Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
ESC Heart Fail ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38725133

RESUMO

AIMS: It is unclear whether activated partial thromboplastin time (aPTT) or anti-Xa is more accurate for monitoring heparin anticoagulation in mechanical circulatory support (MCS) patients. This study investigates the relationship between aPTT and anti-Xa in MCS patients and identifies predictors of discordance. METHODS AND RESULTS: aPTT and anti-Xa were simultaneously measured in a prospective cohort of MCS patients receiving unfractionated heparin at a tertiary academic medical centre. Therapeutic aPTT and anti-Xa levels were 60-100 s and 0.3-0.7 IU/mL, respectively, and concordance was defined as both levels being subtherapeutic, therapeutic, or supratherapeutic. To identify predictors of discordance, both a machine learning random forest model and a multivariate regression model were applied to patient demographics, device type, and 14 laboratory variables; 23 001 pairs of simultaneously measured aPTT/anti-Xa were collected from 699 MCS patients. aPTT and anti-Xa were concordant in 35.5% of paired observations and discordant in 64.5% (aPTT > antiXa 61.5%; aPTT < antiXa 3.0%). Discordance with a high aPTT relative to anti-Xa (aPTT > antiXa) was associated with high INR, eGFR, and total bilirubin, as well as low platelets, haemoglobin, pre-albumin, white blood cell count, and haptoglobin. Total artificial heart and durable ventricular assist devices were more likely to be associated with aPTT > anti-Xa than temporary MCS devices. CONCLUSIONS: aPTT and anti-Xa were frequently discordant in MCS patients receiving heparin anticoagulation. Clinical conditions common in MCS patients such as concurrent warfarin use, malnutrition, haemolysis, and thrombocytopenia, as well as durable type of MCS devices were associated with a high aPTT relative to anti-Xa.

2.
Clin Neuropathol ; 43(2): 53-59, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38517059

RESUMO

Primary T-cell lymphoma (TCL) of the central nervous system (CNS) is a rare and potentially aggressive entity. We describe a case of TCL presenting in the basal ganglia with γδ receptor expression and a remarkably aggressive clinical course. To the best of our knowledge, this is the fifth reported case of γδ TCL presenting in the CNS. We review existing literature, including the previously reported cases of γδ TCL of the CNS. In our case, a 69-year-old male presented with acute onset dysarthria and right-sided weakness, with initial imaging concerning for stroke. Repeat imaging demonstrated a 2.6-cm mass in the left basal ganglia-corona radiata. Pathologic examination of a stereotactic biopsy revealed TCL with γδ receptor phenotype. The patient suffered rapid clinical decline and passed away within 6 weeks of initial diagnosis. This represents an important differential diagnosis and sheds light on the potentially poor prognosis conferred by γδ TCL of the CNS.


Assuntos
Linfoma de Células T , Linfócitos T , Masculino , Humanos , Idoso , Linfócitos T/patologia , Receptores de Antígenos de Linfócitos T gama-delta/genética , Receptores de Antígenos de Linfócitos T gama-delta/metabolismo , Linfoma de Células T/diagnóstico , Linfoma de Células T/patologia , Sistema Nervoso Central/patologia , Biópsia
3.
Transfusion ; 64(3): 449-453, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38299721

RESUMO

BACKGROUND: Administering platelets through a rapid infuser is proven to be safe. However, the clinical significance of infusing ABO-incompatible platelets with red blood cells (RBCs) in a rapid infuser remains unclear. There is a theoretical risk that isoagglutinin in the plasma of a platelet unit can interact with RBCs and induce hemolysis. MATERIALS AND METHODS: Seven in vitro studies were performed including five cases (type A RBCs and type O platelets) and two controls (type A RBCs and platelets). Anti-A titers were measured in platelet units. An RBC unit and a platelet unit were mixed in the rapid infuser reservoir and incubated for 30 min. The primary outcome was the presence of hemolysis based on the following parameters: free hemoglobin concentration, hemolysis check, direct antiglobulin test (DAT), and direct agglutination. RESULTS: The post-mix DAT was positive for IgG in all test samples (5/5), and weakly positive for complement in 3/5. The changes in free Hb in test cases between measured and calculated post-mix spanned -2.2 to +3.4 mg/dL. Post-mix hemolysis check was negative in 3/5 and slightly positive in 2/5 cases, with no significant differences compared to the control case. Anti-A titers ranged from 16 to 512 and were not associated with hemolysis. All samples were negative for direct agglutination. CONCLUSION: Our study suggested that mixing ABO-incompatible platelets with RBCs in a rapid infuser does not induce in vitro hemolysis. These findings support the use of rapid infusers regardless of platelet compatibility in support of hemostatic resuscitation.


