1.
Neuroimage ; 221: 117157, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32659354

RESUMO

Magnetoencephalography (MEG) has a unique capacity to resolve the spatio-temporal development of brain activity from non-invasive measurements. Conventional MEG, however, relies on sensors that sample from a distance (20-40 â€‹mm) to the head due to thermal insulation requirements (the MEG sensors function at 4 â€‹K in a helmet). A gain in signal strength and spatial resolution may be achieved if sensors are moved closer to the head. Here, we report a study comparing measurements from a seven-channel on-scalp SQUID MEG system to those from a conventional (in-helmet) SQUID MEG system. We compared the spatio-temporal resolution between on-scalp and conventional MEG by comparing the discrimination accuracy for neural activity patterns resulting from stimulating five different phalanges of the right hand. Because of proximity and sensor density differences between on-scalp and conventional MEG, we hypothesized that on-scalp MEG would allow for a more high-resolved assessment of these activity patterns, and therefore also a better classification performance in discriminating between neural activations from the different phalanges. We observed that on-scalp MEG provided better classification performance during an early post-stimulus period (10-20 â€‹ms). This corresponded to the electroencephalographic (EEG) component P16/N16 and was an unexpected observation as this component is usually not observed in conventional MEG. This finding shows that on-scalp MEG enables a richer registration of the cortical signal, indicating a sensitivity to what are potentially sources in the thalamo-cortical radiation. We had originally expected that on-scalp MEG would provide better classification accuracy based on activity in proximity to the P60m component compared to conventional MEG. This component indeed allowed for the best classification performance for both MEG systems (60-75%, chance 50%). However, we did not find that on-scalp MEG allowed for better classification than conventional MEG at this latency. We suggest that this absence of differences is due to the limited sensor coverage in the recording, in combination with our strategy for positioning the on-scalp MEG sensors. We show how the current sensor coverage may have limited our chances to register the necessary between-phalange source field dissimilarities for fair hypothesis testing, an approach we otherwise believe to be useful for future benchmarking measurements.


Assuntos
Córtex Cerebral/fisiologia , Eletroencefalografia/métodos , Potenciais Somatossensoriais Evocados/fisiologia , Dedos/fisiologia , Magnetoencefalografia/métodos , Magnetoencefalografia/normas , Percepção do Tato/fisiologia , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
2.
Clin Neurophysiol ; 131(8): 1711-1720, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32504930

RESUMO

OBJECTIVE: Conventional MEG provides an unsurpassed ability to, non-invasively, detect epileptic activity. However, highly resolved information on small neuronal populations required in epilepsy diagnostics is lost and can be detected only intracranially. Next-generation on-scalp magnetencephalography (MEG) sensors aim to retrieve information unavailable to conventional non-invasive brain imaging techniques. To evaluate the benefits of on-scalp MEG in epilepsy, we performed the first-ever such measurement on an epilepsy patient. METHODS: Conducted as a benchmarking study focusing on interictal epileptiform discharge (IED) detectability, an on-scalp high-temperature superconducting quantum interference device magnetometer (high-Tc SQUID) system was compared to a conventional, low-temperature SQUID system. Co-registration of electroencephalopraphy (EEG) was performed. A novel machine learning-based IED-detection algorithm was developed to aid identification of on-scalp MEG unique IEDs. RESULTS: Conventional MEG contained 24 IEDs. On-scalp MEG revealed 47 IEDs (16 co-registered by EEG, 31 unique to the on-scalp MEG recording). CONCLUSION: Our results indicate that on-scalp MEG might capture IEDs not seen by other non-invasive modalities. SIGNIFICANCE: On-scalp MEG has the potential of improving non-invasive epilepsy evaluation.


Assuntos
Ondas Encefálicas/fisiologia , Encéfalo/fisiopatologia , Epilepsia/fisiopatologia , Magnetoencefalografia/métodos , Convulsões/fisiopatologia , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Feminino , Humanos , Magnetoencefalografia/instrumentação , Pessoa de Meia-Idade , Couro Cabeludo/fisiopatologia
3.
Neuroimage ; 212: 116686, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-32119981

