Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Polymers (Basel) ; 14(11)2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35683861

RESUMO

The selection of biomaterials as biomedical implants is a significant challenge. Ultra-high molecular weight polyethylene (UHMWPE) and composites of such kind have been extensively used in medical implants, notably in the bearings of the hip, knee, and other joint prostheses, owing to its biocompatibility and high wear resistance. For the Anterior Cruciate Ligament (ACL) graft, synthetic UHMWPE is an ideal candidate due to its biocompatibility and extremely high tensile strength. However, significant problems are observed in UHMWPE based implants, such as wear debris and oxidative degradation. To resolve the issue of wear and to enhance the life of UHMWPE as an implant, in recent years, this field has witnessed numerous innovative methodologies such as biofunctionalization or high temperature melting of UHMWPE to enhance its toughness and strength. The surface functionalization/modification/treatment of UHMWPE is very challenging as it requires optimizing many variables, such as surface tension and wettability, active functional groups on the surface, irradiation, and protein immobilization to successfully improve the mechanical properties of UHMWPE and reduce or eliminate the wear or osteolysis of the UHMWPE implant. Despite these difficulties, several surface roughening, functionalization, and irradiation processing technologies have been developed and applied in the recent past. The basic research and direct industrial applications of such material improvement technology are very significant, as evidenced by the significant number of published papers and patents. However, the available literature on research methodology and techniques related to material property enhancement and protection from wear of UHMWPE is disseminated, and there is a lack of a comprehensive source for the research community to access information on the subject matter. Here we provide an overview of recent developments and core challenges in the surface modification/functionalization/irradiation of UHMWPE and apply these findings to the case study of UHMWPE for ACL repair.

2.
ANZ J Surg ; 91(6): 1226-1232, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33021022

RESUMO

BACKGROUND: To clinically evaluate 3D print-formed implant process, using cranioplasty as a proof of concept, to examine its effectiveness and utility as a method of intraoperative implant fabrication. METHODS: Twelve patients had a 3D print-formed template created for patient-specific implant manufacture. Of these patients, 10 received intraoperatively formed polymethylmethacrylate cranioplasty implants between 2013 and 2019. The 3D print-formed implant templates produced to manufacture these patient-specific implants were generated using patient computed tomography scans and 3D printed using fused deposition modelling technology. Cosmetic and functional results were determined by participating surgeons, in conjunction with a patient questionnaire. RESULTS: The functional results and stability of the implants were deemed to be favourable by participating surgeons. Three of the 10 patients completed a post-cranioplasty survey, all of whom judged their cosmetic results as good or excellent. At time of writing, the rate of surgical revision was zero and without clinically adverse outcomes. CONCLUSIONS: 3D print-formed implants are an effective method of patient-specific implant formation.


Assuntos
Procedimentos de Cirurgia Plástica , Impressão Tridimensional , Humanos , Polimetil Metacrilato , Próteses e Implantes , Crânio/diagnóstico por imagem , Crânio/cirurgia
3.
J Mech Behav Biomed Mater ; 108: 103760, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32469712

