Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Environ Res ; 261: 119713, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39094896

RESUMO

Indoor air quality (IAQ) in educational facilities is crucial due to the extended time students spend in those environments, affecting their health, academic performance, and attendance. This paper aimed to review relevant parameters (building characteristics and factors related with occupancy and activities) for assessing IAQ in educational facilities, and to identify the parameters to consider when performing an IAQ monitoring campaign in schools. It also intended to identify literature gaps and suggest future research directions. A narrative literature review was conducted, focusing on seven key parameters: building location, layout and construction materials, ventilation and air cleaning systems, finishing materials, occupant demographics, occupancy, and activities. The findings revealed that carbon dioxide (CO2) levels were predominantly influenced by classroom occupancy and ventilation rates, while particulate matter (PM) concentrations were significantly influenced by the building's location, design, and occupant activities. Furthermore, this review highlighted the presence of other pollutants, such as trace metals, polycyclic aromatic hydrocarbons (PAHs), carbon monoxide (CO), nitrogen dioxide (NO2), ozone (O3), and radon, linking them to specific factors within the school environment. Different IAQ patterns, and consequently different parameters, were observed in various school areas, including classrooms, canteens, gymnasiums, computer rooms, and laboratories. While substantial literature exists on IAQ in schools, significant gaps still remain. This study highlighted the need for more studies in middle and high schools, as well as in other indoor microenvironments within educational settings beyond classrooms. Additionally, it underscored the need for comprehensive exposure assessments, long-term studies, and the impacts of new materials on IAQ including the effects of secondary reactions on surfaces. Seasonal variations and the implications of emerging technologies were also identified as requiring further investigation. Addressing those gaps through targeted research and considering the most updated standards and guidelines for IAQ, could lead to define more effective strategies for improving IAQ and safeguarding the students' health and performance.

2.
Indoor Air ; 32(11): e13144, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36437669

RESUMO

Indoor air in residential dwellings can contain a variety of chemicals, sometimes present at concentrations or in combinations which can have a negative impact on human health. Indoor Air Quality (IAQ) surveys are often required to characterize human exposure or to investigate IAQ concerns and complaints. Such surveys should include sufficient contextual information to elucidate sources, pathways, and the magnitude of exposures. The aim of this review was to investigate and describe the parameters that affect IAQ in residential dwellings: building location, layout, and ventilation, finishing materials, occupant activities, and occupant demography. About 180 peer-reviewed articles, published from 01/2013 to 09/2021 (plus some important earlier publications), were reviewed. The importance of the building parameters largely depends on the study objectives and whether the focus is on a specific pollutant or to assess health risk. When considering classical pollutants such as particulate matter (PM) or volatile organic compounds (VOCs), the building parameters can have a significant impact on IAQ, and detailed information of these parameters needs to be reported in each study. Research gaps and suggestions for the future studies together with recommendation of where measurements should be done are also provided.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluentes Ambientais , Humanos , Poluição do Ar em Ambientes Fechados/análise , Poluentes Atmosféricos/análise , Monitoramento Ambiental , Material Particulado/análise
3.
ACS Sens ; 7(1): 304-311, 2022 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-34958564

RESUMO

The selective detection of individual hazardous volatile organic compounds (VOCs) within a mixture is of great importance in industrial contexts due to environmental and health concerns. Achieving this with inexpensive, portable detectors continues to be a significant challenge. Here, a novel thermal separator system coupled with a photoionization detector has been developed, and its ability to selectively detect the VOCs isopropanol and 1-octene from a mixture of the two has been studied. The system includes a nanoporous silica preconcentrator in conjunction with a commercially available photoionization detector (PID). The PID is a broadband total VOC sensor with little selectivity; however, when used in conjunction with our thermal desorption approach, selective VOC detection within a mixture can be achieved. VOCs are adsorbed in the nanoporous silica over a 5 min period at 5 °C before being desorbed by heating at a fixed rate to 70 °C and detected by the PID. Different VOCs desorb at different times/temperatures, and mathematical analysis of the set of PID responses over time enabled the contributions from isopropanol and 1-octene to be separated. The concentrations of each compound individually could be measured in a mixture with limits of detection less than 10 ppbv and linearity errors less than 1%. Demonstration of a separation of a mixture of chemically similar compounds, benzene and o-xylene, is also provided.


