Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Exp Dent Res ; 8(3): 763-770, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35187813

RESUMO

OBJECTIVES: Restoration fit is one of the prerequisites of clinical durability. It is controversial as to whether computer-assisted design/computer-aided milling (CAD/CAM) or lost-wax fabrication methods result in more fit metal-ceramic crowns. This in-vitro study was conducted to examine the internal fit of porcelain fused to metal crowns fabricated using CAD/CAM and lost-wax techniques during fabrication stages (framework, porcelain, cementation) through digital triple scanning, replica weighting, and observation with electron microscopy. MATERIAL AND METHODS: Twenty uniform resin dies of prepared first maxillary molars were randomly divided into two groups according to the fabrication technique: lost wax and CAD/CAM. The internal fit was measured in all steps of completing the crowns (framework, porcelain, and cementation) using different methods, including triple scanning, replica weighting, and scanning electron microscopy. The data were statistically analyzed using t test, Pearson, and repeated measures analysis of variance (α = .05). RESULTS: Triple scanning revealed no difference in the internal fit of CAD/CAM and lost-wax groups in all the fabrication steps (p > .05). The replica weighting method showed no difference between groups in the framework step (p > .05), while the internal fit was significantly better in the CAD/CAM group after porcelain application (p < .05). After cementation, electron microscopy measurements showed no difference between CAD/CAM and lost wax groups (p > .05). The Pearson correlation test showed no significant correlation between electron microscopy, replica weighing, and triple scanning methods (p > .05). CONCLUSION: According to scanning electron microscopy as the superior evaluation method, the internal fit of cobalt-chrome PFM crown of both CAD/CAM and lost wax groups was within the acceptable clinical range and there was no significant difference between them. Triple scanning revealed no difference in the internal fit of framework and porcelain steps but a better fit after cementation. According to replica weighting, the internal fit in the porcelain step was higher than the framework.


Assuntos
Adaptação Marginal Dentária , Porcelana Dentária , Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária/métodos , Microscopia Eletrônica de Varredura
2.
Dent Med Probl ; 57(4): 417-422, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33444489

RESUMO

BACKGROUND: Computer-aided design/computer-aided manufacturing (CAD/CAM) systems are widely used for the fabrication of porcelain-fused-to-metal (PFM) crowns. OBJECTIVES: This study was conducted to compare PFM crowns through triple scanning in terms of marginal discrepancy between the CAD/CAM and lost-wax fabrication techniques. MATERIAL AND METHODS: Twenty uniform resin dies of a prepared maxillary first molar were randomly divided into 2 groups: conventional lost-wax; and milling. Marginal discrepancy was evaluated at the framework and porcelain steps through triple scanning and direct visualization under a stereomicroscope. Then, the crowns were cemented to the related die and the marginal gap was measured with triple scanning, direct visualization under a stereomicroscope and scanning electron microscopy (SEM). The data was analyzed using the independent t test and the one-way analysis of variance (ANOVA). The significance level was set at 0.05. RESULTS: Differences in the mean marginal gap were measured by the various evaluation methods. Triple scanning and stereomicroscopy identified increasing discrepancy during the fabrication process. According to the results of the independent t test, stereomicroscopy showed no difference after cementation between the CAD/CAM and lost-wax groups (p > 0.05), triple scanning showed higher fitness in the CAD/CAM group (p < 0.05), and SEM showed better adaptation in the lost-wax group (p < 0.05); however, there was a positive correlation between the findings of stereomicroscopy and SEM (p < 0.05). CONCLUSIONS: The cobalt-chromium crowns had clinically acceptable marginal fitness from both the CAD/CAM and lost-wax techniques; however, the lost-wax group showed lower marginal discrepancy after cementation according to SEM.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...