Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 13(9): 1071-1082, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32305398

RESUMO

OBJECTIVES: The purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years. BACKGROUND: The CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV. METHODS: The CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device. The primary endpoint was device success. Patients were followed up to 5 years, with assessment of clinical outcomes, and echocardiographic evaluation of valve function and THV durability. RESULTS: After 5 years, there were no statistically significant differences between BE and SE valves in the cumulative incidence of death from any cause (53.4% vs. 47.6%; p = 0.38), death from cardiovascular causes (31.6% vs. 21.5%; p = 0.12), all strokes (17.5% vs. 16.5%; p = 0.73), and repeat hospitalization for heart failure (28.9% vs. 22.5%; p = 0.75). SE patients had larger prosthetic valve area (1.6 ± 0.5 cm2 vs. 1.9 ± 0.5 cm2; p = 0.02) with a lower mean transprosthetic gradient (12.2 ± 8.7 mm Hg vs. 6.9 ± 2.7 mm Hg; p = 0.001) at 5 years. No differences were observed in the rates of paravalvular regurgitation. Clinical valve thrombosis occurred in 7 BE patients (7.3%) and 1 SE patient (0.8%; p = 0.06), and moderate or severe structural valve deterioration in 6 BE patients (6.6%) and no SE patient (0%; p = 0.018). The rate of bioprosthetic valve failure was low and not significantly different between both groups (4.1% vs. 3.4%; p = 0.63). CONCLUSIONS: Five-year follow-up of patients in the CHOICE trial revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with early-generation BE and SE valves that were not statistically significantly different, with limited statistical power. Forward flow hemodynamics were significantly better with the SE valve. Moderate or severe structural valve deterioration was uncommon but occurred more frequently with the BE valve. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial [CHOICE]; NCT01645202).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Feminino , Alemanha , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 11(24): 2507-2518, 2018 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-30503595

RESUMO

OBJECTIVES: The aim of this study was to compare self-expanding and balloon-expandable transcatheter heart valves (THVs) in large versus small aortic valve annuli. BACKGROUND: The degree of THV oversizing varies according to annular size, and this can modify the hemodynamic performance of self-expanding and balloon-expandable THVs. METHODS: Patients undergoing transcatheter aortic valve replacement in the randomized CHOICE (Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve vs Edwards SAPIEN XT) trial (CoreValve [CV], n = 120; SAPIEN XT [SXT], n = 121) and the nonrandomized CHOICE-Extend registry (Evolut R [ER], n = 100; SAPIEN 3 [S3], n = 334) were compared for THV performance by echocardiography (in all patients) and by cardiac magnetic resonance imaging (MRI) regurgitant fraction (RF) (in a subgroup of patients). Patients were stratified according to aortic valve annular mean diameter into those with large (>23 mm) or small (≤23 mm) annuli. RESULTS: THV percentage oversizing was 19.1 ± 6.4% with the CV, 11.4 ± 7.0% with the SXT, 18.8 ± 4.8% with the ER, and 3.7 ± 5.5% with the S3. Transvalvular mean pressure gradient was lower with the CV and ER than with the SXT and S3 in both the large and small annulus groups. In the randomized CHOICE trial, moderate to severe prosthetic valve regurgitation (PVR) was more with the CV than the SXT in large annuli (15.1% vs. 0.0%; p = 0.002; MRI RF: 10.5 ± 10.2% vs. 4.4 ± 4.5%; p = 0.036) but not in small annuli (0.0% vs. 5.7%; p = 0.50; MRI RF: 4.0 ± 4.1% vs. 4.0 ± 3.4%; p = 0.98). In the CHOICE-Extend registry, moderate to severe PVR occurred in 2 patients, and any PVR was not significantly different between the ER and the S3 in large (41.7% vs. 32.5%; p = 0.24) or small (47.1% vs. 43.8%; p = 0.84) annuli. MRI RF was not different in large annuli (5.0 ± 3.8% vs. 5.0 ± 6.1%; p = 0.99) but was significantly lower with the ER than the S3 in small annuli (2.9 ± 2.3% vs. 4.8 ± 3.7%; p = 0.023). On multivariate analysis, transcatheter aortic valve replacement with the ER in small annuli was associated with a lower rate of prosthesis-patient mismatch than with the S3, with no increased risk for PVR. CONCLUSIONS: Older-generation balloon-expandable THVs were associated with less PVR than self-expanding THVs in patients with large but not small annuli. The next-generation self-expanding THV has improved sealing in patients with large annuli and may have potential advantages in patients with small annuli.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
EuroIntervention ; 14(4): e390-e396, 2018 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-29741488

RESUMO

AIMS: Long-term results of transcatheter aortic valve implantation (TAVI), in particular the incidence of bioprosthetic valve failure (BVF), are uncertain. This study presents data derived from a long-term, structured follow-up programme of the self-expanding CoreValve device utilising standardised definitions and core lab adjudication of valve performance. METHODS AND RESULTS: The study prospectively included all 152 patients who had undergone TAVI with the self-expanding CoreValve up to December 2011 at the Heart Center, Bad Segeberg, Germany. Late BVF (>30 days) was defined as either: 1) severe structural valve deterioration (transprosthetic mean pressure gradient ≥40 mmHg and/or ≥20 mmHg rise from baseline OR severe intraprosthetic aortic regurgitation), OR 2) bioprosthetic valve dysfunction leading to death or reintervention. Echocardiographic follow-up at 6.3±1.0 years (range: 5.0-8.9 years) was 88% complete (60 out of 68 survivors beyond five years) and all echocardiograms were analysed by an independent core laboratory. The all-cause mortality rate at 1, 2, 5, 6, 7 and 8 years was 14%, 20%, 50%, 60%, 65%, and 73%, respectively. Among survivors beyond five years, effective orifice area was 1.60±0.46 cm2, and transvalvular mean pressure gradient was 6.7±3.1 mmHg; no cases showed evidence of structural valve deterioration. Five patients (3.3%) had undergone redo TAVI (n=4) or surgery (n=1) 0.6 to 5.2 years after the index procedure, all due to paravalvular leakage. The estimated rate of BVF at eight years was 7.9% for the actuarial and 4.5% for the actual analysis. CONCLUSIONS: Long-term follow-up up to 8.9 years after TAVI documents favourable performance of the self-expanding CoreValve with low rates of BVF.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Alemanha , Hemodinâmica , Humanos , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...