Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc Inst Mech Eng H ; 232(1): 67-79, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29168434

RESUMO

Changes in knee shape and geometry resulting from total knee arthroplasty can affect patients in numerous important ways: pain, function, stability, range of motion, and kinematics. Quantitative data concerning these changes have not been previously available, to our knowledge, yet are essential to understand individual experiences of total knee arthroplasty and thereby improve outcomes for all patients. The limiting factor has been the challenge of accurately measuring these changes. Our study objective was to develop a conceptual framework and analysis method to investigate changes in knee shape and geometry, and prospectively apply it to a sample total knee arthroplasty population. Using clinically available computed tomography and radiography imaging systems, the three-dimensional knee shape and geometry of nine patients (eight varus and one valgus) were compared before and after total knee arthroplasty. All patients had largely good outcomes after their total knee arthroplasty. Knee shape changed both visually and numerically. On average, the distal condyles were slightly higher medially and lower laterally (range: +4.5 mm to -4.4 mm), the posterior condyles extended farther out medially but not laterally (range: +1.8 to -6.4 mm), patellofemoral distance increased throughout flexion by 1.8-3.5 mm, and patellar thickness alone increased by 2.9 mm (range: 0.7-5.2 mm). External femoral rotation differed preop and postop. Joint line distance, taking cartilage into account, changed by +0.7 to -1.5 mm on average throughout flexion. Important differences in shape and geometry were seen between pre-total knee arthroplasty and post-total knee arthroplasty knees. While this is qualitatively known, this is the first study to report it quantitatively, an important precursor to identifying the reasons for the poor outcome of some patients. Using the developed protocol and visualization techniques to compare patients with good versus poor clinical outcomes could lead to changes in implant design, implant selection, component positioning, and surgical technique. Recommendations based on this sample population are provided. Intraoperative and postoperative feedback could ultimately improve patient satisfaction.


Assuntos
Artroplastia do Joelho/efeitos adversos , Joelho/anatomia & histologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Joelho/diagnóstico por imagem , Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
2.
Proc Inst Mech Eng H ; 230(4): 265-78, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26936959

RESUMO

Total knee arthroplasty (TKA) changes the knee joint in both intentional and unintentional, known and unknown, ways. Patellofemoral and tibiofemoral kinematics play an important role in postoperative pain, function, satisfaction and revision, yet are largely unknown. Preoperative kinematics, postoperative kinematics or changes in kinematics may help identify causes of poor clinical outcome. Patellofemoral kinematics are challenging to record since the patella is obscured by the metal femoral component in X-ray and moves under the skin. The purpose of this study was to determine the kinematic degrees of freedom having significant changes and to evaluate the variability in individual changes to allow future study of patients with poor clinical outcomes. We prospectively studied the 6 degrees of freedom patellofemoral and tibiofemoral weightbearing kinematics, tibiofemoral contact points and helical axes of rotation of nine subjects before and at least 1 year after total knee arthroplasty using clinically available computed tomography and radiographic imaging systems. Normal kinematics for healthy individuals were identified from the literature. Significant differences existed between pre-TKA and post-TKA kinematics, with the post-TKA kinematics being closer to normal. While on average the pre-total knee arthroplasty knees in this group displayed no pivoting (only translation), individually only five knees displayed this behaviour (of these, two showed lateral pivoting, one showed medial pivoting and one showed central pivoting). There was considerable variability postoperatively as well (five central, two lateral and two medial pivoting). Both preop and postop, flexion behaviour was more hinge-like medially and more rolling laterally. Helical axes were more consistent postop for this group. An inclusive understanding of the pre-TKA and post-TKA kinematics and changes in kinematics due to total knee arthroplasty could improve implant design, patient diagnosis and surgical technique.


Assuntos
Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos/fisiologia , Articulação do Joelho/fisiopatologia , Ossos da Perna/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Articulação do Joelho/cirurgia , Ossos da Perna/cirurgia , Masculino , Pessoa de Meia-Idade
3.
Clin Biomech (Bristol, Avon) ; 28(1): 55-60, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23157843

RESUMO

BACKGROUND: Different suspension systems that are used within prosthetic devices may alter the distribution of pressure inside the prosthetic socket in lower limb amputees. This study aimed to compare the interface pressure of a new magnetic suspension system with the pin/lock and Seal-In suspension systems. METHODS: Twelve unilateral transtibial amputees participated in the study. The subjects walked on a level walkway at a self-selected speed. The resultant peak pressure with the three different suspension systems was recorded using F-socket transducers. FINDINGS: There were significant statistical differences between the three studied suspension systems. Pair-wise analyses revealed that the mean peak pressure (kPa) was lower with the magnetic system than it was with the pin/lock system over the anterior and posterior aspects during one gait cycle (89.89 vs. 79.26 and 47.22 vs. 26.01, respectively). Overall, the average peak pressure values were higher with the Seal-In system than they were with the new magnetic lock and pin/lock system. INTERPRETATION: The new magnetic system might reduce the pressure within the prosthetic socket in comparison to the pin/lock and Seal-In system during one gait cycle. This is particularly important during the swing phase of gait and may reduce the pain and discomfort at the distal residual limb in comparison to the pin/lock system.


Assuntos
Amputados/reabilitação , Membros Artificiais , Marcha , Ajuste de Prótese/instrumentação , Cotos de Amputação , Análise de Variância , Calibragem , Feminino , Humanos , Perna (Membro) , Masculino , Pessoa de Meia-Idade , Pressão , Desenho de Prótese , Ajuste de Prótese/métodos , Caminhada
4.
J Rehabil Res Dev ; 49(9): 1321-30, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23408214

RESUMO

Poor suspension increases slippage of the residual limb inside the socket during ambulation. The main purpose of this article is to evaluate the pistoning at the prosthetic liner-socket interface during gait and assess patients' satisfaction with two different liners. Two prostheses with seal-in and locking liners were fabricated for each of the 10 subjects with transtibial amputation. The Vicon motion system was used to measure the pistoning during gait. The subjects were also asked to complete a Prosthesis Evaluation Questionnaire. The results revealed higher pistoning inside the socket during gait with the locking liner than with the seal-in liner (p < 0.05). The overall satisfaction with the locking liner was higher (p < 0.05) because of the relative ease with which the patients could don and doff the device. As such, pistoning may not be the main factor that determines patients' overall satisfaction with the prosthesis and other factors may also contribute to comfort and satisfaction with prostheses. The article also verifies the feasibility of the Vicon motion system for measuring pistoning during gait.


Assuntos
Membros Artificiais , Marcha , Satisfação do Paciente , Desenho de Prótese , Adulto , Idoso , Cotos de Amputação , Humanos , Perna (Membro) , Pessoa de Meia-Idade , Estresse Mecânico , Inquéritos e Questionários , Tíbia , Caminhada , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...