Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Eng Online ; 22(1): 24, 2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36899353

RESUMO

BACKGROUND: Heart auscultation is an easy and inexpensive tool for early diagnosis of congenital heart defects. In this regard, a simple device which can be used easily by physicians for heart murmur detection will be very useful. The current study was conducted to evaluate the validity of a Doppler-based device named "Doppler Phonolyser" for the diagnosis of structural heart diseases in pediatric patients. In this cross-sectional study, 1272 patients under 16 years who were referred between April 2021 and February 2022, to a pediatric cardiology clinic in Mofid Children Hospital, Tehran, Iran, were enrolled. All the patients were examined by a single experienced pediatric cardiologist using a conventional stethoscope at the first step and a Doppler Phonolyser device at the second step. Afterward, the patient underwent trans-thoracic echocardiography, and the echocardiogram results were compared with the conventional stethoscope as well as the Doppler Phonolyser findings. RESULTS: Sensitivity of the Doppler Phonolyser for detecting congenital heart defects was 90.5%. The specificity of the Doppler Phonolyser in detecting heart disease was 68.9% in compared with the specificity of the conventional stethoscope, which was 94.8%. Among the most common congenital heart defects in our study population, the sensitivity of the Doppler Phonolyser was 100% for detection of tetralogy of Fallot (TOF); In contrast, sensitivity of both the conventional stethoscope and the Doppler Phonolyser was relatively low for detecting atrial septal defect. CONCLUSIONS: Doppler Phonolyser could be useful as a diagnostic tool for the detection of congenital heart defects. The main advantages of the Doppler Phonolyser over the conventional stethoscope are no need for operator experience, the ability to distinguish innocent murmurs from the pathologic ones and no effect of environmental sounds on the performance of the device.


Assuntos
Cardiopatias Congênitas , Ruídos Cardíacos , Humanos , Criança , Estudos Transversais , Sensibilidade e Especificidade , Irã (Geográfico) , Sopros Cardíacos , Cardiopatias Congênitas/diagnóstico
2.
Biopreserv Biobank ; 20(4): 374-383, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35984941

RESUMO

Cryopreservation of spermatogonial stem cells (SSCs) is an important method to restore and maintain fertility in preadolescent children suffering from cancer. For protection of SSCs from cryoinjury, various antioxidant agents have been used. The aim of this study was to assess the antiapoptotic and antioxidant effects of melatonin in frozen-thawed SSCs. SSCs were isolated from testes of neonatal mice (3-6 days old) and their purities were measured by flow cytometry with promyelocytic leukemia zinc finger protein. After culturing, the cells were frozen in two groups (1) control and (2) melatonin (100 µM) and stored for 1 month. Finally, the cell viability, colonization rate, expression of Bcl-2 and BAX gene, and intracellular reactive oxygen species (ROS) were evaluated after freezing-thawing. Melatonin increased the viability and colonization of SSCs and Bcl-2 gene expression. It also diminished BAX gene expression and intracellular ROS. The results of this study show that melatonin with antioxidant and antiapoptotic effects can be used as an additive for freezing and long-term storage of cells and infertility treatment in the clinic.


Assuntos
Antioxidantes , Melatonina , Espermatogônias , Animais , Animais Recém-Nascidos , Antioxidantes/farmacologia , Apoptose , Proliferação de Células , Criopreservação/métodos , Congelamento , Masculino , Melatonina/farmacologia , Camundongos , Estresse Oxidativo , Proteínas Proto-Oncogênicas c-bcl-2/genética , Espécies Reativas de Oxigênio , Espermatogônias/efeitos dos fármacos , Células-Tronco/efeitos dos fármacos , Proteína X Associada a bcl-2
3.
Nurs Midwifery Stud ; 3(2): e14097, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25414899

