Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Neuroradiol ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652163

RESUMO

PURPOSE: The high efficacy of flow diverters (FD) in the case of wide-neck aneurysms is well demonstrated, yet new challenges have arisen because of reported posttreatment failures and the growing number of new generation of devices. Our aim is to present a measurement-supported in silico workflow that automates the virtual deployment and subsequent hemodynamic analysis of FDs. In this work, the objective is to analyze the effects of FD deployment variability of two manufacturers on posttreatment flow reduction. METHODS: The virtual deployment procedure is based on detailed mechanical calibration of the flow diverters, while the flow representation is based on hydrodynamic resistance (HR) measurements. Computational fluid dynamic simulations resulted in 5 untreated and 80 virtually treated scenarios, including 2 FD designs in nominal and oversized deployment states. The simulated aneurysmal velocity reduction (AMVR) is correlated with the HR values and deployment scenarios. RESULTS: The linear HR coefficient and AMVR revealed a power-law relationship considering all 80 deployments. In nominal deployment scenarios, a significantly larger average AMVR was obtained (60.3%) for the 64-wire FDs than for 48-wire FDs (51.9%). In oversized deployments, the average AMVR was almost the same for 64-wire and 48-wire device types, 27.5% and 25.7%, respectively. CONCLUSION: The applicability of our numerical workflow was demonstrated, also in large-scale hemodynamic investigations. The study revealed a robust power-law relationship between a HR coefficient and AMVR. Furthermore, the 64 wire configurations in nominal sizing produced a significantly higher posttreatment flow reduction, replicating the results of other in vitro studies.

2.
Ultrason Sonochem ; 99: 106546, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37574642

RESUMO

A fixed-point iteration technique is presented to handle the implicit nature of the governing equations of nonlinear surface mode oscillations of acoustically excited microbubbles. The model is adopted from the theoretical work of Shaw [1], where the dynamics of the mean bubble radius and the surface modes are bi-directionally coupled via nonlinear terms. The model comprises a set of second-order ordinary differential equations. It extends the classic Keller-Miksis equation and the linearized dynamical equations for each surface mode. Only the implicit parts (containing the second derivatives) are reevaluated during the iteration process. The performance of the technique is tested at various parameter combinations. The majority of the test cases needs only a single reevaluation to achieve 10-9 error. Although the arithmetic operation count is higher than the Gauss elimination, due to its memory-friendly matrix-free nature, it is a viable alternative for high-performance GPU computations of massive parameter studies.

3.
Artigo em Inglês | MEDLINE | ID: mdl-37231591

RESUMO

Intracranial aneurysms are nowadays treated with endovascular flow diverter devices to avoid sac rupture. This study explores how different linear and quadratic hydrodynamic resistance parameters reduce the flow in the sac for five patient-specific sidewall aneurysms.The 125 performed blood flow simulations included the stents using a Darcy-Forcheimer porous layer approach based on real-life stent characteristics. Time- and space-averaged velocity magnitudes were strongly affected by the linear coefficient with a power-law relationship. Quadratic coefficients alter the flow in a minor way due to the low-velocity levels in the aneurysm sac and neck region.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...