Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Radiol ; 69(4): 410-5, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24411824

RESUMO

AIM: To determine whether a single 20 s breath-hold positron-emission tomography (PET) acquisition obtained during combined PET/computed tomography (CT)-guided percutaneous liver biopsy or ablation procedures has the potential to target 2-[(18)F]-fluoro-2-deoxy-d-glucose (FDG)-avid liver masses as accurately as up to 180 s breath-hold PET acquisitions. MATERIALS AND METHODS: This retrospective study included 10 adult patients with 13 liver masses who underwent FDG PET/CT-guided percutaneous biopsies (n = 5) or ablations (n = 5). PET was acquired as nine sequential 20 s, monitored, same-level breath-hold frames and CT was acquired in one monitored breath-hold. Twenty, 40, 60, and 180 s PET datasets were reconstructed. Two blinded readers marked tumour centres on randomized PET and CT datasets. Three-dimensional spatial localization differences between PET datasets and either 180 s PET or CT were analysed using multiple regression analyses. Statistical tests were two-sided and p < 0.05 was considered significant. RESULTS: Targeting differences between 20 s PET and 180 s PET ranged from 0.7-20.3 mm (mean 5.3 ± 4.4 mm; median 4.3) and were not statistically different from 40 or 60 s PET (p = 0.74 and 0.91, respectively). Targeting differences between 20 s PET and CT ranged from 1.4-36 mm (mean 9.6 ± 7.1 mm; median 8.2 mm) and were not statistically different from 40, 60, or 180 s PET (p = 0.84, 0.77, and 0.35, respectively). CONCLUSION: Single 20 s breath-hold PET acquisitions from PET/CT-guided percutaneous liver procedures have the potential to target FDG-avid liver masses with equivalent accuracy to 180 s summed, breath-hold PET acquisitions and may facilitate strategies that improve image registration and shorten procedure times.


Assuntos
Ablação por Cateter , Biópsia Guiada por Imagem , Neoplasias Hepáticas/patologia , Fígado/patologia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Boston/epidemiologia , Ablação por Cateter/métodos , Feminino , Fluordesoxiglucose F18 , Humanos , Inalação , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/epidemiologia , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Clin Radiol ; 68(3): 264-71, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22974566

RESUMO

AIM: To determine how representative virtual unenhanced (VNE) images are of true unenhanced (TNE) images when performing computed tomography (CT) urography on a dual-energy CT (DECT) system, and whether the images are affected by the contrast material phase. MATERIALS AND METHODS: In this retrospective, institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study, TNE were compared with VNE images derived from the nephrographic (VNEn) and excretory (VNEe) phases in 100 consecutive CT urograms. Two readers in consensus measured attenuation values of abdominal organs, fat, and renal lesions (>1 cm). Image noise was correlated with patient thickness. Detectability of renal stones was evaluated. Image quality and acceptability was assessed using a five-point scale. Expected dose saving by removing the TNE phase was calculated. RESULTS: VNE attenuation values of liver, renal parenchyma, and aorta were significantly different to TNE values (p < 0.05); spleen and fat attenuation values showed no significant difference. No significant difference was found between VNEn and VNEe images. Image noise was significantly greater in TNE images (p < 0.0001) and correlated with patient thickness. VNEn and VNEe images had sensitivities of 76.6 and 65.6% for detection of stones, identifying all stones greater than 3 and 4 mm, respectively. Both VNE images received significantly lower image quality scores than TNE images (p < 0.0001); however, the majority of images were deemed acceptable. The mean theoretical dose saving by removing the TNE phase was 35%. CONCLUSION: Although VNE images demonstrate high reader acceptability, accuracy of attenuation values and detection of small stones is limited. The contrast material phase, however, does not affect attenuation values. Further validation of VNE images is recommended prior to clinical implementation.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Urografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Estatísticas não Paramétricas
3.
Clin Radiol ; 66(1): 1-12, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21147293

RESUMO

Patent vascular access is a prerequisite for adequate haemodialysis, and is a major determinant of quality of life and long-term survival of patients with end-stage renal disease. Autogenous haemodialysis fistulas (AVFs) have demonstrated superior clinical outcome when compared to synthetic grafts, but both types of access remain susceptible to venous stenoses, and consequent thrombotic occlusion. Recent publications have reported primary patency rates of up to 100% following percutaneous de-clotting of AVFs incorporating techniques such as pharmacological thrombolysis, mechanical thrombectomy, and thrombo-aspiration. Endovascular management also provides information regarding the underlying cause of access thrombosis, with option to treat. Consequently, there has been a paradigm shift in the management of fistula thrombosis, with interventional radiology assuming a lead role in initial salvage procedures. This article will attempt to provide the reader with an insight into the multiple radiological techniques that can be employed to salvage a thrombosed AVF based on current published literature.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Falência Renal Crônica/terapia , Radiologia Intervencionista/métodos , Diálise Renal/efeitos adversos , Terapia de Salvação/métodos , Trombose/diagnóstico por imagem , Humanos , Radiografia , Diálise Renal/métodos , Trombectomia/métodos , Terapia Trombolítica/efeitos adversos , Terapia Trombolítica/métodos , Trombose/prevenção & controle , Trombose/cirurgia
4.
Br J Radiol ; 80(958): 778-81, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17959921

RESUMO

The NHS Bowel Cancer Screening Programme is the first nationally coordinated screening programme to be introduced in the UK for 18 years. Currently, the screening algorithm is based upon faecal occult blood testing and colonoscopy for those screenees testing positive. This commentary provides radiologists with an update on the rationale for colorectal cancer screening, explains the organizational structure of the new UK NHS programme, and explores the possible role for radiology in the current and future screening algorithms.


Assuntos
Neoplasias Colorretais/prevenção & controle , Programas de Rastreamento/organização & administração , Idoso , Sulfato de Bário , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Meios de Contraste , Educação Médica Continuada , Enema , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sangue Oculto , Radiologia/educação , Medicina Estatal , Tomografia Computadorizada por Raios X , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...