Assuntos
Sistema ABO de Grupos Sanguíneos , Hemólise , Humanos , Transfusão de Plaquetas/efeitos adversos , Incompatibilidade de Grupos Sanguíneos , Plaquetas , Anticorpos
4.
Int J Lab Hematol ; 45 Suppl 2: 71-78, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37211360

RESUMO

Hemoglobin disorders are among the most common genetic diseases worldwide. Molecular diagnosis is helpful in cases where the diagnosis is uncertain and for genetic counseling. Protein-based diagnostic techniques are frequently adequate for initial diagnosis. Molecular genetic testing is pursued in some cases, particularly when a definitive diagnosis is not possible and especially for the purpose of assessing genetic risk for couples wanting to have children. The expertise available in the clinical hematology laboratory is essential for the diagnosis of patients with hemoglobin abnormalities. Initial diagnoses are made using protein-based techniques such as electrophoresis and chromatography. Based on these findings, genetic risk to an individual's offspring can be assessed. In the setting of ß-thalassemia and other ß-globin disorders, coincident α-thalassemia may be difficult to diagnose, which can have potentially serious consequences. In addition, unusual forms of ß-thalassemia caused by deletions in the ß-globin locus cannot be definitively characterized using standard techniques. Molecular diagnostic testing has an important role in the diagnosis of hemoglobin disorders and is important in the setting of genetic counseling. Molecular testing also has a role in prenatal diagnosis to identify fetuses affected by severe hemoglobinopathies and thalassemias.


Assuntos
Hemoglobinopatias , Talassemia alfa , Talassemia beta , Gravidez , Feminino , Criança , Humanos , Talassemia beta/diagnóstico , Talassemia beta/genética , Hemoglobinopatias/diagnóstico , Hemoglobinopatias/genética , Talassemia alfa/genética , Diagnóstico Pré-Natal/métodos , Técnicas de Diagnóstico Molecular , Globinas beta/genética
5.
Am J Clin Pathol ; 158(2): 270-276, 2022 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-35460401

RESUMO

OBJECTIVES: The US Food and Drug Administration (FDA)-approved CELLSEARCH assay (Menarini Silicon Biosystems) for circulating tumor cells (CTCs) relies on expression of an epithelial cell adhesion molecule to enrich for CTCs. We sought to validate a CTC assay (RareCyte) for clinical use that instead collects a buffy coat preparation enriched for CTCs. METHODS: Normal peripheral blood specimens spiked with cultured breast and prostate cancer cells and 47 clinical samples were used to validate assay performance. Specimens were enriched for buffy coat cells and applied onto 8 glass slides. The slides were immunofluorescently stained and imaged by automated microscopy and computer-aided image analysis. RESULTS: The assay was 100% specific for detecting spiked tumor cells. For samples spiked with 25, 50, and 125 cells, the percentage coefficients of variation were 42%, 21%, and 3.7%, respectively. Linearity studies demonstrated a slope of 0.99, an intercept of 1.6, and R2 of 0.96. Recoveries at the 25-, 50-, and 125-cell levels were 92%, 111%, and 100%, respectively. Clinical samples run on both CELLSEARCH and RareCyte correlated with an R2 of 0.8 after log-transformation and demonstrated 87.5% concordance using the CELLSEARCH criteria for predicting adverse outcomes. CONCLUSIONS: The RareCyte CTC assay has comparable performance to the FDA-cleared method and is ready for further clinical validation studies.


