1.
Interact Cardiovasc Thorac Surg ; 18(1): 137-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24092466

RESUMO

Transcatheter valve implantation (TAVI) is becoming a routine procedure to treat severe symptomatic aortic stenosis. It is associated with complications different from those of conventional aortic valve surgery. We describe an 80-year old man who developed an apical left ventricular (LV) false aneurysm 3 months after transapical TAVI (TA-TAVI) complicated postoperatively by a surgical site infection (SSI). Three months earlier, an Edwards Sapien bioprosthesis no. 29 had been successfully inserted transapically because of severe comorbidities and a very large aortic annulus. His postoperative course was complicated by acute respiratory failure, gastrointestinal bleeding and a surgical site infection of the thoracic incision; Escherichia coli and Klebsiella pneumonia were isolated. After surgical debridement drainage and prolonged antibiotic therapy, the wound healed correctly. His emergency chest computed tomography upon readmission for the acute onset of a beating tumefaction at the TA-TAVI site showed a false aneurysm of the LV apex. The apex was closed directly during emergency surgery. The postoperative course was uneventful. Surgical site infection after TA-TAVI, its frequency, treatment and potential role as an underlying cause of this severe complication are discussed.


Assuntos
Falso Aneurisma/etiologia , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Aneurisma Cardíaco/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ventrículos do Coração , Infecção da Ferida Cirúrgica/etiologia , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico , Falso Aneurisma/microbiologia , Falso Aneurisma/cirurgia , Estenose da Valva Aórtica/diagnóstico , Bioprótese , Cateterismo Cardíaco/instrumentação , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/microbiologia , Aneurisma Cardíaco/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/microbiologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Desenho de Prótese , Reoperação , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/microbiologia , Infecção da Ferida Cirúrgica/cirurgia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...