Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Occup Hyg ; 49(6): 481-92, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15790615

RESUMO

The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 microm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 microm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for d(ae) < 7 microm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Fibras Minerais/análise , Monitoramento Ambiental/métodos , Filtração , Exposição por Inalação/análise , Tamanho da Partícula
2.
Sci Total Environ ; 191(1-2): 153-67, 1996 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-8885428

RESUMO

The first personal exposure data for tungsten oxide fibres, in two hard metal manufacturing industries is presented. Occupational exposure was studied by static and personal measurements during tungsten metal production. Three different initial materials were used, ammonium-paratungstate (APT), blue oxide and tungsten trioxide. In both factories, airborne tungsten oxide fibres were detected both in static and personal samples. Fibre exposure varies for different activities. Charging of raw material, changing the hammer, cleaning-work on the cyclone and the micro-filter were found to be among the most high dusty operations. However, as workers use respirators during cleaning operations, these filters could not be related to personal exposure. The calcination of APT to the blue oxide generates fibrous dust. The raw material imported as blue oxide is also fibrous material and both charging it into the calcination furnace and re-charging it into the reduction furnace generates unnecessarily additional dusty periods. A single reduction-stage is, therefore, preferable. Furthermore, the tungsten trioxide raw material is non-fibrous, therefore, calcination of APT to tungsten trioxide and its reduction to tungsten metal is preferable with respect to minimising workers exposure to tungsten oxide fibres.


Assuntos
Metais , Exposição Ocupacional , Compostos de Tungstênio/toxicidade , Poluentes Ocupacionais do Ar/análise , Poluentes Ocupacionais do Ar/toxicidade , Poeira/efeitos adversos , Poeira/análise , Humanos , Indústrias , Pneumopatias/etiologia , Microscopia Eletrônica , Doenças Profissionais/etiologia , Compostos de Tungstênio/administração & dosagem , Compostos de Tungstênio/análise
3.
Chest ; 109(3): 837-42, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8617099

RESUMO

Dental technician's pneumoconiosis (DTP) is a rather recent finding in subjects exposed to the dust generated in dental laboratories producing metal-framed removable partial dentures from alloys based on cobalt, chromium, and molybdenum. This study presents details of the first three Swedish cases of DTP with some emphasis on the diagnostic procedures and the dust exposure. A follow-up of at least 5 years from diagnosis is included.


Assuntos
Ligas de Cromo/efeitos adversos , Técnicos em Prótese Dentária , Poeira/efeitos adversos , Pneumoconiose/etiologia , Adulto , Cobalto , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Molibdênio , Pneumoconiose/diagnóstico por imagem , Pneumoconiose/patologia , Pneumoconiose/fisiopatologia , Radiografia , Testes de Função Respiratória
4.
Ann Occup Hyg ; 40(1): 29-44, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9054300

RESUMO

The direct and indirect sample transfer techniques for measuring airborne inorganic fibres concentrations were studied by TEM for airborne rockwool fibres, chrysotile, amosite and tungsten oxide whiskers. The number and mass concentrations of fibres with aspect ratios > or = 5, prepared by these two techniques for fibres longer than 0.5 mu m and 5 mu m, and the aspect ratios were evaluated and compared. It was found that the indirect sample transfer technique affects the fibre size distribution of different materials differently, and that the mass concentrations did not relate to fibre number concentrations of ambient air, irrespective of the sample transfer method used or the materials studied. It is concluded that the direct sample transfer method incorporating the etching stage should be preferred over the indirect method. Moreover, a need for an extra stage in-between the etching and carbon coating stages for the direct sample transfer method is suggested; this would be a stage where soluble materials could be removed.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental , Microscopia Eletrônica , Fibras Minerais/análise , Humanos , Concentração Máxima Permitida , Microscopia de Contraste de Fase , Manejo de Espécimes
5.
Toxicol In Vitro ; 9(2): 175-83, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20650077

RESUMO

Occupational exposure to hard metal dust may cause interstitial pulmonary fibrosis and asthma. The cause of asthma is well established, whereas the cause of lung fibrosis is still under debate. Recently, slightly reduced airborne tunsten oxide fibres, the role of which in hard metal pneumoconiosis has never been accounted for, were detected in an air sample from a hard metal production plant. In this study, the capacity to generate hydroxyl radicals, toxicity to cultured human lung cells and haemolytic activity of tungsten oxide fibres were compared with crocidolite asbestos fibres. The results show (a) that tungsten oxide fibres can generate hydroxyl radicals, and (b) that tunsten oxide fibres were more cytotoxic to human lung cells than was crocidolite, but (c) that the haemolytic activity of tungsten oxide fibres was lower than for crocidolite.

7.
Ann Occup Hyg ; 34(1): 55-75, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2327690

RESUMO

The characteristics of airborne dust in a soft paper production plant have been characterized by scanning and transmission electron microscopy. A combination of X-ray diffraction, electron diffraction and energy-dispersive X-ray flouresence spectroscopy (EDX) was used to determine the structure and composition of the different components. Size distribution determination and phase identification were carried out. Besides the cellulose fibres, fibres of kaolinite, wollastonite, talc and other silicates were also identified. Gravimetric analysis and fibre counting by optical phase contrast microscopy were used to determine total dust and fibre concentrations. Total dust exposure at the plant was generally below 3 mg m-3. The respirable fraction of the total dust concentrations varied from 15 to 70%. The inorganic dust was 36 +/- 15% of the total dust. The ratio of inorganic fibres to total fibre concentration at the plant varied between 10 and 15%.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poeira/análise , Papel , Microanálise por Sonda Eletrônica , Humanos , Microscopia Eletrônica , Tamanho da Partícula
8.
Int Arch Occup Environ Health ; 61(7): 467-71, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2789194

RESUMO

The aim of the present cross-sectional study was to investigate whether long-term exposure to soft paper dust causes impairment of lung function. Exposed workers (n = 287) and referents (n = 79) were investigated, using spirometry and questionnaires. Personal samplings of total dust showed that the actual mean concentrations did not exceed 3 mg/m3. The exposed subjects were divided into three categories according to historical and present exposure to paper dust; low exposure, moderate exposure and high exposure. The study did not show any lung function impairment due to exposure to paper dust. However, the exposed subjects had a significantly increased prevalence of symptoms from both the upper and lower airways as well as an increased prevalence of reported asthma. On the basis of our study, we conclude that lung function impairment does not occur among workers exposed to mean levels of soft paper dust below 5 mg/m3.


Assuntos
Poeira/efeitos adversos , Pneumopatias/etiologia , Doenças Profissionais/etiologia , Papel , Estudos Transversais , Humanos , Doenças Profissionais/fisiopatologia , Espirometria , Suécia
SELEÇÃO DE REFERÊNCIAS