RESUMO

Source modelling in magnetoencephalography (MEG) requires precise co-registration of the sensor array and the anatomical structure of the measured individual's head. In conventional MEG, the positions and orientations of the sensors relative to each other are fixed and known beforehand, requiring only localization of the head relative to the sensor array. Since the sensors in on-scalp MEG are positioned on the scalp, locations of the individual sensors depend on the subject's head shape and size. The positions and orientations of on-scalp sensors must therefore be measured at every recording. This can be achieved by inverting conventional head localization, localizing the sensors relative to the head - rather than the other way around. In this study we present a practical method for localizing sensors using magnetic dipole-like coils attached to the subject's head. We implement and evaluate the method in a set of on-scalp MEG recordings using a 7-channel on-scalp MEG system based on high critical temperature superconducting quantum interference devices (high-Tc SQUIDs). The method allows individually localizing the sensor positions, orientations, and responsivities with high accuracy using only a short averaging time (≤ 2 â€‹mm, < 3° and < 3%, respectively, with 1-s averaging), enabling continuous sensor localization. Calibrating and jointly localizing the sensor array can further improve the accuracy of position and orientation (< 1 â€‹mm and < 1°, respectively, with 1-s coil recordings). We demonstrate source localization of on-scalp recorded somatosensory evoked activity based on co-registration with our method. Equivalent current dipole fits of the evoked responses corresponded well (within 4.2 â€‹mm) with those based on a commercial, whole-head MEG system.


Assuntos
Mapeamento Encefálico/instrumentação , Mapeamento Encefálico/métodos , Magnetoencefalografia/instrumentação , Magnetoencefalografia/métodos , Couro Cabeludo , Adulto , Encéfalo/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
IEEE Trans Biomed Eng ; 67(5): 1483-1489, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31484107

RESUMO

OBJECTIVE: To present the technical design and demonstrate the feasibility of a multi-channel on-scalp magnetoencephalography (MEG) system based on high critical temperature (high-[Formula: see text]) superconducting quantum interference devices (SQUIDs). METHODS: We built a liquid nitrogen-cooled cryostat that houses seven YBCO SQUID magnetometers arranged in a dense, head-aligned array with minimal distance to the room-temperature environment for all sensors. We characterize the performance of this 7-channel system in terms of on-scalp MEG utilization and present recordings of spontaneous and evoked brain activity. RESULTS: The center-to-center spacing between adjacent SQUIDs is 12.0 and 13.4 mm and all SQUIDs are in the range of 1-3 mm of the head surface. The cryostat reaches a base temperature of  âˆ¼ 70 K and stays cold for 16 h with a single 0.9 L filling. The white noise levels of the magnetometers is 50-130 fT/Hz1/2 at 10 Hz and they show low sensor-to-sensor feedback flux crosstalk ( 0.6%). We demonstrate evoked fields from auditory stimuli and single-shot sensitivity to alpha modulation from the visual cortex. CONCLUSION: All seven channels in the system sensitively sample neuromagnetic fields with mm-scale scalp standoff distances. The hold time of the cryostat furthermore is sufficient for a day of recordings. As such, our multi-channel high-[Formula: see text] SQUID-based system meets the demands of on-scalp MEG. SIGNIFICANCE: The system presented here marks the first high-[Formula: see text] SQUID-based on-scalp MEG system with more than two channels. It enables us to further explore the benefits of on-scalp MEG in future recordings.


Assuntos
Magnetoencefalografia , Couro Cabeludo , Animais , Encéfalo , Decapodiformes
5.
PLoS One ; 12(7): e0178602, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28742118

RESUMO

The development of new magnetic sensor technologies that promise sensitivities approaching that of conventional MEG technology while operating at far lower operating temperatures has catalysed the growing field of on-scalp MEG. The feasibility of on-scalp MEG has been demonstrated via benchmarking of new sensor technologies performing neuromagnetic recordings in close proximity to the head surface against state-of-the-art in-helmet MEG sensor technology. However, earlier work has provided little information about how these two approaches compare, or about the reliability of observed differences. Herein, we present such a comparison, based on recordings of the N20m component of the somatosensory evoked field as elicited by electric median nerve stimulation. As expected from the proximity differences between the on-scalp and in-helmet sensors, the magnitude of the N20m activation as recorded with the on-scalp sensor was higher than that of the in-helmet sensors. The dipole pattern of the on-scalp recordings was also more spatially confined than that of the conventional recordings. Our results furthermore revealed unexpected temporal differences in the peak of the N20m component. An analysis protocol was therefore developed for assessing the reliability of this observed difference. We used this protocol to examine our findings in terms of differences in sensor sensitivity between the two types of MEG recordings. The measurements and subsequent analysis raised attention to the fact that great care has to be taken in measuring the field close to the zero-line crossing of the dipolar field, since it is heavily dependent on the orientation of sensors. Taken together, our findings provide reliable evidence that on-scalp and in-helmet sensors measure neural sources in mostly similar ways.


Assuntos
Magnetoencefalografia/métodos , Encéfalo/fisiologia , Estimulação Elétrica , Potenciais Somatossensoriais Evocados/fisiologia , Habituação Psicofisiológica , Dispositivos de Proteção da Cabeça , Humanos , Magnetoencefalografia/instrumentação , Magnetoencefalografia/estatística & dados numéricos , Nervo Mediano/fisiologia , Modelos Neurológicos , Reprodutibilidade dos Testes , Couro Cabeludo
SELEÇÃO DE REFERÊNCIAS