Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 5(7): 854-862, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31320015

RESUMO

OBJECTIVES: This study tested the hypothesis that a biphasic defibrillation waveform with an ascending first phase (ASC) causes less myocardial damage by pathology and injury current than a standard biphasic truncated exponential (BTE) waveform in a swine model. BACKGROUND: Although lifesaving, defibrillation shocks have significant iatrogenic effects that reduce their benefit for patient survival. METHODS: An ASC waveform with an 8-ms linear ramp followed by an additional positive 0.5-ms decaying portion with amplitudes of 20 J (ASC 20J) and 25 J (ASC 25J) was used. The control was a 25-J BTE conventional waveform (BTE 25J) RESULTS: The ASC 20J and ASC 25J shocks were both successful in 6 of 6 pigs, but the BTE 25J was successful in only 6 of 14 pigs (p < 0.05). Post-shock ST-segment elevation (injury current) in the right ventricular electrode was significantly greater with BTE 25J than with ASC 20J and ASC 25J. With a blinded pathology reading, hemorrhage, inflammation, thrombi, and necrosis 24 h post-shock were significantly greater with BTE 25J than with ASC 20J and ASC 25J. Troponin levels were also markedly lower at 3, 4, 5, and 6 h post-shock. CONCLUSIONS: Defibrillation shocks cause electrophysiological, histological, and biochemical signs of myocardial damage and necrosis. These signs of damage are markedly less for an ASC waveform than for a conventional BTE waveform.


Assuntos
Desfibriladores , Cardioversão Elétrica , Ventrículos do Coração , Miocárdio/patologia , Animais , Desfibriladores/efeitos adversos , Desfibriladores/normas , Modelos Animais de Doenças , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Cardioversão Elétrica/normas , Eletrocardiografia , Eletrodos , Feminino , Ventrículos do Coração/lesões , Ventrículos do Coração/fisiopatologia , Masculino , Necrose/etiologia , Suínos , Troponina C/sangue
2.
Circulation ; 126(11): 1328-33, 2012 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-22865891

RESUMO

BACKGROUND: We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. METHODS AND RESULTS: Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform-in 6 pigs with electrodes in the right ventricular apex and superior vena cava. The ascending, descending, and rectilinear waveforms had 4-, 8-, and 16-millisecond first phases and a 3.5-millisecond rectilinear second phase that was half the voltage of the first phase. The exponential biphasic waveform had a 60% first-phase and a 50% second-phase tilt. In a second study, we attempted to defibrillate after 10 seconds of ventricular fibrillation with a single ≈30-J shock (6 pigs successfully defibrillated with 8-millisecond ascending, 8-millisecond rectilinear, and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hours after the shock. The lowest-energy defibrillation threshold was for the 8-milliseconds ascending ramp (14.6±7.3 J [mean±SD]), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours after shock, troponin I was significantly less for the ascending-ramp waveform (0.80±0.54 ng/mL) than for the truncated exponential (1.92±0.47 ng/mL) or the rectilinear waveform (1.17±0.45 ng/mL). CONCLUSIONS: The ascending ramp has a significantly lower defibrillation threshold and at ≈30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the defibrillation threshold and the amount of cardiac damage.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Radiação Eletromagnética/classificação , Troponina I/sangue , Fibrilação Ventricular/terapia , Animais , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/métodos , Eletrodos , Feminino , Traumatismos Cardíacos/etiologia , Ventrículos do Coração/fisiopatologia , Masculino , Modelos Animais , Suínos , Fatores de Tempo , Veia Cava Superior/fisiopatologia , Fibrilação Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...