RESUMO

AIM: A two-body wear test experiment was performed on human enamel, in simulated chewing motion, against non-veneered zirconia ceramic. Aim-1 was to ascertain the effect of zirconia roughness on enamel wear. Aim-2 was to ascertain the relative enamel wear between enamel-zirconia wear pair and enamel-enamel control pair. MATERIALS: Six molar and premolar human enamel cusps per group were used for a dental wear test against laboratory polished (LP) zirconia and laboratory polished and clinically adjusted (LP + CA) zirconia. Enamel antagonists were tested against incisor teeth as a control group to demonstrate laboratory enamel wear. METHODOLOGY: Two-body wear tests were conducted in a dual-axis biomimetic dental wear simulator. 49N loading force was used for 120,000 cycles with 1 mm lateral movement of the test specimen at 1.6Hz frequency, under constant ambient temperature water flow. Surface roughness before testing was determined using 3D profilometry. Loss of enamel height and volume i.e. vertical wear and volumetric wear respectively, were measured by superimposition of before and after testing scans by 3D laser scanning. Scanning electron microscopy was used for surface morphology assessment. One-way ANOVA and Post Hoc Multiple Comparisons with Bonferroni corrections were used at the 5% significance level to determine whether surface finish affected volumetric and vertical enamel loss. The relationship between volumetric and vertical loss of enamel was assessed using Pearson's correlation test. RESULTS: No significant difference was found between LP and LP + CA zirconia in vertical and volumetric enamel wear results. Control enamel had significantly higher vertical and volumetric enamel wear than LP and LP + CA zirconia. Pearson correlation revealed a strong relationship between vertical wear and volumetric wear of enamel. CONCLUSION: Within the constraints of the test method in this experiment, zirconia irrespective of surface preparation, was found to cause less vertical and volumetric enamel wear compared to control enamel. No statistically significant difference was seen between LP zirconia and LP + CA zirconia.


Assuntos
Laboratórios , Zircônio , Esmalte Dentário , Porcelana Dentária , Desgaste de Restauração Dentária , Humanos , Teste de Materiais , Propriedades de Superfície
4.
Disabil Rehabil Assist Technol ; 15(1): 37-44, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30394146

RESUMO

Aim: Functional electrical stimulation (FES) is a technology that can be used on paralyzed muscles to allow them to move. It has been used in populations with muscle paralysis or weakness for exercise, such as spinal cord injury (SCI) and multiple sclerosis. In order to improve technology, it is vital to understand from a qualitative perspective, issues surrounding device development and implementation.Materials and Methods: In 2016, a study was conducted at the Medical University of Vienna that sought to unravel perspectives of FES exercise from the perspective of clinicians, engineers and researchers. Semi-structured, qualitative interviews were conducted on a sample of participants from the conference (n = 22). Interviews were transcribed verbatim, and text data were analysed.Results: Following this analysis, a conceptual model of FES application in the home environment was derived. We show that the likelihood of continuing FES over time may be influenced by expectations and initial education, as perceived by stakeholders.Conclusion: This model provides a tool by which researchers or clinicians may implement FES in the home environment and may assist in the increased uptake of FES exercise at home for people who may reap benefits from its use.Implications for RehabilitationFunctional electrical stimulation (FES) is a technology that enables individuals with paralysis, such as Spinal Cord Injury or Multiple Sclerosis, to exercise.Motivation and support networks, along with adequate initial education, are essential should patients be able to successfully use FES for exercise.There are unique issues associated with performing FES in the home, and compliance may be influenced by how patients perceive FES with regard to providing benefits, and what their initial expectations are.Communication and education are essential for all parties involved in the provision of FES treatment, to ensure successful treatment with FES at home.


Assuntos
Terapia por Estimulação Elétrica , Terapia por Exercício/instrumentação , Esclerose Múltipla/reabilitação , Traumatismos da Medula Espinal/reabilitação , Participação dos Interessados , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Materials (Basel) ; 12(6)2019 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-30893909

RESUMO

In this study, a fibrous composite was developed as synthetic graft for labral reconstruction treatment, comprised of ultra-high molecular weight polyethylene (UHMWPE) fabric, ultrafine fibre of polycaprolactone (PCL), and 45S5 Bioglass®. This experiment aimed to examine the mechanical performance and cytocompatibility of the composite. Electrospinning and a slurry dipping technique were applied for composite fabrication. To assess the mechanical performance of UHMWPE, tensile cyclic loading test was carried out. Meanwhile, cytocompatibility of the composite on fibroblastic cells was examined through a viability assay, as well as SEM images to observe cell attachment and proliferation. The mechanical test showed that the UHMWPE fabric had a mean displacement of 1.038 mm after 600 cycles, approximately 4.5 times greater resistance compared to that of natural labrum, based on data obtained from literature. A viability assay demonstrated the predominant occupation of live cells on the material surface, suggesting that the composite was able to provide a viable environment for cell growth. Meanwhile, SEM images exhibited cell adhesion and the formation of cell colonies on the material surface. These results indicated that the UHMWPE/PCL/Bioglass® composite could be a promising material for labrum implants.

