Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(1): 5-19, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38030885

RESUMO

The large volumes of samples to be analysed every day would be impossible to manage without laboratory automation. As laboratory procedures have progressed, so have the tasks of laboratory personnel. With this feature article, we would like to provide (bio)chemical practitioners with little or no knowledge of laboratory automation with a guide to help them decide whether to implement laboratory automation and find a suitable system. Especially in small- and medium-sized laboratories, operating a laboratory system means having bioanalytical knowledge, but also being familiar with the technical aspects. However, time, budget and personnel limitations allow little opportunity for personnel to get into the depths of laboratory automation. This includes not only the operation, but also the decision to purchase an automation system. Hasty investments do not only result in slow or non-existent cost recovery, but also occupy valuable laboratory space. We have structured the article as a decision tree, so readers can selectively read chapters that apply to their individual situation. This flexible approach allows each reader to create a personal reading flow tailored to their specific needs. We tried to address a variety of perspectives on the topic, including people who are either supportive or sceptical of laboratory automation, personnel who want or need to automate specific processes, those who are unsure whether to automate and those who are interested in automation but do not know which areas to prioritize. We also help to make a decision whether to reactivate or discard already existing and unused laboratory equipment.

2.
Sci Rep ; 13(1): 19451, 2023 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-37945580

RESUMO

Voice assistants are potentially helpful when working in a scientific laboratory. A big challenge is the extremely specific use of language in every laboratory. As with any voice assistant, another concern is data security. Here, we present Rainbow-an open source voice user interface (VUI) for scientific laboratories, that is adaptable to any Windows PC with Internet access. We used Google Translate Site (GTS) as a voice input and output system to ensure communication to the user. The scripting language AutoIt controls GTS, executes all actions and builds the VUI. Rainbow performs tasks from three different areas-general Microsoft Windows tasks, lab-specific tasks, and device-specific tasks. We achieved significantly higher speech recognition accuracy with our VUI than with GTS alone (91.3% versus 85.1%). Because of Rainbow's architecture, it is possible to improve the voice assistant in terms of functionality and accuracy, allowing each laboratory to optimize its own Rainbow system in a user-friendly way. In a test setup, this led to a speech recognition accuracy of 98.6%. Taken together, Rainbow provides an opportunity for every scientist to implement highly specific scientific terms and tasks to this open source voice assistant system in a very user-friendly way.


Assuntos
Percepção da Fala , Laboratórios , Ferramenta de Busca , Interface Usuário-Computador , Fala
3.
Protein Eng Des Sel ; 362023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-37903068

RESUMO

Most proteins are flexible molecules that coexist in an ensemble of several conformations. Point mutations in the amino acid sequence of a protein can trigger structural changes that drive the protein population to a conformation distinct from the native state. Here, we report a protein engineering approach to better understand protein dynamics and ligand binding of the FK506-binding protein 51 (FKBP51), a prospective target for stress-related diseases, metabolic disorders, some types of cancers and chronic pain. By randomizing selected regions of its ligand-binding domain and sorting yeast display libraries expressing these variants, mutants with high affinity to conformation-specific FKBP51 selective ligands were identified. These improved mutants are valuable tools for the discovery of novel selective ligands that preferentially and specifically bind the FKBP51 active site in its open conformation state. Moreover, they will help us understand the conformational dynamics and ligand binding mechanics of the FKBP51 binding pocket.


Assuntos
Engenharia de Proteínas , Proteínas de Ligação a Tacrolimo , Proteínas de Ligação a Tacrolimo/química , Ligantes , Sequência de Aminoácidos , Domínio Catalítico , Conformação Proteica , Ligação Proteica
4.
SLAS Technol ; 27(5): 312-318, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35830957

RESUMO

In most small laboratories, many processes are not yet automated because existing laboratory automation solutions are usually expensive and inflexible to use. Examples of this are autosamplers that are only compatible with one specific laboratory instrument or larger liquid handling stations that are expensive and usually self-contained. A flexible and inexpensive way to automate laboratory processes would be to automate existing laboratory equipment with the help of suitable robotic arms. In this study, we investigate the feasibility of such a strategy based on a low-cost 4-axis robot and freely available software. We used the scripting language AutoIt that automates any Windows-based instrument control software. Using these tools, we automated three fundamentally different laboratory processes: a pipetting process, a use as an autosampler for an atomic absorption spectroscopy instrument, and a more complex process involving the inoculation of bacterial cultures. We also integrated a conventional webcam for 2D barcode recognition. Compared to a trained professional who performed all experiments manually, all setups showed no significant differences in accuracy and precision. In summary, the tested system consisting of a 4-axis robot and freely available software is suitable for flexible automation and has potential for even more complex laboratory processes. Limitations such as a lack of collaboration and speed will be addressed in follow-up studies. The system thus represents a well-suited flexible laboratory automation system for both research and teaching purposes.


