Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiol ; 79(3): 365-370, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34937673

RESUMO

BACKGROUND: Mechanical and electrical restoration by cardiac resynchronization therapy (CRT) with adaptive pacing algorithm (aCRT) in heart failure patients with a moderately wide (120-149 ms) QRS has not been fully evaluated. The purpose of this study was to investigate the therapeutic effect of aCRT compared with conventional biventricular CRT (BiV-CRT) regardless of QRS morphology. METHODS: Seventeen consecutive patients with a QRS ≥120 ms, regardless of morphology, underwent CRT device implantation with an aCRT pacing algorithm. Propensity score matched analysis was performed to evaluate the impact of aCRT on the improvement in mechanical and electrical parameters after CRT device implantation using historical controls (HC) from the clinical registry of BiV-CRT (START trial). RESULTS: Left ventricular (LV) volume significantly decreased after CRT in all patients in both the aCRT and HC groups. The difference in relative reduction of LV end-systolic volume (LVESV) was not significantly different between the 2 arms. QRS shortening after CRT was significantly greater in the aCRT group than in the BiV-CRT group, and the difference was prominent in patients with a moderately wide QRS (120-149 ms). In patients with a moderately wide QRS, the relative reduction in LVESV [39 (29-47)% vs. 2 (-6-20)%, p = 0.04] and proportion of LV volume responders (90% vs. 38%, p = 0.04) were significantly greater in the aCRT group than in the HC group. The proportion of volume responders was not significantly different in patients with a wide QRS (≥150 ms). CONCLUSIONS: The aCRT algorithm improved electrical and mechanical parameters in patients with a moderately wide QRS, regardless of QRS morphology.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca Sistólica , Insuficiência Cardíaca , Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca Sistólica/terapia , Ventrículos do Coração , Humanos , Resultado do Tratamento
2.
JACC Clin Electrophysiol ; 5(3): 354-363, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30898239

RESUMO

OBJECTIVES: This study sought to determine the feasibility of a novel simplified ablation protocol targeting only the pulmonary vein antrum using the radiofrequency hot-balloon catheter in patients with paroxysmal atrial fibrillation. BACKGROUND: Radiofrequency hot-balloon (RHB) catheter has been recently introduced into clinical practice for pulmonary vein isolation (PVI). The authors hypothesized that a novel simplified ablation protocol targeting only the PV antrum with energy application for a longer time (single-shot technique) could be an alternative approach to achieve PVI, while avoiding unnecessary energy application at the PV ostium. METHODS: A total of 61 consecutive paroxysmal atrial fibrillation patients (age 64.1 ± 10.9 years, 48 male) who underwent antrum RHB-PVI were enrolled. Energy applications were performed following the pre-specified protocol only targeting the PV antrum. If the PVI was not achieved after 2 energy applications using the RHB, a touch-up ablation was performed. RESULTS: Of 241 PV, including 3 left common PV, 194 (80%) were isolated exclusively using the RHB. The target PVI average per group of 15 consecutive procedures improved from 75% (initial 15) to 89% (last 16) of patients. The injected volume was greatest in the right superior PV (13.1 ± 2.0 ml) and the smallest in the left inferior PV (10.8 ± 1.1 ml), and 23 PV (9.5%) required over 15 ml (estimated balloon diameter of 30 mm). Periprocedural complications were noted in 3 patients (4.9%), but phrenic nerve injury was not observed. Sinus rhythm maintenance at 12-month follow-up was achieved in 57 patients (93%). CONCLUSIONS: A novel simplified antrum RHB-PVI appears to be a feasible technique for the treatment of paroxysmal atrial fibrillation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Idoso , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
Circ Arrhythm Electrophysiol ; 11(8): e005631, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354308

RESUMO

Background Both endocardial trigger elimination and epicardial substrate modification are effective in treating ventricular fibrillation (VF) in Brugada syndrome. However, the primary approach and the characteristics of patients who respond to endocardial ablation remain unknown. Methods Among 123 symptomatic Brugada syndrome patients (VF, 63%; syncope, 37%), ablation was performed in 21 VF/electrical storm patients, the majority of whom were resistant to antiarrhythmic drugs. Results Careful endocardial mapping revealed that 81% of the patients had no specific findings, whereas 19% of the patients, who experienced the most frequent VF episodes with notching of the QRS in lead V1, had delayed low-voltage fractionated endocardial electrograms. Ablation of VF triggers followed by endocardial substrate modification was performed in the right ventricular outflow tract in 85% of the cases and in the right ventricle in 15%. VF triggers could not be completely eliminated in 1 patient and VF became noninducible in 14 (88%) patients among 16 patients who underwent VF induction with normalization of Brugada-type ECG in 3. During follow-up (56.14±36.95 months), VF recurrence was observed in 7 patients. Importantly, all patients who had nothing of QRS in lead V1 did not respond to endocardial ablation despite presence of VF-triggering ectopic beats during ablation. Conclusions With careful documentation of VF-triggering ectopic beats and detailed endocardial mapping, endocardial VF trigger elimination followed by endocardial substrate modification has an excellent long-term outcome, whereas presence of QRS notching in lead V1 was associated with high VF recurrence suggesting epicardial substrate ablation as effective initial approach.


Assuntos
Síndrome de Brugada/complicações , Ablação por Cateter/métodos , Endocárdio/cirurgia , Frequência Cardíaca , Fibrilação Ventricular/cirurgia , Potenciais de Ação , Adulto , Antiarrítmicos/uso terapêutico , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Ablação por Cateter/efeitos adversos , Resistência a Medicamentos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/fisiopatologia , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...