6.
Eur J Transl Myol ; 29(4): 8285, 2019 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-31969976

RESUMO

This review of literature focuses on the multiple uses of Functional Electrical Stimulation (FES) and how this modality may be a valuable home-based therapy. Papers pertaining to home FES exercise were collected using the Web of Science, Google Scholar databases and collegial hints. In our opinion, the following statements summarize the results. FES may be used to induce health benefits in populations with paralysis, and in persons with musculoskeletal, cardiorespiratory and renal pathology. The EU Project Rise showed how FES could have a variety of encouraging outcomes for patients with denervated muscles following traumatic injuries. As suggested by recent literature, FES has proven to be a viable form of exercise for elderly individuals. Thus, Home FES may be an option for patients looking for an additional form of muscle and cardiopulmonary physical therapy.

7.
J Arthroplasty ; 33(9): 2843-2850, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29807792

RESUMO

BACKGROUND: Component alignment variation following total knee arthroplasty (TKA) does not fully explain the instance of long-term postoperative pain. Joint dynamics following TKA vary with component alignment and patient-specific musculoskeletal anatomy. Computational simulations allow joint dynamics outcomes to be studied across populations. This study aims to determine if simulated postoperative TKA joint dynamics correlate with patient-reported outcomes. METHODS: Landmarking and 3D registration of implants was performed on 96 segmented postoperative computed tomography scans of TKAs. A cadaver rig-validated platform for generating patient-specific simulation of deep knee bend kinematics was run for each patient. Resultant dynamic outcomes were correlated with a 12-month postoperative Knee Injury and Osteoarthritis Outcome Score (KOOS). A Classification and Regression Tree (CART) was used for determining nonlinear relationships. RESULTS: Nonlinear relationships between the KOOS pain score and rollback and dynamic coronal alignment were found to be significant. Combining a dynamic coronal angular change from extension to full flexion between 0° and 4° varus (long leg axis) and measured rollback of no more than 6 mm without rollforward formed a "kinematic safe zone" of outcomes in which the postoperative KOOS score is 10.5 points higher (P = .013). CONCLUSION: The study showed statistically significant correlations between kinematic factors in a simulation of postoperative TKA and postoperative KOOS scores. The presence of a dynamic safe zone in the data suggests a potential optimal target for any given individual patient's joint dynamics and the opportunity to preoperatively determine a patient-specific alignment target to achieve those joint dynamics.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Idoso , Fenômenos Biomecânicos , Simulação por Computador , Feminino , Humanos , Imageamento Tridimensional , Traumatismos do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Amplitude de Movimento Articular , Sistema de Registros , Tomografia Computadorizada por Raios X
8.
Materials (Basel) ; 11(3)2018 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-29562614

RESUMO

Electrospun fibres have gained broad interest in biomedical applications, including tissue engineering scaffolds, due to their potential in mimicking extracellular matrix and producing structures favourable for cell and tissue growth. The development of scaffolds often involves multivariate production parameters and multiple output characteristics to define product quality. In this study on electrospinning of polycaprolactone (PCL), response surface methodology (RSM) was applied to investigate the determining parameters and find optimal settings to achieve the desired properties of fibrous scaffold for acetabular labrum implant. The results showed that solution concentration influenced fibre diameter, while elastic modulus was determined by solution concentration, flow rate, temperature, collector rotation speed, and interaction between concentration and temperature. Relationships between these variables and outputs were modelled, followed by an optimization procedure. Using the optimized setting (solution concentration of 10% w/v, flow rate of 4.5 mL/h, temperature of 45 °C, and collector rotation speed of 1500 RPM), a target elastic modulus of 25 MPa could be achieved at a minimum possible fibre diameter (1.39 ± 0.20 µm). This work demonstrated that multivariate factors of production parameters and multiple responses can be investigated, modelled, and optimized using RSM.