Assuntos
Células Neoplásicas Circulantes , Neoplasias da Próstata , Biomarcadores Tumorais/metabolismo , Contagem de Células , Centrifugação , Humanos , Masculino , Microscopia de Fluorescência , Células Neoplásicas Circulantes/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia
6.
Nat Commun ; 13(1): 831, 2022 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-35149711

RESUMO

Frequent prothrombin time (PT) and international normalized ratio (INR) testing is critical for millions of people on lifelong anticoagulation with warfarin. Currently, testing is performed in hospital laboratories or with expensive point-of-care devices limiting the ability to test frequently and affordably. We report a proof-of-concept PT/INR testing system that uses the vibration motor and camera on smartphones to track micro-mechanical movements of a copper particle. The smartphone system computed the PT/INR with inter-class correlation coefficients of 0.963 and 0.966, compared to a clinical-grade coagulation analyzer for 140 plasma samples and demonstrated similar results for 80 whole blood samples using a single drop of blood (10 µl). When tested with 79 blood samples with coagulopathic conditions, the smartphone system demonstrated a correlation of 0.974 for both PT/INR. Given the ubiquity of smartphones in the global setting, this proof-of-concept technology may provide affordable and effective PT and INR testing in low-resource environments.


Assuntos
Testes de Coagulação Sanguínea/métodos , Coeficiente Internacional Normatizado/métodos , Tempo de Protrombina/métodos , Smartphone , Trombose/diagnóstico , Algoritmos , Anticoagulantes/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Testes de Coagulação Sanguínea/instrumentação , Hemorragia , Humanos , Coeficiente Internacional Normatizado/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Tempo de Protrombina/instrumentação , Varfarina/farmacologia
7.
Am J Clin Pathol ; 156(2): 185-197, 2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-34151348

RESUMO

OBJECTIVES: We compared complete blood count (CBC) with differential and markers of inflammation and coagulation in patients with and without coronavirus disease 2019 (COVID-19) presenting to emergency departments in Seattle, WA. METHODS: We reviewed laboratory values for 1 week following each COVID-19 test for adult patients who received a standard severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcription polymerase chain reaction (RT-PCR) test before April 13, 2020. Results were compared by COVID-19 status and clinical course. RESULTS: In total 1,027 patients met inclusion criteria. Patients with COVID-19 (n = 155) had lower leukocytes (P < .0001), lymphocytes (P < .0001), platelets (P < .0001), and higher hemoglobin (P = .0140) than those without, but absolute differences were small. Serum albumin was lower in patients with COVID-19 (P < .0001) and serum albumin, neutrophil to lymphocyte ratio (NLR), and red cell distribution width (RDW) were each associated with disease severity. NLR did not differ between patients with COVID-19 and those without (P = .8012). CONCLUSIONS: Patients with COVID-19 had modestly lower leukocyte, lymphocyte, and platelet counts and higher hemoglobin values than patients without COVID-19. The NLR, serum albumin, and RDW varied with disease severity, regardless of COVID-19 status.


Assuntos
Contagem de Células Sanguíneas , Coagulação Sanguínea , COVID-19/sangue , Inflamação/sangue , Linfócitos/citologia , Adulto , Biomarcadores/sangue , Contagem de Células Sanguíneas/métodos , COVID-19/diagnóstico , Serviço Hospitalar de Emergência , Humanos , Contagem de Leucócitos/métodos , Contagem de Linfócitos/métodos , Masculino , Pessoa de Meia-Idade , Neutrófilos/citologia , Contagem de Plaquetas/métodos , SARS-CoV-2/patogenicidade
8.
Blood ; 137(8): 1082-1089, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-32898858

