Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Interv Cardiol Clin ; 13(3): 421-430, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839174

RESUMO

Since PDA stenting was first attempted in the early 1990s, significant technical advancements have improved outcomes and some centers have even transitioned to exclusive PDA stenting for all infants with duct-dependent pulmonary circulation. In addition to its use in infants with duct-dependent pulmonary circulation, PDA stenting has also been adapted as a percutaneous palliative option for suprasystemic pulmonary arterial hypertension and as a component of the hybrid procedure. In this article, the authors aim to review indications and outcomes for PDA stenting, describe the procedure, and discuss future directions.


Assuntos
Permeabilidade do Canal Arterial , Stents , Humanos , Permeabilidade do Canal Arterial/cirurgia , Cateterismo Cardíaco/métodos , Cuidados Paliativos/métodos , Resultado do Tratamento
2.
3D Print Med ; 10(1): 3, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38282094

RESUMO

BACKGROUND: The use of medical 3D printing (focusing on anatomical modeling) has continued to grow since the Radiological Society of North America's (RSNA) 3D Printing Special Interest Group (3DPSIG) released its initial guideline and appropriateness rating document in 2018. The 3DPSIG formed a focused writing group to provide updated appropriateness ratings for 3D printing anatomical models across a variety of congenital heart disease. Evidence-based- (where available) and expert-consensus-driven appropriateness ratings are provided for twenty-eight congenital heart lesion categories. METHODS: A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with pediatric congenital heart disease indications. Each study was vetted by the authors and strength of evidence was assessed according to published appropriateness ratings. RESULTS: Evidence-based recommendations for when 3D printing is appropriate are provided for pediatric congenital heart lesions. Recommendations are provided in accordance with strength of evidence of publications corresponding to each cardiac clinical scenario combined with expert opinion from members of the 3DPSIG. CONCLUSIONS: This consensus appropriateness ratings document, created by the members of the RSNA 3DPSIG, provides a reference for clinical standards of 3D printing for pediatric congenital heart disease clinical scenarios.

3.
3D Print Med ; 9(1): 34, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38032479

RESUMO

BACKGROUND: Medical three-dimensional (3D) printing has demonstrated utility and value in anatomic models for vascular conditions. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (3DPSIG) provides appropriateness recommendations for vascular 3D printing indications. METHODS: A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with vascular indications. Each study was vetted by the authors and strength of evidence was assessed according to published appropriateness ratings. RESULTS: Evidence-based recommendations for when 3D printing is appropriate are provided for the following areas: aneurysm, dissection, extremity vascular disease, other arterial diseases, acute venous thromboembolic disease, venous disorders, lymphedema, congenital vascular malformations, vascular trauma, vascular tumors, visceral vasculature for surgical planning, dialysis access, vascular research/development and modeling, and other vasculopathy. Recommendations are provided in accordance with strength of evidence of publications corresponding to each vascular condition combined with expert opinion from members of the 3DPSIG. CONCLUSION: This consensus appropriateness ratings document, created by the members of the 3DPSIG, provides an updated reference for clinical standards of 3D printing for the care of patients with vascular conditions.

4.
JACC Case Rep ; 10: 101760, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36974056

RESUMO

The authors report a closed-chest, transcatheter large-vessel connection (hepatic conduit to azygous vein) to reverse pulmonary arteriovenous malformations in a 10-year-old patient after Fontan for heterotaxy/interrupted inferior vena cava, with an increase in oxygen saturation from 78% to 96%. Computational fluid dynamics estimated a 14-fold increase in hepatic blood flow to the left pulmonary artery (from 1.3% to 14%). (Level of Difficulty: Advanced.).

5.
3D Print Med ; 9(1): 8, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36952139

RESUMO

The use of medical 3D printing has expanded dramatically for breast diseases. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides updated appropriateness criteria for breast 3D printing in various clinical scenarios. Evidence-based appropriateness criteria are provided for the following clinical scenarios: benign breast lesions and high-risk breast lesions, breast cancer, breast reconstruction, and breast radiation (treatment planning and radiation delivery).