9.
J Arthroplasty ; 33(1): 67-74, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28927560

RESUMO

BACKGROUND: Optimal rotational alignment of the femoral component is a common goal during total knee arthroplasty. The posterior condylar axis (PCA) is thought to be the most reproducible reference in surgery, while the transepicondylar axis (TEA) seems to better approximate the native kinematic flexion axis. This study sought to determine if rules based on patient gender or coronal alignment could allow reliable reproduction of the TEA from the PCA. METHODS: Three-dimensional models based on preoperative computed tomography were made representing a patient's arthritic knee joint. The landmarks were defined and angular relationships determined. RESULTS: The population group of 726 patients contained large anatomic variation. When applying the standard reference rule of 3° external rotation from the PCA, 36.9% of patients would have a rotational target greater than ±2° from their TEA. When applying the mean external rotation of the TEA from the PCA (1.85°) from this population, this proportion dropped to 26.0% of patients. The use of statistically significant gender and coronal alignment relationships to define the femoral rotation did not reduce the proportion of patients in ±2° error. CONCLUSION: This study shows that gender and coronal alignment relationships to the TEA to PCA angle are not clinically significant as a quarter of patients would still have a target for rotation greater than ±2° from the TEA using these relationships. Superior tools for orienting rotational cuts directly to the TEA in surgery or preoperative identification of relevant patient-specific angles might capture the proportion of patients for whom standard reference angles are not appropriate.


Assuntos
Artroplastia do Joelho , Fêmur/anatomia & histologia , Fêmur/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Rotação , Tomografia Computadorizada por Raios X
10.
Eur J Transl Myol ; 28(4): 7732, 2018 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-30662695

RESUMO

There are several parameters that can be modulated during electrical stimulation-induced muscle contraction to obtain external work, i.e., Functional Electrical Stimulation (FES). The literature has several reports of the relationships of parameters such as frequency, pulse width, amplitude and physiological or biomechanical outcomes (i.e., torque) when these parameters are changed. While these relationships are well-described, lesser known across the literature is how changing the duty cycle (time ON and time OFF) of stimulation affects the outcomes. This review provides an analysis of the literature pertaining to the duty cycle in electrical stimulation experiments. There are two distinct sections of this review - an introduction to the duty cycle and definitions from literature (part I); and contentions from the literature and proposed frameworks upon which duty cycle can be interpreted (part II). It is envisaged that the two reviews will highlight the importance of modulating the duty cycle in terms of muscle fatigue in mimicking physiological activities. The frameworks provided will ideally assist in unifying how researchers consider the duty cycle in electrical stimulation (ES) of muscles.

11.
Eur J Transl Myol ; 28(4): 7733, 2018 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-30662696

RESUMO

In part I of this review, we introduced the duty cycle as a fundamental parameter in controlling the effect of electrical stimulation pulse trains on muscle structural and functional properties with special emphasis on fatigue. Following on from a survey of the literature, we discuss here the relative ability of intermittent and continuous stimulation to fatigue muscle. In addition, pertinent literature is explored on a more deeper level, highlighting contentions regarding the duty cycle across studies. In response to literature inconsistencies, we propose frameworks upon which the duty cycle parameter may be specified. We present the idea of domain reporting for the duty cycle, and illustrate with practical examples. In addition we dig further into the literature and present a set of notations that have been used by different researchers to report the duty cycle. We also propose the idea of the duty cycle multiple, which together with domain reporting, will help researchers understand more precisely duty cycles of electrical stimulation. As a case study, we also show how the duty cycle has been looked at by researchers in the context of pressure sore attenuation in patients. Together with part I, it is hoped that the frameworks suggested provide a complete picture of how duty cycle has been discussed across the literature, and gives researchers a more trans-theoretical basis upon which they may report the duty cycle in their studies. This may also lead to a more precise specification of electrical stimulation protocols used in patients.