RESUMO

Heparin-induced thrombocytopenia (HIT) is a life-threatening, prothrombotic, antibody-mediated disorder. To maximize the likelihood of recovery, early and accurate diagnosis is critical. Widely available HIT assays, such as the platelet factor 4 (PF4) heparin enzyme-linked immunosorbent assay (ELISA) lack specificity, and the gold-standard carbon 14-labeled serotonin release assay (SRA) is of limited value for early patient management because it is available only through reference laboratories. Recent studies have demonstrated that pathogenic HIT antibodies selectively activate PF4-treated platelets and that a technically simpler assay, the PF4-dependent P-selectin expression assay (PEA), may provide an option for rapid and conclusive results. Based upon predefined criteria that combined 4Ts scores and HIT ELISA results, 409 consecutive adults suspected of having HIT were classified as disease positive, negative, or indeterminate. Patients deemed HIT indeterminate were considered disease negative in the primary analysis and disease positive in a sensitivity analysis. The ability of PEA and SRA to identify patients judged to have HIT was compared using receiver operating characteristic curve statistics. Using these predefined criteria, the diagnostic accuracy of PEA was high (area under the curve [AUC], 0.94; 95% confidence interval [CI], 0.87-1.0) and similar to that of SRA (AUC, 0.91; 95% CI, 0.82-1.0). In sensitivity analysis, the AUCs of PEA and SRA were also similar at 0.88 (95% CI, 0.78-0.98) and 0.86 (95% CI, 0.77-0.96), respectively. The PEA, a technically simple nonradioactive assay that uses ∼20-fold fewer platelets compared with the SRA, had high accuracy for diagnosing HIT. Widespread use of the PEA may facilitate timely and more effective management of patients with suspected HIT.


Assuntos
Anticoagulantes/efeitos adversos , Heparina/efeitos adversos , Fator Plaquetário 4/imunologia , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Adulto , Idoso , Anticorpos/imunologia , Anticoagulantes/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Heparina/imunologia , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Selectina-P/imunologia , Estudos Prospectivos , Trombocitopenia/imunologia
9.
Clin Transl Sci ; 13(4): 718-726, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32004415

RESUMO

Warfarin is a narrow therapeutic index anticoagulant drug and its use is associated with infrequent but significant adverse bleeding events. The international normalized ratio (INR) is the most commonly used biomarker to monitor and titrate warfarin therapy. However, INR is derived from a functional assay, which determines clotting efficiency at the time of measurement and is susceptible to technical variability. Protein induced by vitamin K antagonist-II (PIVKA-II) has been suggested as a biomarker of long-term vitamin K status, providing mechanistic insights about variation in the functional assay. However, the currently available antibody-based PIVKA-II assay does not inform on the position and number of des-carboxylation sites in prothrombin. The assay presented in this paper provides simultaneous quantification of carboxy and des-carboxy prothrombin that are essential for monitoring early changes in INR and, thus, serves as the superior tool for managing warfarin therapy. Additionally, this assay permits the quantification of total prothrombin level, which is affected by warfarin treatment. Prothrombin recovery from plasma was 95% and the liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was linear (r2  = 0.98) with a dynamic range of 1-100 µg/mL. The assay interday precision was within 20%. A des-carboxy peptide of prothrombin (GNLER) was negatively correlated with active prothrombin (Pearson r = 0.99, P < 0.0001), whereas its association was positively linked with INR values (Pearson r = 0.75, P < 0.015). This novel LC-MS/MS assay for active and inactive prothrombin quantification can be applied to titrate anticoagulant therapy and to monitor the impact of diseases, such as hepatocellular carcinoma on clotting physiology.


Assuntos
Anticoagulantes/efeitos adversos , Hemorragia/prevenção & controle , Protrombina/análise , Varfarina/efeitos adversos , Anticoagulantes/administração & dosagem , Biomarcadores/sangue , Biomarcadores/química , Coagulação Sanguínea/efeitos dos fármacos , Coagulação Sanguínea/fisiologia , Carcinoma Hepatocelular/sangue , Carcinoma Hepatocelular/fisiopatologia , Estudos de Casos e Controles , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Voluntários Saudáveis , Hemorragia/sangue , Hemorragia/induzido quimicamente , Hemorragia/diagnóstico , Humanos , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/fisiopatologia , Protrombina/química , Espectrometria de Massas em Tandem/métodos , Varfarina/administração & dosagem
10.
J Appl Lab Med ; 3(5): 870-882, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-31639762

