1.
Am J Cardiol ; 166: 88-96, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34949470

RESUMO

Our aim was to assess changes of right ventricular end-diastolic volumes (RVEDVi) and right ventricular ejection fraction (RVEF) in asymptomatic adults with repaired tetralogy of Fallot, with native right ventricular outflow tract and severe pulmonary regurgitation by serial cardiac magnetic resonance imaging (CMR). The study included 23 asymptomatic adults who underwent ≥3 CMR studies (total of 88 CMR studies). We compared changes in RVEDVi and RVEF between first and last study (median follow-up: 8.8 years, interquartile range: 6.3 to 13.1 years) and between all study pairs. Variability of measurements between study pairs (65 consecutive and 139 nonconsecutive CMR study pairs) were assessed using Bland-Altman analysis and intraclass correlation coefficients. On average, there were no significant changes of RVEDVi or RVEF over the study period (change in RVEDVi: +0.4 ± 17.8 ml/m2, change in RVEF: -1.0 ± 5.5%). Assessment of variability of measurements between study pairs demonstrated no systematic change in RVEDVi and RVEF between study pairs with limits of agreement within the range of previously published studies (RVEDVi -29.1 to +27.2 ml/m2; RVEF -11.5% to 10.2%). High intraclass correlation coefficients for RVEDVi (0.943, 95% CI 0.906 to 0.965, p <0.001) and RVEF (0.815, 95% CI 0.697 to 0.887, p <0.0001) indicate high reliability of reported measurements. In conclusion, in asymptomatic adults with repaired tetralogy of Fallot with native right ventricular outflow tracts and severe pulmonary regurgitation, CMR measurements of RV volumes and RVEF remain stable during follow-up with variability between CMR studies in individual patients, as expected for interobserver and interstudy variability. Measurements derived from a single CMR study or changes occurring between 2 CMR studies should be used with caution for clinical decision-making.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/etiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Função Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...