12.
J Biophotonics ; 11(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29227574

RESUMO

Nail fungal infections are notoriously persistent and difficult to treat which can lead to severe health impacts, particularly in the immunocompromized. Current antifungal treatments, including systemic and topical drugs, are prolonged and do not effectively provide a complete cure. Severe side effects are also associated with systemic antifungals, such as hepatotoxicity. Light treatments of onychomycosis are an emerging therapy that has localized photodynamic, photothermal or photoablative action. These treatments have shown to be an effective alternative to traditional antifungal remedies with comparable or better cure rates achieved in shorter times and without systemic side effects. This report reviews significant clinical and experimental studies in the field, highlighting mechanisms of action and major effects related to light therapy; in particular, the impact of light on fungal genetics.


Assuntos
Micoses/terapia , Unhas/microbiologia , Fototerapia/métodos , Humanos
13.
Eur J Transl Myol ; 27(3): 6604, 2017 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-29118956

RESUMO

Functional Electrical Stimulation (FES) is the production of electrically elicited muscle contractions to perform a function or task. It has been used as a method to regain lost body functions or support weak body functions, and as such, has been clinically available since the early seventies. Some methods are applied routinely while others have not been translated to the bedside, or are still largely restricted to laboratory use. Progress in this field might be achieved by a strong cooperation of patients, clinicians, therapists and engineers. A better insight into multiple perspectives may help in understanding the shortcomings of current FES technology. This will help direct future research efforts into design of systems and potential application in relevant populations. In addition, these findings can assist with the translation of FES technology into a community context. We outline an interview protocol designed for use at the 12th Vienna International Workshop on Functional Electrical Stimulation where the mentioned experts from the field of FES met.

14.
Proc Inst Mech Eng H ; 230(7): 668-74, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27098752

RESUMO

Peri-prosthetic femoral neck fracture after femoral head resurfacing can be either patient-related or surgical technique-related. The study aimed to develop a patient-specific finite element modelling technique that can reliably predict an optimal implant position and give minimal strain in the peri-prosthetic bone tissue, thereby reducing the risk of peri-prosthetic femoral neck fracture. The subject-specific finite element modelling was integrated with optimization techniques including design of experiments to best possibly position the implant for achieving minimal strain for femoral head resurfacing. Sample space was defined by varying the floating point to find the extremes at which the cylindrical reaming operation actually cuts into the femoral neck causing a notch during hip resurfacing surgery. The study showed that the location of the maximum strain, for all non-notching positions, was on the superior femoral neck, in the peri-prosthetic bone tissue. It demonstrated that varus positioning resulted in a higher strain, while valgus positioning reduced the strain, and further that neutral version had a lower strain.


Assuntos
Artroplastia de Quadril/métodos , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Fenômenos Biomecânicos , Fraturas do Colo Femoral/prevenção & controle , Cabeça do Fêmur/diagnóstico por imagem , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiopatologia , Colo do Fêmur/cirurgia , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Modelos Anatômicos , Tomografia Computadorizada por Raios X
15.
ACS Appl Mater Interfaces ; 8(11): 6802-10, 2016 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-26928086

RESUMO

Biomaterials with the ability to interface with, but not activate, blood components are essential for a multitude of medical devices. Diamond-like carbon (DLC) and titania (TiO2) have shown promise for these applications; however, both support platelet adhesion and activation. This study explored the fabrication of nanostructured DLC and TiO2 thin film coatings using a block copolymer deposition technique that produced semiordered nanopatterns with low surface roughness (5-8 nm Rrms). These surfaces supported fibrinogen and plasma protein adsorption that predominantly adsorbed between the nanofeatures and reduced the overall surface roughness. The conformation of the adsorbed fibrinogen was altered on the nanopatterned surfaces as compared with the planar surfaces to reveal higher levels of the platelet binding region. Planar DLC and TiO2 coatings supported less platelet adhesion than nanopatterned DLC and TiO2. However, platelets on the nanopatterned DLC coatings were less spread indicating a lower level of platelet activation on the nanostructured DLC coatings compared with the planar DLC coatings. These data indicated that nanostructured DLC coatings may find application in blood contacting medical devices in the future.