Assuntos
Automação Laboratorial , Robótica , Automação Laboratorial/métodos , Laboratórios , Software
5.
J Immunol ; 194(7): 3045-53, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25732729

RESUMO

The mechanisms underlying thymoma-associated immunodeficiency are largely unknown, and the significance of increased blood γδ Τ cells often remains elusive. In this study we address these questions based on an index patient with thymoma, chronic visceral leishmaniasis, myasthenia gravis, and a marked increase of rare γδ T cell subsets in the peripheral blood. This patient showed cutaneous anergy, even though he had normal numbers of peripheral blood total lymphocytes as well as CD4(+) and CD8(+) T cells. Despite his chronic infection, analyses of immunophenotypes and spectratyping of his lymphocytes revealed an unusual accumulation of naive γδ and αß T cells, suggesting a generalized T cell activation defect. Functional studies in vitro demonstrated substantially diminished IL-2 and IFN-γ production following TCR stimulation of his "untouched" naive CD4(+) T cells. Biochemical analysis revealed that his γδ and αß T cells carried an altered TCR complex with reduced amounts of the ζ-chain (CD247). No mutations were found in the CD247 gene that encodes the homodimeric ζ protein. The diminished presence of CD247 and increased numbers of γδ T cells were also observed in thymocyte populations obtained from three other thymoma patients. Thus, our findings describe a novel type of a clinically relevant acquired T cell immunodeficiency in thymoma patients that is distinct from Good's syndrome. Its characteristics are an accumulation of CD247-deficient, hyporresponsive naive γδ and αß T cells and an increased susceptibility to infections.


Assuntos
Complexo CD3/genética , Regulação da Expressão Gênica , Síndromes de Imunodeficiência/genética , Síndromes de Imunodeficiência/imunologia , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/metabolismo , Timoma/genética , Timoma/imunologia , Adulto , Antígenos de Protozoários/imunologia , Complexo CD3/metabolismo , Citocinas/biossíntese , Éxons , Humanos , Síndromes de Imunodeficiência/complicações , Síndromes de Imunodeficiência/diagnóstico , Memória Imunológica , Imunofenotipagem , Leishmania/imunologia , Contagem de Linfócitos , Masculino , Fenótipo , Doenças da Imunodeficiência Primária , Receptores de Antígenos de Linfócitos T alfa-beta/metabolismo , Receptores de Antígenos de Linfócitos T gama-delta/metabolismo , Análise de Sequência de DNA , Timoma/complicações , Timoma/diagnóstico
6.
J Cardiovasc Pharmacol ; 46(6): 842-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16306811

RESUMO

Soluble epoxide hydrolase (sEH) inhibitors have been demonstrated to have cardiovascular protective actions. This hydrolase enzyme converts fatty acid epoxides to their corresponding diols, and this conversion can alter the biologic activity of these metabolites. We hypothesized that 12-(3-adamantan-1-yl-ureido)dodecanoic acid (AUDA), a sEH inhibitor, would protect stroke-prone spontaneously hypertensive rats from cerebral ischemia. AUDA was administered to 6-week-old male rats for 6 weeks, during which blood pressure was measured by telemetry. Cerebral ischemia was induced by middle cerebral artery occlusion, the size of the cerebral infarct was assessed after 6 hours of ischemia, and the results were expressed as a percentage of the hemisphere infarcted (%HI). Vascular structure and function were assessed using a pressurized arteriograph. Plasma levels of AUDA at the end of the treatment period averaged 5.0 +/- 0.4 ng/mL, and the urinary excretion rate was 99 +/- 21 ng/d. AUDA-treated rats had significantly smaller cerebral infarcts than control rats (36 +/- 4% vs 53 +/- 4% HI, treated versus control, P < 0.05, n = 6). This difference occurred independently of changes in blood pressure. AUDA treatment increased the passive compliance of the cerebral vessels but had no effect on vascular structure. The results of this study provide novel evidence suggesting that the sEH inhibitor AUDA is a possible therapeutic agent for ischemic stroke.


Assuntos
Adamantano/análogos & derivados , Isquemia Encefálica/tratamento farmacológico , Infarto Cerebral/tratamento farmacológico , Inibidores Enzimáticos/uso terapêutico , Epóxido Hidrolases/antagonistas & inibidores , Hipertensão/complicações , Ácidos Láuricos/uso terapêutico , Fármacos Neuroprotetores/uso terapêutico , Adamantano/metabolismo , Adamantano/uso terapêutico , Animais , Compostos de Epóxi/sangue , Ácidos Láuricos/metabolismo , Masculino , Ratos , Ratos Endogâmicos SHR
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...