RESUMO

BACKGROUND: Venous thromboembolism (VTE) is the third most common cause of cardiovascular illness and is projected to double in incidence by 2050. It is a spectrum of disease that includes deep venous thrombosis (DVT) and pulmonary embolism (PE). In February 2016, the American College of Chest Physicians provided updated management guidelines for DVT and PE to address some of the unresolved questions from the previous version and to provide recommendations related to newer anticoagulants. CONTENT: Here we review current concepts for screening, diagnosis, thromboprophylaxis, and management of DVT and PE. We also describe the management of VTE in acute, long-term, and extended phases of treatment. Thrombophilia testing is rarely necessary and should be used judiciously; the laboratory can serve an important role in preventing unnecessary testing. The direct oral anticoagulants are as effective as conventional treatment and are preferred agents except in the case of cancer. The initial management of PE should be based on risk stratification including the use of D-dimer testing. Thrombolysis is used in cases of hemodynamically unstable PE and not for low-risk patients who can be treated on an outpatient basis. SUMMARY: This review is intended to provide readers with updated guidelines for screening, testing, prophylaxis, and management from various organizations.


Assuntos
Anticoagulantes/uso terapêutico , Técnicas de Laboratório Clínico/métodos , Técnicas e Procedimentos Diagnósticos/tendências , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/tratamento farmacológico , Gerenciamento Clínico , Humanos
11.
J Thromb Thrombolysis ; 47(3): 403-408, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30600427

RESUMO

There are no clear and consistent guidelines on how to utilize DOAC assays, and reports on the use of DOAC levels in clinical practice is limited. The objective of this study was to analyze why DOAC levels are ordered, how the results affect clinical decision-making, and to determine if DOAC assays are utilized appropriately. This was a retrospective chart review study analyzing 150 dabigatran, rivaroxaban, and apixaban levels performed at a single institution. The majority of DOAC assays were ordered in situations or special patient populations where confirming absence or detecting presence of drug may be useful. The most common indication for ordering assays was prior to an invasive procedure. Most DOAC levels were timed appropriately but peak levels were most likely to be incorrectly ordered. Clinical decisions following level results depended on indication for ordering and were most commonly used to determine whether or not to proceed with an invasive procedure. The results of our study suggest while DOAC assays are generally ordered for useful indications, there is still a lack of understanding of when levels should be drawn and how to interpret DOAC assay results.


Assuntos
Monitoramento de Medicamentos/métodos , Inibidores do Fator Xa/sangue , Padrões de Prática Médica/normas , Anticoagulantes/sangue , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico , Dabigatrana/sangue , Dabigatrana/farmacologia , Dabigatrana/uso terapêutico , Tomada de Decisões , Inibidores do Fator Xa/farmacologia , Inibidores do Fator Xa/uso terapêutico , Feminino , Humanos , Masculino , Pirazóis/sangue , Pirazóis/farmacologia , Pirazóis/uso terapêutico , Piridonas/sangue , Piridonas/farmacologia , Piridonas/uso terapêutico , Estudos Retrospectivos , Rivaroxabana/sangue , Rivaroxabana/farmacologia , Rivaroxabana/uso terapêutico , Procedimentos Cirúrgicos Operatórios/métodos
12.
J Mol Diagn ; 21(1): 16-18, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30268945

RESUMO

This commentary highlights the article by Kim et al that suggests use of two different next-generation sequencing-based assays for detection of fusion RNAs in patients with acute leukemia.


Assuntos
Neoplasias Hematológicas , RNA , Fusão Gênica , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Análise de Sequência de RNA , Translocação Genética
13.
Am J Clin Pathol ; 151(3): 302-305, 2019 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-30423028

RESUMO

Objectives: To compare the accuracy and reliability of phenotypic activated protein C resistance (aPC-R) assays with a genotypic assay for the factor V Leiden F5 p.R506Q (FVL) mutation. Methods: Data were obtained from an electronic data warehouse for FVL testing performed at an academic institution with a large referral laboratory service. In total, 1,596 patients were identified who had undergone both phenotypic aPC-R and genotypic FVL mutation testing. Results: Phenotypic testing showed a high level of sensitivity, specificity, and other biostatistical values compared with genotypic testing. Improvements in technology decreased the amount of equivocal phenotypic results. Conclusions: Phenotypic assays had close to total concordance with genotypic assays over 16 years of testing. Changing ordering practices could result in up to an 80% reduction in testing costs.