Assuntos
Plaquetas/metabolismo , Materiais Revestidos Biocompatíveis/química , Membranas Artificiais , Nanodiamantes/química , Adesividade Plaquetária , Titânio/química , Adulto , Feminino , Humanos , Masculino
16.
Biomed Mater Eng ; 25(3): 267-78, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26407113

RESUMO

BACKGROUND: The design of femoral component used in total hip arthroplasty is known to influence the incidence of periprosthetic femoral fractures (PFFs) in cementless hip arthroplasty. OBJECTIVE: This study was undertaken to determine if 2 potential changes to an existing ABG II-standard cementless implant - addition of a roughened titanium plasma-sprayed proximal coating (ABG II-plasma) and lack of medial scales (ABG II-NMS) could decrease the risk of PFF in the intraoperative and early postoperative periods. METHODS: Six pairs of human cadaveric femurs were harvested and divided into 2 groups, each receiving either of the altered implants and ABG II-standard (control). Each implant was tested in a biomechanical setup in a single-legged stance orientation. Surface strains were measured in intact femurs, during implant insertion, cyclic loading of the bone with the implant, and loading to failure. Strains with the ABG II-standard and the altered implants were compared. FINDINGS: ABG II-plasma showed better load-bearing capacity, with an average 42% greater failure load than that of ABG II-standard. The cortical hoop, axial and mean strains ABG II-plasma were less than those of ABG II-standard, demonstrating decreased tensile behaviour and better load transfer to the proximal femur. The final residual hoop strains in ABG II-plasma were closer to those of intact bone as compared to the standard stem. No differences in strains were observed between the standard stem and ABG II-NMS. CONCLUSION: The increased load-bearing capacity and decreased proximal surface strains on femurs implanted with ABG II-plasma stem should reduce the risks of intraoperative and early postoperative PFF.


Assuntos
Fraturas do Fêmur/prevenção & controle , Fraturas do Fêmur/fisiopatologia , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/prevenção & controle , Fraturas Periprotéticas/fisiopatologia , Titânio/química , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cadáver , Cimentação , Materiais Revestidos Biocompatíveis/síntese química , Força Compressiva , Módulo de Elasticidade , Análise de Falha de Equipamento , Feminino , Fraturas do Fêmur/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/etiologia , Gases em Plasma/química , Desenho de Prótese , Medição de Risco , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Resultado do Tratamento
17.
Med Eng Phys ; 37(6): 567-73, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25937546

RESUMO

Subject-specific finite element (FE) modeling methodology could predict peri-prosthetic femoral fracture (PFF) for cementless hip arthoplasty in the early postoperative period. This study develops methodology for subject-specific finite element modeling by using the element deactivation technique to simulate bone failure and validate with experimental testing, thereby predicting peri-prosthetic femoral fracture in the early postoperative period. Material assignments for biphasic and triphasic models were undertaken. Failure modeling with the element deactivation feature available in ABAQUS 6.9 was used to simulate a crack initiation and propagation in the bony tissue based upon a threshold of fracture strain. The crack mode for the biphasic models was very similar to the experimental testing crack mode, with a similar shape and path of the crack. The fracture load is sensitive to the friction coefficient at the implant-bony interface. The development of a novel technique to simulate bone failure by element deactivation of subject-specific finite element models could aid prediction of fracture load in addition to fracture risk characterization for PFF.


