Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur Radiol ; 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-37999727

RESUMO

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

2.
Disaster Med Public Health Prep ; 17: e440, 2023 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-37519067

RESUMO

OBJECTIVE: Team dynamics and nontechnical skills in general are crucial for emergency medical teams (EMT). No study has ever examined these important issues during a real mission in the field. This study aimed to better investigate team dynamics and nontechnical skills for EMTs; it tried to understand if a real mission, when the people are obliged to work together for the first time, without a prior specific training focused on teamwork, is enough or not to work as an effective team in the field. METHODS: The study is designed as a pre-test/post-test survey study, and it collected data from 51 people deployed to Mozambique in 2019. Three indexes (the self-efficacy (SE), the teamwork (TW), and the overall team's performance (TW12)) were calculated as the average value of the rating given by all the participants. Open text feedback was also collected. RESULTS: A positive trend was observed comparing the "post" data to the "pre" data, but results did not show a statistical significance, with the only exception of stratified analyses showing a P-value less than 0.05 for SE and TW12 for some categories. CONCLUSIONS: According to the study findings, humanitarian workers feel good but not at their best; training programs focused on team dynamics can be really useful to improve self-confidence of people leaving for a mission.


Assuntos
Desastres , Treinamento por Simulação , Humanos , Moçambique , Treinamento por Simulação/métodos , Competência Clínica , Equipe de Assistência ao Paciente , Percepção
3.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37138190

RESUMO

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia , Mastectomia Segmentar , Mama , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios
4.
Artigo em Inglês | MEDLINE | ID: mdl-36011932

RESUMO

In 2019, an urban ambulance system was deployed in the city of Beira, Mozambique to refer patients from peripheral health centres (HCs) to the only hospital of the city (Beira Central Hospital-HCB). Initially, the system worked following a first-in-first-out approach, thus leading to referrals not based on severity condition. With the aim of improving the process, the South African Triage Scale (SATS) has been subsequently introduced in three HCs. In this study, we assessed the impact of SATS implementation on the selection process and the accuracy of triage performed by nurses. We assessed 552 and 1608 referral charts from before and after SATS implementation, respectively, and we retrospectively calculated codes. We compared the expected referred patients' codes from the two phases, and nurse-assigned codes to the expected ones. The proportion of referred orange and red codes significantly increased (+12.2% and +12.9%) while the proportion of green and yellow codes decreased (-18.7% and -5.8%). The overall rates of accuracy, and under- and overtriage were 34.2%, 36.3%, and 29.5%, respectively. The implementation of SATS modified the pattern of referred patients and increased the number of severe cases receiving advanced medical care at HCB. While nurses' accuracy improved with the routine use of the protocol, the observed rates of incorrect triage suggest that further research is needed to identify factors affecting SATS application in this setting.


Assuntos
Ambulâncias , Triagem , Humanos , Serviço Hospitalar de Emergência , Moçambique , Estudos Retrospectivos , África do Sul , Triagem/métodos
5.
Prehosp Disaster Med ; 37(4): 553-557, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35586879

RESUMO

On March 15, 2019, Cyclone Idai made landfall near the port city of Beira in central Mozambique causing significant casualties and serious damage to infrastructure. The Emergency Medical Team Type 2 - Italy Regione Piemonte (EMT2-ITA) was deployed approximately two weeks after the disaster to support the country in need, providing essential medical and surgical care.The EMT2-ITA staff was composed of 77 team members including two rotations and integrating local staff. A total of 1,121 patients (1,183 triage admissions) were treated during the 27 days of field hospital activity; among all the admissions, only few cases (17; 1%) were directly or indirectly attributed to the disaster event. Only three cases of cholera were confirmed and transferred to one of the treatment centers set up in Beira. The EMT2-ITA performed a total of 62 surgical operations (orthopedic, gynecological, general, and plastic surgery), of which more than one-half were elective procedures.The objective of this manuscript is to report the mission of the EMT2-ITA in Mozambique, raising interesting points of discussion regarding the impact of timing on the mission outcomes, the operational and clinical activities in the field hospital, and the great importance to integrate local staff into the team.


Assuntos
Cólera , Tempestades Ciclônicas , Desastres , Humanos , Unidades Móveis de Saúde , Moçambique
6.
Disaster Med Public Health Prep ; 16(3): 1273-1276, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33100254

RESUMO

The 2019 coronavirus disease (COVID-19) pandemic has stressed the health care system in Italy as well as around the world, with hospitals implementing their surge capacity to increase the number of available beds for patients positive to the virus.At the end of March, the Piemonte (Northern Italy) Government decided to build a temporary rapid-assembly emergency hospital for the treatment of mild and moderate COVID-19 patients, converting an existing concert hall in the city of Turin. The decision was prompted not only by the urgent need of hospital beds, but also by a forward-looking approach for the months immediately after the emergency, when it will be essential for conventional hospitals to return to a normal configuration.This paper documents the temporary hospital project, describing the site, the layout and the equipment, the idea behind structural choices, and the staff involved. The aim of the work is to share the experience and to provide some practical recommendations to other professionals who are fighting the COVID-19 pandemic worldwide.