Assuntos
Nanoporos , Compostos Orgânicos Voláteis , 2-Propanol/análise , Cromatografia Gasosa , Dióxido de Silício , Compostos Orgânicos Voláteis/análise
4.
ACS Sens ; 6(11): 3985-3993, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34672617

RESUMO

In this paper, the physical chemistry of the absorption and desorption of water vapor for electrochemical gas sensors with commonly used sulfuric acid as the electrolyte is investigated. Electrochemical gas sensors are being increasingly used for monitoring toxic gases in the environment, and they are, in principle, simple devices, but in practice, their operation is complex. In particular, changes in atmospheric humidity and temperature can have significant effects on the sensor output. A model has been developed for the calculation of sensor weight changes as humidity varies, which are in good agreement with the analysis of experimental results. This then allows for the calculation of the rather more important electrolyte volume variations. Changes in acid molarity and physical characteristics of the electrolyte have also been determined. The effects on working electrode (WE) electrocatalytic activity are discussed, and potential problems with sensors for environmental monitoring are highlighted. In particular, changes in the electroactive area of the WE and, consequently, of the sensor output, and flooding of the WE catalyst aggregates which can lead to problems with electrolyte leakage from sensors are considered.


Assuntos
Eletrólitos , Gases , Umidade , Cinética , Termodinâmica
5.
Sci Rep ; 10(1): 8700, 2020 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-32457500

RESUMO

A novel suite of instrumentation for the characterisation of materials held inside an air-tight tube furnace operated up to 250 °C has been developed. Real-time detection of released gases (volatile organic compounds (VOCs), CO2, NO, NO2, SO2, CO and O2) was achieved combining commercial off-the-shelf (COTS) gas sensors and sorbent tubes for further qualitative and semi-quantitative analysis by gas chromatography-mass spectrometry coupled to thermal desorption (TD-GC-MS). The test system was designed to provide a controlled flow (1000 cm3 min-1) of hydrocarbon free air through the furnace. The furnace temperature ramp was set at a rate of 5 °C min-1 with 10 min dwell points at 70 °C, 150 °C, 200 °C and 250 °C to allow time for stabilisation and further headspace sampling onto sorbent tubes. Experimental design of the instrumentation is described here and an example data set upon exposure to a gas sample is presented.

6.
Sensors (Basel) ; 18(9)2018 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-30149560

RESUMO

There is increasing concern about the health impacts of ambient Particulate Matter (PM) exposure. Traditional monitoring networks, because of their sparseness, cannot provide sufficient spatial-temporal measurements characteristic of ambient PM. Recent studies have shown portable low-cost devices (e.g., optical particle counters, OPCs) can help address this issue; however, their application under ambient conditions can be affected by high relative humidity (RH) conditions. Here, we show how, by exploiting the measured particle size distribution information rather than PM as has been suggested elsewhere, a correction can be derived which not only significantly improves sensor performance but which also retains fundamental information on particle composition. A particle size distribution⁻based correction algorithm, founded on κ -Köhler theory, was developed to account for the influence of RH on sensor measurements. The application of the correction algorithm, which assumed physically reasonable κ values, resulted in a significant improvement, with the overestimation of PM measurements reduced from a factor of ~5 before correction to 1.05 after correction. We conclude that a correction based on particle size distribution, rather than PM mass, is required to properly account for RH effects and enable low cost optical PM sensors to provide reliable ambient PM measurements.

7.
ACS Sens ; 2(11): 1553-1566, 2017 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-29025261

RESUMO

This review examines the use of amperometric electrochemical gas sensors for monitoring inorganic gases that affect urban air quality. First, we consider amperometric gas sensor technology including its development toward specifically designed air quality sensors. We then review recent academic and research organizations' studies where this technology has been trialed for air quality monitoring applications: early studies showed the potential of electrochemical gas sensors when colocated with reference Air Quality Monitoring (AQM) stations. Spatially dense networks with fast temporal resolution provide information not available from sparse AQMs with longer recording intervals. We review how this technology is being offered as commercial urban air quality networks and consider the remaining challenges. Sensors must be sensitive, selective, and stable; air quality monitors/nodes must be electronically and mechanically well designed. Data correction is required and models with differing levels of sophistication are being designed. Data analysis and validation is possibly the biggest remaining hurdle needed to deliver reliable concentration readings. Finally, this review also considers the roles of companies, urban infrastructure requirements, and public research in the development of this technology.


Assuntos
Poluição do Ar/análise , Custos e Análise de Custo , Eletroquímica/economia , Eletroquímica/instrumentação , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Gases/análise , Humanos
8.
Appl Opt ; 54(27): 8135-44, 2015 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-26406516

RESUMO

We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10(-4) AU for the AvaSpec-3648 and 5.6×10(-4) AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance.


Assuntos
Espectrofotometria Ultravioleta/métodos , Espectrofotometria/métodos , Desenho de Equipamento , Luz , Dispositivos Ópticos , Distribuição de Poisson , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Espectrofotometria/instrumentação , Espectrofotometria Ultravioleta/instrumentação , Temperatura , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA