Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Radiol ; 122: 108703, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31810641

RESUMO

PURPOSE: To determine the effect of tube load, model-based iterative reconstruction (MBIR) strength and slice thickness in abdominal CT using visual comparison of multi-planar reconstruction images. METHOD: Five image criteria were assessed independently by four radiologists on two data sets at 42- and 98-mAs tube loads for 25 patients examined on a 192-slice dual-source CT scanner. Effect of tube load, MBIR strength, slice thickness and potential dose reduction was estimated with Visual Grading Regression (VGR). Objective image quality was determined by measuring noise (SD), contrast-to-noise (CNR) ratio and noise-power spectra (NPS). RESULTS: Comparing 42- and 98-mAs tube loads, improved image quality was observed as a strong effect of log tube load regardless of MBIR strength (p < 0.001). Comparing strength 5 to 3, better image quality was obtained for two criteria (p < 0.01), but inferior for liver parenchyma and overall image quality. Image quality was significantly better for slice thicknesses of 2mm and 3mm compared to 1mm, with potential dose reductions between 24%-41%. As expected, with decrease in slice thickness and algorithm strength, the noise power and SD (HU-values) increased, while the CNR decreased. CONCLUSION: Increasing slice thickness from 1 mm to 2 mm or 3 mm allows for a possible dose reduction. MBIR strength 5 shows improved image quality for three out of five criteria for 1 mm slice thickness. Increasing MBIR strength from 3 to 5 has diverse effects on image quality. Our findings do not support a general recommendation to replace strength 3 by strength 5 in clinical abdominal CT protocols. However, strength 5 may be used in task-based protocols.


Assuntos
Abdome/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Cintilografia , Tomógrafos Computadorizados
2.
BMC Med Imaging ; 19(1): 64, 2019 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-31399078

RESUMO

BACKGROUND: Our aim was to compare CT images from native, nephrographic and excretory phases using image quality criteria as well as the detection of positive pathological findings in CT Urography, to explore if the radiation burden to the younger group of patients or patients with negative outcomes can be reduced. METHODS: This is a retrospective study of 40 patients who underwent a CT Urography examination on a 192-slice dual source scanner. Image quality was assessed for four specific renal image criteria from the European guidelines, together with pathological assessment in three categories: renal, other abdominal, and incidental findings without clinical significance. Each phase was assessed individually by three radiologists with varying experience using a graded scale. Certainty scores were derived based on the graded assessments. Statistical analysis was performed using visual grading regression (VGR). The limit for significance was set at p = 0.05. RESULTS: For visual reproduction of the renal parenchyma and renal arteries, the image quality was judged better for the nephrogram phase (p < 0.001), whereas renal pelvis/calyces and proximal ureters were better reproduced in the excretory phase compared to the native phase (p < 0.001). Similarly, significantly higher certainty scores were obtained in the nephrogram phase for renal parenchyma and renal arteries, but in the excretory phase for renal pelvis/calyxes and proximal ureters. Assessment of pathology in the three categories showed no statistically significant differences between the three phases. Certainty scores for assessment of pathology, however, showed a significantly higher certainty for renal pathology when comparing the native phase to nephrogram and excretory phase and a significantly higher score for nephrographic phase but only for incidental findings. CONCLUSION: Visualisation of renal anatomy was as expected with each post-contrast phase showing favourable scores compared to the native phase. No statistically significant differences in the assessment of pathology were found between the three phases. The low-dose CT (LDCT) seems to be sufficient in differentiating between normal and pathological examinations. To reduce the radiation burden in certain patient groups, the LDCT could be considered a suitable alternative as a first line imaging method. However, radiologists should be aware of its limitations.


Assuntos
Rim/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Artéria Renal/diagnóstico por imagem , Urografia/instrumentação , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Rim/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Tecido Parenquimatoso/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/instrumentação
3.
Eur Radiol ; 28(6): 2464-2473, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29368163

RESUMO

PURPOSE: To estimate potential dose reduction in abdominal CT by visually comparing images reconstructed with filtered back projection (FBP) and strengths of 3 and 5 of a specific MBIR. MATERIAL AND METHODS: A dual-source scanner was used to obtain three data sets each for 50 recruited patients with 30, 70 and 100% tube loads (mean CTDIvol 1.9, 3.4 and 6.2 mGy). Six image criteria were assessed independently by five radiologists. Potential dose reduction was estimated with Visual Grading Regression (VGR). RESULTS: Comparing 30 and 70% tube load, improved image quality was observed as a significant strong effect of log tube load and reconstruction method with potential dose reduction relative to FBP of 22-47% for MBIR strength 3 (p < 0.001). For MBIR strength 5 no dose reduction was possible for image criteria 1 (liver parenchyma), but dose reduction between 34 and 74% was achieved for other criteria. Interobserver reliability showed agreement of 71-76% (κw 0.201-0.286) and intra-observer reliability of 82-96% (κw 0.525-0.783). CONCLUSION: MBIR showed improved image quality compared to FBP with positive correlation between MBIR strength and increasing potential dose reduction for all but one image criterion. KEY POINTS: • MBIR's main advantage is its de-noising properties, which facilitates dose reduction. • MBIR allows for potential dose reduction in relation to FBP. • Visual Grading Regression (VGR) produces direct numerical estimates of potential dose reduction. • MBIR strengths 3 and 5 dose reductions were 22-34 and 34-74%. • MBIR strength 5 demonstrates inferior performance for liver parenchyma.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Radiografia Abdominal/normas , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/normas , Adulto Jovem
4.
Eur Radiol ; 20(3): 714-24, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19727748

RESUMO

OBJECTIVE: A prerequisite for successful clinical use of functional magnetic resonance imaging (fMRI) is the selection of an appropriate imaging sequence. The aim of this study was to compare 2D and 3D fMRI sequences using different image quality assessment methods. METHODS: Descriptive image measures, such as activation volume and temporal signal-to-noise ratio (TSNR), were compared with results from visual grading characteristics (VGC) analysis of the fMRI results. RESULTS: Significant differences in activation volume and TSNR were not directly reflected by differences in VGC scores. The results suggest that better performance on descriptive image measures is not always an indicator of improved diagnostic quality of the fMRI results. CONCLUSION: In addition to descriptive image measures, it is important to include measures of diagnostic quality when comparing different fMRI data acquisition methods.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...