Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr Sci ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38745428

RESUMO

In the present work, new chiral stationary phase high-performance liquid chromatography (CSP-HPLC) method was established and validated for the quantification of pomalidomide (PMD) enantiomers in human plasma. The chromatographic enantiomeric separation was achieved on a Daicel-CSP, Chiralpack IA 4.6 × 250 mm, 5 µm; because of its advantages of high degree of retention, high resolution capacity, better reproducibility, ability to produce lower back pressure and low degree of tailing. The mobile phase was maintained as methanol: glacial acetic acid (499.50 ml:50 µL). Ultraviolet wavelength for detection was 220 nm. PMD enantiomer-I and enantiomer-II were separated at 8.83 and 15.34 min, respectively. Limit of detection and limit of quantification for each enantiomer and the calibration curve of standard PMD was linear in range between 10-5,000 ng mL-1. The method was validated according to The International Council for Harmonisation of Technical Requirements of Pharmaceuticals for Human Use (ICH(Q2R1)) specific guidelines. We found no interference peak with PMD chromatogram obtained. This is a simple, reliable and specific method for detection and quantification of enantiomer of PMD in human plasma sample.

2.
Chirality ; 35(2): 83-91, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36458987

RESUMO

Lenalidomide (LND) is an analogue of thalidomide that is second generation immunomodulatory drugs (IMiDs). LND contains asymmetric carbon atom and exist R and S enantiomer. S (-) form of enantiomer are considered to be more potent and biologically active in tumor cell. It is available in racemic form for clinical use. The study aims to develop and validate enantiomer separation of LND in human plasma. The chromatographic enantiomeric separation was achieved on a Daicel-CSP, Chiralpack IA 4.6 × 250 mm_5 µm. The mobile phase was constituted in combination of methanol:glacial acetic acid at a concentration of 499.50 ml: 50 µl. UV wavelength detection was 220 nm. The RSD% for all validation parameters was found to be within the acceptable limit. The chiral chromatographic (chiral stationary phase-high-performance liquid chromatography [CSP-HPLC]) method developed and validated for the quantitative estimation of LND enantiomers S (-) and R (+) in human plasma sample is accurate, precise, robust, stable and selective.


Assuntos
Talidomida , Humanos , Lenalidomida , Estereoisomerismo , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes
3.
J Chromatogr Sci ; 61(7): 605-611, 2023 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36214345

RESUMO

A simple, rapid, sensitive and specific gas chromatography-tandem mass spectrometry (GC-MS/MS) method was developed for quantitation of salbutamol in human urine using salbutamol-d3 as the internal standard. The processing of urines samples includes deconjugation with enzymatic hydrolysis, solid phase extraction procedure utilizing XAD2 column and liquid-liquid extraction accompanied by the derivatization by means of MSTFA/IODO-TMS/DTE mixture. The GC column was a HP Ultra-1 (17 m × 0.22 mm × 0.11 µm) used to separate the peak of interest. The data for GC-MS/MS were acquired and processed utilizing GC Labs Solution and Insight GCMS Software. The detection of spectra was performed on TQ 8050. This method included a chromatographic run of 13.67 min and the linearity was found over the concentration range of 250-2000 ng/mL with a regression coefficient (r2) of 0.99. The coefficient of variation for intra and interday assay precision was between 1.85 and 2.85% and the accuracy was between 95.50 and 107.04% for low quality control (QC), medium QC and high QC. The recovery was adequate to reliable detect the analyte at or below the level recommended by the World Anti-Doping Agency i.e., threshold 1000 ng/mL. The limit of detection and limit of quantification were found to be 10 and 100 ng/mL, respectively. The expanded measurement uncertainty (Uexp%) was found to be 8.28%.


Assuntos
Albuterol , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas , Incerteza , Cromatografia Líquida/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...