6.
Cardiovasc Revasc Med ; 34: 128-133, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33526391

RESUMO

BACKGROUND/PURPOSE: Patients with a functional single ventricle undergo multiple, palliative open-heart surgeries. This includes a superior cavopulmonary anastomosis or bidirectional Glenn shunt. A less-invasive transcatheter approach may reduce morbidity. METHODS/MATERIALS: We analyzed pre-Glenn X-ray contrast angiography (XA), cardiac computed tomography (CT), and cardiac magnetic resonance (CMR) studies. RESULTS: Over an eleven-year period (1/2007 - 6/2017), 139 Glenn surgeries were performed at our institution. The typical age range at surgery was 59 - 371 days (median = 163; IQR = 138 - 203). Eight-nine XA, ten CT, and ten CMR studies obtained from these patients were analyzed. Cephalad SVC measurements (millimeters) were 7.3 ± 1.7 (XA), 7.7 ± 1.6 (CT) and 6.9 ± 1.8 (CMR). RPA measurements were 7.3 ± 1.9 (XA), 7.4 ± 1.6 (CT) and 6.6 ± 1.9 (CMR). Potential device lengths were 10.9 ± 6 - 17.4 ± 6.4 (XA), 10.1 ± 2.1 - 17.7 ± 2.4 (CT) and 17.3 ± 4. - 23.7 ± 5.5 (CMR). SVC-RPA angle (degrees) was 132.9 ± 13.2 (CT) and 140 ± 10.2 (MRI). Image quality of all CT (100%), almost all XA (SVC 100%, RPA 99%), and most MRI (SVC 80%, RPA 90%) were deemed sufficient. Parametric modeling virtual fit device with 10 mm diameter and 20 - 25 mm length was ideal. CONCLUSIONS: Ideal transcatheter cavopulmonary shunt device for the typical patient would be 10 mm in diameter and 20-25 mm in length.


Assuntos
Técnica de Fontan , Derivação Cardíaca Direita , Cardiopatias Congênitas , Técnica de Fontan/efeitos adversos , Técnica de Fontan/métodos , Derivação Cardíaca Direita/efeitos adversos , Derivação Cardíaca Direita/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Imagem Multimodal , Artéria Pulmonar , Estudos Retrospectivos
7.
Cell Rep Med ; 2(7): 100348, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34337564

RESUMO

3D visualization technologies such as virtual reality (VR), augmented reality (AR), and mixed reality (MR) have gained popularity in the recent decade. Digital extended reality (XR) technologies have been adopted in various domains ranging from entertainment to education because of their accessibility and affordability. XR modalities create an immersive experience, enabling 3D visualization of the content without a conventional 2D display constraint. Here, we provide a perspective on XR in current biomedical applications and demonstrate case studies using cell biology concepts, multiplexed proteomics images, surgical data for heart operations, and cardiac 3D models. Emerging challenges associated with XR technologies in the context of adverse health effects and a cost comparison of distinct platforms are discussed. The presented XR platforms will be useful for biomedical education, medical training, surgical guidance, and molecular data visualization to enhance trainees' and students' learning, medical operation accuracy, and the comprehensibility of complex biological systems.


Assuntos
Realidade Aumentada , Tecnologia Biomédica , Realidade Virtual , Tecnologia Biomédica/economia , Custos e Análise de Custo , Emoções , Humanos , Aprendizagem
8.
JACC Case Rep ; 2(11): 1734-1735, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33000000

RESUMO

Limited arterial vascular access precluded necessary transcatheter intervention in a 22-year-old woman with repaired interrupted aortic arch type B. Alternative transcaval vascular access enabled percutaneous therapy. This practice evolution is likely to benefit the growing numbers of adults with congenital heart disease. (Level of Difficulty: Advanced.).