Assuntos
COVID-19 , Capacidade de Resposta ante Emergências , Humanos , Pandemias/prevenção & controle , COVID-19/epidemiologia , SARS-CoV-2 , Hospitais
7.
Eur Radiol ; 32(3): 1611-1623, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34643778

RESUMO

OBJECTIVES: Preoperative breast magnetic resonance imaging (MRI) can inform surgical planning but might cause overtreatment by increasing the mastectomy rate. The Multicenter International Prospective Analysis (MIPA) study investigated this controversial issue. METHODS: This observational study enrolled women aged 18-80 years with biopsy-proven breast cancer, who underwent MRI in addition to conventional imaging (mammography and/or breast ultrasonography) or conventional imaging alone before surgery as routine practice at 27 centers. Exclusion criteria included planned neoadjuvant therapy, pregnancy, personal history of any cancer, and distant metastases. RESULTS: Of 5896 analyzed patients, 2763 (46.9%) had conventional imaging only (noMRI group), and 3133 (53.1%) underwent MRI that was performed for diagnosis, screening, or unknown purposes in 692/3133 women (22.1%), with preoperative intent in 2441/3133 women (77.9%, MRI group). Patients in the MRI group were younger, had denser breasts, more cancers ≥ 20 mm, and a higher rate of invasive lobular histology than patients who underwent conventional imaging alone (p < 0.001 for all comparisons). Mastectomy was planned based on conventional imaging in 22.4% (MRI group) versus 14.4% (noMRI group) (p < 0.001). The additional planned mastectomy rate in the MRI group was 11.3%. The overall performed first- plus second-line mastectomy rate was 36.3% (MRI group) versus 18.0% (noMRI group) (p < 0.001). In women receiving conserving surgery, MRI group had a significantly lower reoperation rate (8.5% versus 11.7%, p < 0.001). CONCLUSIONS: Clinicians requested breast MRI for women with a higher a priori probability of receiving mastectomy. MRI was associated with 11.3% more mastectomies, and with 3.2% fewer reoperations in the breast conservation subgroup. KEY POINTS: • In 19% of patients of the MIPA study, breast MRI was performed for screening or diagnostic purposes. • The current patient selection to preoperative breast MRI implies an 11% increase in mastectomies, counterbalanced by a 3% reduction of the reoperation rate. • Data from the MIPA study can support discussion in tumor boards when preoperative MRI is under consideration and should be shared with patients to achieve informed decision-making.


Assuntos
Neoplasias da Mama , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mastectomia , Mastectomia Segmentar , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Adulto Jovem
8.
Eur Radiol ; 30(10): 5427-5436, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32377813

RESUMO

Despite its high diagnostic performance, the use of breast MRI in the preoperative setting is controversial. It has the potential for personalized surgical management in breast cancer patients, but two of three randomized controlled trials did not show results in favor of its introduction for assessing the disease extent before surgery. Meta-analyses showed a higher mastectomy rate in women undergoing preoperative MRI compared to those who do not. Nevertheless, preoperative breast MRI is increasingly used and a survey from the American Society of Breast Surgeons showed that 41% of respondents ask for it in daily practice. In this context, a large-scale observational multicenter international prospective analysis (MIPA study) was proposed under the guidance of the European Network for the Assessment of Imaging in Medicine (EuroAIM). The aims were (1) to prospectively and systematically collect data on consecutive women with a newly diagnosed breast cancer, not candidates for neoadjuvant therapy, who are offered or not offered breast MRI before surgery according to local practice; (2) to compare these two groups in terms of surgical and clinical endpoints, adjusting for covariates. The underlying hypotheses are that MRI does not cause additional mastectomies compared to conventional imaging, while reducing the reoperation rate in all or in subgroups of patients. Ninety-six centers applied to a web-based call; 36 were initially selected based on volume and quality standards; 27 were active for enrollment. On November 2018, the target of 7000 enrolled patients was reached. The MIPA study is presently at the analytic phase. Key Points • Breast MRI has a high diagnostic performance but its utility in the preoperative setting is controversial. • A large-scale observational multicenter prospective study was launched to compare women receiving with those not receiving preoperative MRI. • Twenty-seven centers enrolled more than 7000 patients. The study is presently at the analytic phase.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Protocolos de Ensaio Clínico como Assunto , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios , Idoso , Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação
9.
Eur Radiol ; 28(11): 4783-4791, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29796918