Assuntos
Resistência à Proteína C Ativada/genética , Fator V/genética , Resistência à Proteína C Ativada/diagnóstico , Resistência à Proteína C Ativada/patologia , Testes de Coagulação Sanguínea , Genótipo , Humanos , Mutação , Fenótipo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Artigo em Inglês | MEDLINE | ID: mdl-33282691

RESUMO

Burkitt lymphoma (BL) is a highly aggressive, B cell non-Hodgkin lymphoma (NHL) that is rare outside Africa. We report a case of HIV-associated BL originating in the right maxillary sinus in a 31-year-old Hispanic male living in Washington, USA. We also highlight the diagnostic challenges in arriving at the diagnosis when the patient initially presented with a painless right facial swelling. Rapid diagnosis and treatment are critical because BL is one of the fastest-growing tumors. Treatment involves brief duration of high intensity chemotherapy and central nervous system prophylaxis. It is important for oral and maxillofacial surgeons to recognize this disease and understand the necessary steps to treat this aggressive tumor.

15.
Fatigue ; 6(2): 80-91, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30112249

RESUMO

BACKGROUND: Chronic fatigue syndrome (CFS) is characterized by prolonged fatigue and other physical and neurocognitive symptoms. Some studies suggest that CFS is accompanied by disruptions in the number and function of various lymphocytes. However, it is not clear which lymphocytes might influence CFS symptoms. PURPOSE: To determine if patient reported fatigue symptoms and physical functioning scores significantly changed across time with lymphocyte counts as evidence of a relation among chronic fatigue symptoms and the immune response. METHODS: The current longitudinal, naturalistic study assessed the cellular expression of three lymphocyte subtypes -- natural killer (NK) cells (CD3-CD16+ and CD3-CD56+) and naïve T cells (CD4+CD45RA+) -- to determine whether changes in lymphocytes at 4 time points across 18 months were associated with clinical outcomes, including CFS symptoms, physical functioning, and vitality, among patients with chronic fatigue.. Latent growth curve models were used to examine the longitudinal relationship between lymphocytes and clinical outcomes. RESULTS: Ninety-three patients with Fukuda-based CFS and seven with non-CFS fatigue provided study data. Results indicated that higher proportions of naïve T cells and lower proportions of NK cells were associated with worse physical functioning, whereas higher proportions of NK cells (CD3-CD16+) and lower proportions of naïve T cells were associated with fewer CFS symptoms. CONCLUSION: These findings suggest that lymphocytes are modestly related to clinical outcomes over time.

16.
Am J Clin Pathol ; 148(1): 6-15, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28605432

RESUMO

OBJECTIVES: To describe the use of molecular diagnostic techniques for patients with hemoglobin disorders. METHODS: A clinical scenario is presented in which molecular diagnosis is important for genetic counseling. Globin disorders, techniques for their diagnosis, and the role of molecular genetic testing in managing patients with these disorders are described in detail. RESULTS: Hemoglobin disorders, including thalassemias and hemoglobinopathies, are among the commonest genetic diseases, and the clinical laboratory is essential for the diagnosis of patients with these abnormalities. Most disorders can be diagnosed with protein-based techniques such as electrophoresis and chromatography. Since severe syndromes can result due to inheritance of combinations of globin genetic disorders, genetic counseling is important to prevent adverse outcomes. Protein-based methods cannot always detect potentially serious thalassemia disorders; in particular, α-thalassemia may be masked in the presence of ß-thalassemia. Deletional forms of ß-thalassemia are also sometimes difficult to diagnose definitively with standard methods. CONCLUSIONS: Molecular genetic testing serves an important role in identifying individuals carrying thalassemia traits that can cause adverse outcomes in offspring. Furthermore, prenatal genetic testing can identify fetuses with severe globin phenotypes.


