliance, and simulates laryngeal braking for elevation of end-expiratory lung volume and constant positive airway pressure (CPAP). The model predicts that low chest wall compliance (chest stiffening) in addition to laryngeal braking and CPAP enhance breathing and delay lung volume loss. These results motivate future data collection strategies and investigation into treatments for chest wall stiffening.


Assuntos
Lactente Extremamente Prematuro , Pulmão/fisiologia , Mecânica Respiratória , Humanos , Recém-Nascido , Complacência Pulmonar , Modelos Teóricos
17.
Am J Perinatol ; 34(9): 911-917, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28320035

RESUMO

Background Soluble receptor for advanced glycation end-products (sRAGE), a soluble isoform of the RAGE receptor, is elevated in lungs from patients with acute conditions such as acute respiratory distress syndrome and bronchiolitis. This study investigated whether sRAGE is present in ventilated infants. Methods Tracheal aspirates from the first week or the fifth week of life were obtained from intubated very low birth weight subjects and analyzed by Western blot. Immunohistochemistry analysis for sRAGE was performed on paraffin-embedded lung autopsy slides from 19 other infants. Results The sRAGE band densities were similar among the seven infants who fully recovered, eight who developed bronchopulmonary dysplasia (BPD), and 5 who died (analysis of variance p = 0.797) but was higher at 4 weeks, p = 0.0324. There was minimal sRAGE staining in the autopsied lungs from previable infants (20-21 weeks) or from those who were not ventilated or had mild lung disease. In contrast, substantial staining was present in two of three with BPD, and those who received high ventilatory support. Conclusion sRAGE is present in ventilated infants. Levels are generally higher in those who receive prolonged or vigorous mechanical ventilation. Since sRAGE may have roles in inflammation and cell adherence, its role in the development of BPD may warrant study.


Assuntos
Displasia Broncopulmonar/patologia , Receptor para Produtos Finais de Glicação Avançada/metabolismo , Autopsia , Displasia Broncopulmonar/terapia , Feminino , Humanos , Imuno-Histoquímica , Lactente Extremamente Prematuro , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Pulmão/metabolismo , Pulmão/patologia , Masculino , Receptor para Produtos Finais de Glicação Avançada/análise , Respiração Artificial , Virginia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...