Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
World Neurosurg ; 187: 19-28, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38583569

RESUMO

BACKGROUND: Ventriculoscopic neuronavigation has been described in several articles. However, there are different ventriculoscopes and navigation systems. Due to these different combinations, it is difficult to find detailed neuronavigation protocols. We describe, step-by-step, a simple method to navigate both the trajectory until reaching the ventricular system, as well as the intraventricular work. METHODS: We use a rigid ventriculoscope (LOTTA, KarlStorz) with an electromagnetic stylet (S8-StealthSystem, Medtronic). The protocol is based on a modified or 3-dimensionally printed trocar for navigating the extraventricular step and on a modified pediatric nasogastric tube for the intraventricular navigation. RESULTS: This protocol can be set up in less than 10 minutes. The extraventricular part is navigated by introducing the electromagnetic stylet inside the modified or 3-dimensionally printed trocar. Intraventricular navigation is done by combining a modified pediatric nasogastric tube with the electromagnetic stylet inside the endoscope's working channel. The most critical point is to obtain a blunt-bloodless ventriculostomy while achieving perfect alignment of all targeted structures via pure straight trajectories. CONCLUSIONS: This protocol is easy-to-set-up, avoids head rigid-fixation and bulky optical-based attachments to the ventriculoscope, and allows continuous navigation of both parts of the surgery. Since we have implemented this protocol, we have noticed a significant enhancement in both simple and complex ventriculoscopic procedures because the surgery is dramatically simplified.


Assuntos
Neuroendoscópios , Neuroendoscopia , Neuronavegação , Ventriculostomia , Fluxo de Trabalho , Humanos , Neuronavegação/métodos , Neuronavegação/instrumentação , Neuroendoscopia/métodos , Neuroendoscopia/instrumentação , Ventriculostomia/métodos , Ventriculostomia/instrumentação , Fenômenos Eletromagnéticos , Impressão Tridimensional
2.
J Refract Surg ; 31(2): 90-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25735041

RESUMO

PURPOSE: To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). METHODS: A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin, Germany], enVista [Bausch & Lomb, Rochester, NY], and AcrySof IQ [Alcon Laboratories, Inc., Fort Worth, TX]) and one multifocal toric IOL (AcrySof IQ ReSTOR; Alcon Laboratories, Inc.) were implanted. Preoperative and postoperative images were taken to calculate the misalignment due to the marking method. To evaluate rotation in the different follow-up visits, another photograph was taken 1 hour and 1, 7 and 30 days postoperatively. Refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity were measured 30 days postoperatively. RESULTS: Postoperative UDVA was 0.1 logMAR or better in 64.6% of eyes implanted with monofocal IOLs and 46.4% of eyes implanted with multifocal IOLs. The enVista toric IOL showed the best UDVA compared to the other monofocal IOLs, with 81% of eyes with 0.1 logMAR or better. The mean misalignment in the total group studied was 0.07° ± 0.60°; 69.6% of monofocal IOLs and 67.9% of multifocal IOLs showed less than 5° of rotation. A correlation was found between postoperative UDVA and rotation in the monofocal and multifocal IOLs implanted (r = 0.439 [P < .011] and = 0.787 [P = .001], respectively). CONCLUSIONS: At 1 month postoperatively, UDVA was slightly more affected by IOL rotation in multifocal than monofocal toric IOLs. The marking method was also effective.


Assuntos
Migração do Implante de Lente Intraocular/diagnóstico , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Rotação , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/complicações , Astigmatismo/cirurgia , Catarata/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...