Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Radiat Oncol ; 8(3): 101151, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36691448

RESUMO

Purpose: Stereotactic radiosurgery (SRS) immobilization with an open face mask is more comfortable and less invasive than frame based, but concerns about intrafraction motion must be addressed. Surface-guided radiation therapy (SGRT) is an attractive option for intrafraction patient monitoring because it is continuous, has submillimeter accuracy, and uses no ionizing radiation. The purpose of this study was to investigate the dosimetric consequences of uncorrected intrafraction patient motion detected during frameless linac-based SRS. Methods and Materials: Fifty-five SRS patients were monitored during treatment using SGRT between January 1, 2017, and September 30, 2020. If SGRT detected motion >1 mm, imaging was repeated and the necessary shifts were made before continuing treatment. For the 25 patients with intrafraction 3-dimensional vector shifts of ≥1 mm, we moved the isocenter in the planning system using the translational shifts from the repeat imaging and recalculated the plans to determine the dosimetric effect of the shifts. Planning target volume (PTV) coverage, minimum gross tumor volume (GTV) dose (relative and absolute), and normal brain V12 were evaluated. Wilcoxon signed rank tests were used to compare planned and simulated dosimetric parameters and median 2 sample tests were used to investigate these differences between cone and multileaf collimator (MLC) plans. Results: For simulated plans, V12 increased by a median of 0.01 cc (P = .006) and relative GTV minimum dose and PTV coverage decreased by a median of 15.8% (P < .001) and 10.2 % (P < .001), respectively. Absolute minimum GTV dose was found to be significantly lower in the simulated plans (P < .001). PTV coverage decreased more for simulated cone plans than for simulated MLC plans (11.6% vs 4.7%, P = .011) but median V12 differences were found to be significantly larger for MLC plans (-0.34 cc vs -0.01 cc, P = .011). Differences in GTV minimum dose between cone and MLC plans were not statistically significant. Conclusions: SGRT detected clinically meaningful intrafraction motion during frameless SRS, which could lead to large underdoses and increased normal brain dose if uncorrected.

2.
J Appl Clin Med Phys ; 23(4): e13541, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35112445

RESUMO

Despite breast cancer prevalence and widespread adoption of deep inspiration breath-hold (DIBH) radiation techniques, few data exist on the error risks related to using surface-guided (SG) DIBH during breast radiation therapy (RT). Due to the increasingly technical nature of these methods and being a paradigm shift from traditional breast setups/treatments, the associated risk for error is high. Failure modes and effects analysis (FMEA) has been used in identifying risky RT processes yet is time-consuming to perform. A subset of RT staff and a hospital patient-safety representative performed FMEA to study SG-DIBH RT processes. After this group (cohort 1) analyzed these processes, additional scoring data were acquired from RT staff uninvolved in the original FMEA (cohort 2). Cohort 2 received abbreviated FMEA training while using the same process maps that cohort 1 had created, which was done with the goal of validating our results and exploring the feasibility of expedited FMEA training and efficient implementation elsewhere. An extensive review of the SG-DIBH RT process revealed 57 failure modes in 16 distinct steps. Risks deemed to have the highest priority, large risk priority number (RPN), and severity were addressed with policy changes, checklists, and standardization; of these, most were linked with operator error via manual inputs and verification. Reproducibility results showed that 5% of the average RPN between cohorts 1 and 2 was statistically different. Unexpected associations were noted between RPN and RT staff role; 12% of the physicist and therapist average scores were statistically different. Different levels of FMEA training yielded similar scoring within one RT department, suggesting a time-savings can be achieved with abbreviated training. Scores between professions, however, yielded significant differences suggesting the importance of involving staff across disciplines.


Assuntos
Análise do Modo e do Efeito de Falhas na Assistência à Saúde , Radiocirurgia , Neoplasias Unilaterais da Mama , Suspensão da Respiração , Humanos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Neoplasias Unilaterais da Mama/radioterapia
3.
J Appl Clin Med Phys ; 21(5): 48-55, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32196944

RESUMO

BACKGROUND AND PURPOSE: Multiple techniques can be used to assist with more accurate patient setup and monitoring during Stereotactic body radiation therapy (SBRT) treatment. This study analyzes the accuracy of 3D surface mapping with Surface-guided radiation therapy (SGRT) in detecting interfraction setup error and intrafraction motion during SBRT treatments of the lung and abdomen. MATERIALS AND METHODS: Seventy-one patients with 85 malignant thoracic or abdominal tumors treated with SBRT were analyzed. For initial patient setup, an alternating scheme of kV/kV imaging or SGRT was followed by cone beam computed tomography (CBCT) for more accurate tumor volumetric localization. The CBCT six degree shifts after initial setup with each method were recorded to assess interfraction setup error. Patients were then monitored continuously with SGRT during treatment. If an intrafractional shift in any direction >2 mm for longer than 2 sec was detected by SGRT, then CBCT was repeated and the recorded deltas were compared to those detected by SGRT. RESULTS: Interfractional shifts after SGRT setup and CBCT were small in all directions with mean values of <5 mm and < 0.5 degrees in all directions. Additionally, 25 patients had detected intrafraction motion by SGRT during a total of 34 fractions. This resulted in 25 (73.5%) additional shifts of at least 2 mm on subsequent CBCT. When comparing the average vector detected shift by SGRT to the resulting vector shift on subsequent CBCT, no significant difference was found between the two. CONCLUSIONS: Surface-guided radiation therapy provides initial setup within 5 mm for patients treated with SBRT and can be used in place of skin marks or planar kV imaging prior to CBCT. In addition, continuous monitoring with SGRT during treatment was valuable in detecting potentially clinically meaningful intrafraction motion and was comparable in magnitude to shifts from additional CBCT scans. PTV margin reduction may be feasible for SBRT in the lung and abdomen when using SGRT for continuous patient monitoring during treatment.


Assuntos
Radiocirurgia , Radioterapia Guiada por Imagem , Abdome/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Humanos , Pulmão , Movimento , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...