9.
Pediatr Transplant ; 22(8): e13290, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30251298

RESUMO

BACKGROUND: Listed pediatric heart transplant patients have the highest solid-organ waitlist mortality rate. The donor-recipient body weight (DRBW) ratio is the clinical standard for allograft size matching but may unnecessarily limit a patient's donor pool. To overcome DRBW ratio limitations, two methods of performing virtual heart transplant fit assessments were developed that account for patient-specific nuances. Method 1 uses an allograft total cardiac volume (TCV) prediction model informed by patient data wherein a matched allograft 3-D reconstruction is selected from a virtual library for assessment. Method 2 uses donor images for a direct virtual transplant assessment. METHODS: Assessments were performed in medical image reconstruction software. The allograft model was developed using allometric/isometric scaling assumptions and cross-validation. RESULTS: The final predictive model included gender, height, and weight. The 25th-, 50th-, and 75th-percentiles for TCV percentage errors were -13% (over-prediction), -1%, and 8% (under-prediction), respectively. Two examples illustrating the potential of virtual assessments are presented. CONCLUSION: Transplant centers can apply these methods to perform their virtual assessments using existing technology. These techniques have potential to improve organ allocation. With additional experience and refinement, virtual transplants may become standard of care for determining suitability of donor organ size for an identified recipient.


Assuntos
Transplante de Coração/métodos , Coração/anatomia & histologia , Tamanho do Órgão , Obtenção de Tecidos e Órgãos/métodos , Adolescente , Adulto , Aloenxertos , Volume Cardíaco , Criança , Pré-Escolar , Diagnóstico por Imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Lactente , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Doadores de Tecidos , Tomografia Computadorizada por Raios X , Listas de Espera , Adulto Jovem
10.
World Neurosurg ; 88: 175-181, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26805698

RESUMO

BACKGROUND: Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. OBJECTIVE: The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. METHODS: A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. RESULTS: Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. CONCLUSIONS: The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation.


Assuntos
Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/cirurgia , Modelos Anatômicos , Neurocirurgia/educação , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Humanos , Silicones/química , Procedimentos Cirúrgicos Vasculares/métodos
11.
World Neurosurg ; 84(5): 1333-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26100167

RESUMO

BACKGROUND: Educational simulators provide a means for students and experts to learn and refine surgical skills. Educators can leverage the strengths of medical simulators to effectively teach complex and high-risk surgical procedures, such as placement of an external ventricular drain. OBJECTIVE: Our objective was to develop a cost-effective, patient-derived medical simulacrum for cerebral lateral ventriculostomy. METHODS: A cost-effective, patient-derived medical simulacrum was developed for placement of an external lateral ventriculostomy. Elastomeric and gel casting techniques were used to achieve realistic brain geometry and material properties. 3D printing technology was leveraged to develop accurate cranial properties and dimensions. An economical, gravity-driven pump was developed to provide normal and abnormal ventricular pressures. A small pilot study was performed to gauge simulation efficacy using a technology acceptance model. RESULTS: An accurate geometric representation of the brain was developed with independent lateral cerebral ventricular chambers. A gravity-driven pump pressurized the ventricular cavities to physiologic values. A qualitative study illustrated that the simulation has potential as an educational tool to train medical professionals in the ventriculostomy procedure. CONCLUSION: The ventricular simulacrum can improve learning in a medical education environment. Rapid prototyping and multi-material casting techniques can produce patient-derived models for cost-effective and realistic surgical training scenarios.


Assuntos
Ventrículos Cerebrais/anatomia & histologia , Modelos Anatômicos , Impressão Tridimensional , Ventriculostomia/métodos , Atitude do Pessoal de Saúde , Humanos , Hidrogéis , Ventrículos Laterais/anatomia & histologia , Imageamento por Ressonância Magnética , Neurocirurgia/educação , Projetos Piloto , Estudantes de Medicina , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...