RESUMO

OBJECTIVES: To determine whether (1) computer-based self-training for CT colonography (CTC) improves interpretation performance of novice readers; (2) computer-aided detection (CAD) use during training affects learning. METHODS: Institutional review board approval and patients' informed consent were obtained for all cases included in this study. Twenty readers (17 radiology residents, 3 radiologists) with no experience in CTC interpretation were recruited in three centres. After an introductory course, readers performed a baseline assessment test (37 cases) using CAD as second reader. Then they were randomized (1:1) to perform either a computer-based self-training (150 cases verified at colonoscopy) with CAD as second reader or the same training without CAD. The same assessment test was repeated after completion of the training programs. Main outcome was per lesion sensitivity (≥ 6 mm). A generalized estimating equation model was applied to evaluate readers' performance and the impact of CAD use during training. RESULTS: After training, there was a significant improvement in average per lesion sensitivity in the unassisted phase, from 74% (356/480) to 83% (396/480) (p < 0.001), and in the CAD-assisted phase, from 83% (399/480) to 87% (417/480) (p = 0.021), but not in average per patient sensitivity, from 93% (390/420) to 94% (395/420) (p = 0.41), and specificity, from 81% (260/320) to 86% (276/320) (p = 0.15). No significant effect of CAD use during training was observed on per patient sensitivity and specificity, nor on per lesion sensitivity. CONCLUSIONS: A computer-based self-training program for CTC improves readers' per lesion sensitivity. CAD as second reader does not have a significant impact on learning if used during training. KEY POINTS: • Computer-based self-training for CT colonography improves per lesion sensitivity of novice readers. • Self-training program does not increase per patient specificity of novice readers. • CAD used during training does not have significant impact on learning.


Assuntos
Algoritmos , Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Diagnóstico por Computador/métodos , Educação de Pós-Graduação em Medicina/métodos , Radiologia/educação , Adulto , Competência Clínica , Colonoscopia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
10.
Eur Radiol ; 26(1): 175-83, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25929945

RESUMO

OBJECTIVES: To compare breast density (BD) assessment provided by an automated BD evaluator (ABDE) with that provided by a panel of experienced breast radiologists, on a multivendor dataset. METHODS: Twenty-one radiologists assessed 613 screening/diagnostic digital mammograms from nine centers and six different vendors, using the BI-RADS a, b, c, and d density classification. The same mammograms were also evaluated by an ABDE providing the ratio between fibroglandular and total breast area on a continuous scale and, automatically, the BI-RADS score. A panel majority report (PMR) was used as reference standard. Agreement (κ) and accuracy (proportion of cases correctly classified) were calculated for binary (BI-RADS a-b versus c-d) and 4-class classification. RESULTS: While the agreement of individual radiologists with the PMR ranged from κ = 0.483 to κ = 0.885, the ABDE correctly classified 563/613 mammograms (92 %). A substantial agreement for binary classification was found for individual reader pairs (κ = 0.620, standard deviation [SD] = 0.140), individual versus PMR (κ = 0.736, SD = 0.117), and individual versus ABDE (κ = 0.674, SD = 0.095). Agreement between ABDE and PMR was almost perfect (κ = 0.831). CONCLUSIONS: The ABDE showed an almost perfect agreement with a 21-radiologist panel in binary BD classification on a multivendor dataset, earning a chance as a reproducible alternative to visual evaluation. KEY POINTS: Individual BD assessment differs from PMR with κ as low as 0.483. An ABDE correctly classified 92 % of mammograms with almost perfect agreement (κ = 0.831). An ABDE can be a valid alternative to subjective BD assessment.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Processamento Eletrônico de Dados/métodos , Glândulas Mamárias Humanas/anormalidades , Mamografia/métodos , Estadiamento de Neoplasias/métodos , Densidade da Mama , Neoplasias da Mama/classificação , Feminino , Humanos , Curva ROC , Reprodutibilidade dos Testes
11.
Radiology ; 277(1): 56-63, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25961633

RESUMO

PURPOSE: To evaluate a commercial tomosynthesis computer-aided detection (CAD) system in an independent, multicenter dataset. MATERIALS AND METHODS: Diagnostic and screening tomosynthesis mammographic examinations (n = 175; cranial caudal and mediolateral oblique) were randomly selected from a previous institutional review board-approved trial. All subjects gave informed consent. Examinations were performed in three centers and included 123 patients, with 132 biopsy-proven screening-detected cancers, and 52 examinations with negative results at 1-year follow-up. One hundred eleven lesions were masses and/or microcalcifications (72 masses, 22 microcalcifications, 17 masses with microcalcifications) and 21 were architectural distortions. Lesions were annotated by radiologists who were aware of all available reports. CAD performance was assessed as per-lesion sensitivity and false-positive results per volume in patients with negative results. RESULTS: Use of the CAD system showed per-lesion sensitivity of 89% (99 of 111; 95% confidence interval: 81%, 94%), with 2.7 ± 1.8 false-positive rate per view, 62 of 72 lesions detected were masses, 20 of 22 were microcalcification clusters, and 17 of 17 were masses with microcalcifications. Overall, 37 of 39 microcalcification clusters (95% sensitivity, 95% confidence interval: 81%, 99%) and 79 of 89 masses (89% sensitivity, 95% confidence interval: 80%, 94%) were detected with the CAD system. On average, 0.5 false-positive rate per view were microcalcification clusters, 2.1 were masses, and 0.1 were masses and microcalcifications. CONCLUSION: A digital breast tomosynthesis CAD system can allow detection of a large percentage (89%, 99 of 111) of breast cancers manifesting as masses and microcalcification clusters, with an acceptable false-positive rate (2.7 per breast view). Further studies with larger datasets acquired with equipment from multiple vendors are needed to replicate the findings and to study the interaction of radiologists and CAD systems.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Mamografia/métodos , Intensificação de Imagem Radiográfica , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...