RESUMO

BACKGROUND: One of the measures to keep the airway open is suctioning of endotracheal tube in patients under ventilation. This procedure can be accompanied with some complications. Selection of appropriate method of suctioning can prevent incidence of acute complications. OBJECTIVES: This study aimed to compare the effects of the open and closed system suctioning methods on blood pressure, mean arterial pressure, heart rate, percentage of arterial oxygen saturation, time, and costs in patients under mechanical ventilation. PATIENTS AND METHODS: This clinical trial study was conducted on 40 patients in ICU. Patients' blood pressure, heart rate, arterial oxygen saturation, related costs, and length of suctioning procedure were measured and recorded immediately before and one, five, ten, and fifteen minutes after suctioning. Data were analyzed using paired t test and repeated measure analysis of variance. RESULTS: No significant differences were observed between the two suctioning methods in terms of mean systolic blood pressure (P = 0.075), diastolic blood pressure (P = 0.405), and mean arterial pressure (P = 0.257) in the five consecutive measurements. However, significant changes were observed in heart rate (P = 0.025) and percentage of arterial oxygen saturation (P < 0.001). The mean lengths of time in open and closed suctioning methods were 5.59 ± 0.211 and 4.34 ± 0.039 seconds, respectively (P < 0.001). The cost of the closed system was lower than the open method for the patients who were admitted to ICU for longer than two days. CONCLUSIONS: Closed suction caused fewer disturbances in patients' hemodynamic condition, took shorter time, and is more economical. Therefore, this method can replace open suction method in caring of severely critically ill patients.

4.
Iran J Nurs Midwifery Res ; 19(1): 64-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24554962

RESUMO

BACKGROUND: Hypothermia is one of the problems occurring during surgery, which can happen due to thermoregulation mechanism disorders and intake of low temperature IV fluids, and may cause increase in blood pressure, heart rate, intracranial pressure, oxygen consumption, pain, and discomfort to the patient. The rate of cesarean section in our country is three times more than the global standard. As one of the responsibilities of the nurse is patient's advocacy, s/he should support them. This study aimed to investigate the effect of pre-warmed intravenous fluids on prevention of hypothermia during general anesthesia in cesarean section. MATERIALS AND METHODS: Sixty-two women undergoing elective cesarean section by general anesthesia were randomly allocated in two groups of intervention and control. Women in the intervention group received pre-warmed serum (37°C) while those in the control group received serum at room temperature (25.5°C). The core body temperature and some hemodynamic parameters of the participants were assessed during the operation. RESULTS: The mean of pulse rate, systolic blood pressure, diastolic blood pressure, and arterial O2 saturation in the two groups were not statistically significant (P > 0.05). But the mean of mothers' core body temperature at the end of anesthesia in the intervention and control groups were 36 ± 0.5°C and 35.34 ± 0.6°C, respectively (P < 0.05). CONCLUSION: Infusion of pre-warmed serum (37°C) would prevent intraoperative hypothermia and improve the nursing care for women who undergo cesarean section by general anesthesia.

5.
Iran J Nurs Midwifery Res ; 15(4): 155-66, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21589789

RESUMO

BACKGROUND: In spite of much literature written about the theory-practice gap in the international nursing journals, there is evidence that indicates this subject has not been probed comprehensively since nursing education was transferred to universities in Iran. In the recent years, the public and the government have criticized Iranian nurses because of poor quality of patient care. Although this subject has been lamented by some researchers, there is no comprehensive work on how this gap resulted. In the process of a larger study on "nursing knowledge translation to practice", of one PhD thesis, this process was explored. METHODS: Using grounded theory analysis, indepth interviews were undertaken with a purposive sample of 29 nurses, with different levels of experience, from the school of nursing in Tehran University of Medical Sciences in 2006 from January to August. Data were analyzed using the constant comparative method. RESULTS: Three main themes emerging from this study included clinical behavior structure, paradoxical knowledge and practice, and divergent nursing organization. CONCLUSIONS: It seems that nursing education with some praxis and paradoxes in the realm of nursing knowledge and practice, along with divergent organizational structure have decreased nurses' ability in applying their professional knowledge and skills in order to bridge the gap between theory and practice. Moreover, in spite of increased academic input into nursing education, clinical behaviors of both education and practice settings was perceived as "traditional routine-based".

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...