Assuntos
Simulação por Computador , Fraturas do Fêmur , Prótese de Quadril , Modelos Biológicos , Fraturas Periprotéticas , Fraturas do Fêmur/fisiopatologia , Fêmur/fisiopatologia , Análise de Elementos Finitos , Fricção , Humanos , Fraturas Periprotéticas/fisiopatologia , Falha de Prótese
18.
Proc Inst Mech Eng H ; 229(4): 280-90, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25934257

RESUMO

Intra-operative peri-prosthetic femoral fractures are a significant concern in total hip arthroplasty and can occur at any time during surgery, with the highest incidence during implant insertion. This study combines subject-specific finite element analysis modeling with an optical tracking system to characterize the resultant strain in the bone and results of impaction during total hip replacement surgery. The use of ABG II femoral stem (Stryker Orthopaedics, Mahwah, NJ, USA) in the model yielded the following results. Hammer velocity was measured experimentally using a three-dimensional optical tracking system and these data were input into the finite element analysis model so that intra-operative loading scenario could be simulated. A quasi-static explicit simulation and a dynamic loading step using two implant-bone interface friction (0.1 and 0.4 friction coefficients) states were simulated. The maximum swing velocity of a mallet was experimentally measured at 1.5 m/s and occurred just before impaction of the hammer with implant introducer. Two friction states resulted in different results with the lower friction coefficient generating higher strains in the anterior regions of the model and higher displacement of the implant with respect to the femur when compared to the high friction state.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Simulação por Computador , Análise de Elementos Finitos , Fricção , Humanos , Desenho de Prótese , Estresse Mecânico
19.
Materials (Basel) ; 8(3): 1074-1088, 2015 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-28787989

RESUMO

Foamed alumina was previously synthesised by direct foaming of sulphate salt blends varying ammonium mole fraction (AMF), foaming heating rate and sintering temperature. The optimal product was produced with 0.33AMF, foaming at 100 °C/h and sintering at 1600 °C. This product attained high porosity of 94.39%, large average pore size of 300 µm and the highest compressive strength of 384 kPa. To improve bioactivity, doping of porous alumina by soaking in dilute or saturated solutions of Ca, P, Mg, CaP or CaP + Mg was done. Saturated solutions of Ca, P, Mg, CaP and CaP + Mg were made with excess salt in distilled water and decanted. Dilute solutions were made by diluting the 100% solution to 10% concentration. Doping with Si was done using the sol gel method at 100% concentration only. Cell culture was carried out with MG63 osteosarcoma cells. Cellular response to the Si and P doped samples was positive with high cell populations and cell layer formation. The impact of doping with phosphate produced a result not previously reported. The cellular response showed that both Si and P doping improved the biocompatibility of the foamed alumina.

20.
Materials (Basel) ; 8(7): 4344-4362, 2015 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-28793444

RESUMO

Zirconia-toughened alumina (ZTA) using yttria-stabilised zirconia is a good option for ceramic-ceramic bearing couples for hip joint replacement. Gelcasting is a colloidal processing technique capable of producing complex products with a range of dimensions and materials by a relatively low-cost production process. Using gelcasting, ZTA samples were prepared, optimising the stages of fabrication, including slurry preparation with varying solid loadings, moulding and de-moulding, drying and sintering. Density, hardness, fracture toughness, flexural strength and grain size were observed relative to slurry solid loadings between 58 and 62 vol. %, as well as sintering temperatures of 1550 °C and 1650 °C. Optimal conditions found were plastic mould, 4000 g/mol PEG with 30 vol. % concentration, 61% solid loading and Ts = 1550 °C. ZTA samples of high density (maximum 99.1%), high hardness (maximum 1902 HV), high fracture toughness (maximum 5.43 MPa m1/2) and high flexural strength (maximum 618 MPa) were successfully prepared by gelcasting and pressureless sintering.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...