1.
Nanoscale Res Lett ; 11(1): 105, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26911569

RESUMO

The conductometric sensor based on 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 was developed for the quantitative analysis of ammonium. The calixarene was immobilized on the surface of the planar interdigitated electrodes by attachment of its dialkyl sulfide groups to the surface of the gold electrodes. The intrinsic ability of the calixarene to capture ammonium was studied in the conductometric measuring mode and by the electrochemical impedance spectroscopy. The developed sensor showed high selectivity to ammonium in the presence of mono-, di-, and trivalent cations. Selective and highly sensitive detection of ammonium resulted from the complexation between the ammonium ions and a crown-ether fragment of the upper rim of the 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 macrocycle. The developed sensor had high signal repeatability. Its sensitivity was found to be satisfactory for the forthcoming sensor application in the water-sample analysis; the linear range was 0.01-1.5 mM and limit of detection 10 µM.

2.
Talanta ; 121: 18-23, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24607104

RESUMO

In this work a novel biosensor for arginine determination based on the urease inhibition effect has been proposed. Ion-selective field effect transistors were used as transducers. Urease immobilized in glutaraldehyde vapor served as a biorecognition element of the biosensor. Significant part of the work was aimed at proving the urease inhibition by arginine. Optimal concentration of urea for arginine determination was chosen. Detection limit for arginine was 0.05 mM. The biosensor selectivity towards different amino acids was studied. The results of quantitative determination of l-arginine in the real sample (a drinkable solution "Arginine Veyron") were in good agreement with the producer's data (a relative error was 5.2%). The biosensor showed a good reproducibility of arginine determination.


Assuntos
Arginina/análise , Técnicas Biossensoriais , Urease/química , Animais , Bovinos , Limite de Detecção
3.
Talanta ; 115: 200-7, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24054580

RESUMO

The aim of this work was to develop an array of biosensors for simultaneous determination of four carbohydrates in solution. Several enzyme systems selective to lactose, maltose, sucrose and glucose were immobilised on the surface of four conductometric transducers and served as bio-recognition elements of the biosensor array. Direct enzyme analysis carried out by the developed biosensors was highly sensitive to the corresponding substrates. The analysis lasted 2 min. The dynamic range of substrate determination extended from 0.001 mM to 1.0-3.0mM, and strongly depended on the enzyme system used. An effect of the solution pH, ionic strength and buffer capacity on the biosensors responses was investigated; the conditions of simultaneous operation of all biosensors were optimised. The data on cross-impact of the substrates of all biosensors were obtained; the biosensor selectivity towards possible interfering carbohydrates was tested. The developed biosensor array showed good signal reproducibility and storage stability. The biosensor array is suited for simultaneous, quick, simple, and selective determination of maltose, lactose, sucrose and glucose.


Assuntos
Técnicas Biossensoriais/instrumentação , Condutometria/métodos , Glucose/análise , Lactose/análise , Maltose/análise , Sacarose/análise , Calibragem , Condutometria/instrumentação , Enzimas Imobilizadas/química , Concentração de Íons de Hidrogênio , Concentração Osmolar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soluções , Transdutores , Água
4.
Talanta ; 92: 58-64, 2012 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-22385808

RESUMO

A highly sensitive conductometric biosensor for l-arginine determination was developed by exploiting the unique biorecognition capacities of two enzymes of urea cycle - arginase (E.C. 3.5.3.1) and urease (E.C. 3.5.1.5). The enzymes were co-immobilized in a single bioselective membrane on the working sensor, while a lysine rich bovine serum albumin (BSA) membrane was immobilized on the reference sensor, allowing differential measurements. The optimum percentage ratio of arginase and urease within the bioselective membrane was determined when the biosensor sensitivity to l-arginine and urea was optimum. Analytical characteristics of the conductometric biosensor for l-arginine determination were compared for two types of enzyme immobilization (cross-linking with glutaraldehyde (GA) and entrapment in the polymeric membrane). The optimum features in terms of the sensitivity, the linear range, and the detection limit (4.2 µS/mM, 0.01-4mM, and 5.0 × 10(-7)M, respectively) were found for l-arginine biosensor based on enzyme cross-linking with GA. A quantitative determination of l-arginine in the real sample (a drinkable solution "Arginine Veyron") gave a satisfactory result compared to the data provided by the producer (a relative error was 4.6%). The developed biosensor showed high operational and storage stability.


Assuntos
Arginase/química , Arginina/análise , Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/química , Urease/química , Animais , Técnicas Biossensoriais/instrumentação , Bovinos , Condutometria , Reagentes de Ligações Cruzadas/química , Eletrodos , Glutaral/química , Concentração de Íons de Hidrogênio , Limite de Detecção , Membranas Artificiais , Soroalbumina Bovina/química