Assuntos
Hemoglobinopatias/diagnóstico , Técnicas de Diagnóstico Molecular , Talassemia/diagnóstico , Feminino , Testes Genéticos , Hemoglobinopatias/genética , Humanos , Masculino , Gravidez , Diagnóstico Pré-Natal , Talassemia/genética
19.
J Mol Diagn ; 18(1): 92-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26612711

RESUMO

Thalassemia is among the most common genetic diseases worldwide. α-Thalassemia is usually caused by deletion of one or more of the duplicated HBA genes on chromosome 16. In contrast, most ß-thalassemia results from point mutations that decrease or eliminate expression of the HBB gene on chromosome 11. Deletions within the HBB locus result in thalassemia or hereditary persistence of fetal Hb. Although routine diagnostic testing cannot distinguish thalassemia deletions from point mutations, deletional hereditary persistence of fetal Hb is notable for having an elevated HbF level with a normal mean corpuscular volume. A small number of deletions accounts for most α-thalassemias; in contrast, there are no predominant HBB deletions causing ß-thalassemia. To facilitate the identification and characterization of deletions of the HBA and HBB globin loci, we performed array-based comparative genomic hybridization using a custom oligonucleotide microarray. We accurately mapped the breakpoints of known and previously uncharacterized HBB deletions defining previously uncharacterized deletion breakpoints by PCR amplification and sequencing. The array also successfully identified the common HBA deletions --(SEA) and --(FIL). In summary, comparative genomic hybridization can be used to characterize deletions of the HBA and HBB loci, allowing high-resolution characterization of novel deletions that are not readily detected by PCR-based methods.


Assuntos
Deleção de Genes , Hemoglobina A/genética , Hemoglobinas/genética , Talassemia alfa/genética , Talassemia beta/genética , Adulto , Criança , Pré-Escolar , Hibridização Genômica Comparativa/métodos , Feminino , Humanos , Lactente , Masculino , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase , alfa-Globinas/genética , Talassemia alfa/diagnóstico , Globinas beta/genética , Talassemia beta/diagnóstico
20.
BMC Cancer ; 15: 360, 2015 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-25944336

RESUMO

BACKGROUND: Circulating tumor cells (CTCs) are malignant cells that have migrated from solid cancers into the blood, where they are typically present in rare numbers. There is great interest in using CTCs to monitor response to therapies, to identify clinically actionable biomarkers, and to provide a non-invasive window on the molecular state of a tumor. Here we characterize the performance of the AccuCyte®--CyteFinder® system, a comprehensive, reproducible and highly sensitive platform for collecting, identifying and retrieving individual CTCs from microscopic slides for molecular analysis after automated immunofluorescence staining for epithelial markers. METHODS: All experiments employed a density-based cell separation apparatus (AccuCyte) to separate nucleated cells from the blood and transfer them to microscopic slides. After staining, the slides were imaged using a digital scanning microscope (CyteFinder). Precisely counted model CTCs (mCTCs) from four cancer cell lines were spiked into whole blood to determine recovery rates. Individual mCTCs were removed from slides using a single-cell retrieval device (CytePicker™) for whole genome amplification and subsequent analysis by PCR and Sanger sequencing, whole exome sequencing, or array-based comparative genomic hybridization. Clinical CTCs were evaluated in blood samples from patients with different cancers in comparison with the CellSearch® system. RESULTS: AccuCyte--CyteFinder presented high-resolution images that allowed identification of mCTCs by morphologic and phenotypic features. Spike-in mCTC recoveries were between 90 and 91%. More than 80% of single-digit spike-in mCTCs were identified and even a single cell in 7.5 mL could be found. Analysis of single SKBR3 mCTCs identified presence of a known TP53 mutation by both PCR and whole exome sequencing, and confirmed the reported karyotype of this cell line. Patient sample CTC counts matched or exceeded CellSearch CTC counts in a small feasibility cohort. CONCLUSION: The AccuCyte--CyteFinder system is a comprehensive and sensitive platform for identification and characterization of CTCs that has been applied to the assessment of CTCs in cancer patient samples as well as the isolation of single cells for genomic analysis. It thus enables accurate non-invasive monitoring of CTCs and evolving cancer biology for personalized, molecularly-guided cancer treatment.


Assuntos
Separação Celular/métodos , Células Neoplásicas Circulantes , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Neoplasias Colorretais/patologia , Hibridização Genômica Comparativa , Análise Mutacional de DNA , Feminino , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Masculino , Neoplasias da Próstata/patologia , Análise de Célula Única
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...