Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Sci Rep ; 14(1): 6479, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38499650

RESUMO

Intradialytic hypotension (IDH) is a common complication during hemodialysis that increases cardiovascular morbidity and mortality. Aortic stenosis (AS) is a cause of IDH. Transcatheter aortic valve replacement (TAVR) has become an established treatment for patients with severe AS. However, whether TAVR reduce the frequency of IDH has not been investigated. This study aims to verify the efficacy of TAVR for reduction of the frequency of IDH. Consecutive hemodialysis patients who underwent TAVR at Sendai Kosei Hospital from February 2021 to November 2021 with available records 1 month before and 3 months after TAVR were included in the study. IDH was defined as a decrease in systolic blood pressure by 20 mmHg or a decrease in the mean blood pressure by 10 mmHg associated with hypotensive symptoms or requiring intervention. Patients with ≥ 3 episodes of IDH in ten hemodialysis sessions comprised the IDH group. Overall, 18/41 (43.9%) patients were classified into the IDH group. In ten hemodialysis sessions, IDH events were observed 2.1, 4.3, and 0.4 times in the overall cohort, IDH group, and non-IDH group, respectively. After TAVR, the incidence of IDH decreased from 43.2 to 10.3% (p < 0.0001) and IDH improved significantly in 15 patients in the IDH group. The result suggested that severe AS was the major cause of IDH in this cohort, and TAVR may be an effective treatment option for reduction of the frequency of IDH in patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Hipotensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Diálise Renal/efeitos adversos , Hipotensão/etiologia , Hipotensão/cirurgia , Fatores de Risco
4.
J Cardiol ; 81(1): 97-104, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36114119

RESUMO

BACKGROUND: Coronary obstruction is a rare but catastrophic complication of transcatheter aortic valve replacement (TAVR) and occurs mostly at the left coronary artery (LCA) ostium. However, some patients do not show any clinical findings, and thus, its detection is sometimes difficult. The peak diastolic flow velocity in left main coronary artery (LM) was reportedly increased in significant stenosis lesions. We evaluated the effectiveness of measuring blood flow velocities in LM by transesophageal echocardiography (TEE) for the detection of LCA ostial obstruction during a TAVR procedure. METHODS: A total of 1105 consecutive patients who underwent TAVR in Sendai Kousei Hospital between September 2014 and December 2020 were enrolled. The LM blood flow velocity was measured at pre- and post-valve implantation. RESULTS: Among the 1105 patients, 9 had LCA ostial obstruction. The peak LM blood flow velocity at post-TAVR [0.90 (0.39-1.15) vs. 0.37 (0.28-0.50) m/s; p = 0.0046) was significantly higher in 9 patients who had LCA ostial obstruction, compared with the remaining 1096 patients who had not (controls), although no significant difference was observed before the TAVR procedures between the two groups. The post- to pre-TAVR LM flow velocity ratio [2.26 (1.31-3.42) vs. 1.06 (0.82-1.36); p = 0.0030] was also significantly higher in patients with LCA obstruction, compared to the controls. Furthermore, the post- to pre-TAVR LM blood flow velocity ratio was >2.0 in all six hemodynamically stable patients with LCA obstruction, whereas <2.0 in all three patients with LCA obstruction who showed hemodynamic collapse at post-TAVR procedure. CONCLUSION: Coronary blood flow velocity in LM significantly increased in hemodynamically stable LCA obstruction patients. The intraprocedural TEE measurement of the LM flow velocities would be potentially useful to detect asymptomatic and hemodynamically stable LCA ostial obstruction.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Ecocardiografia Transesofagiana , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Oclusão Coronária/cirurgia , Ecocardiografia , Resultado do Tratamento , Valva Aórtica/cirurgia
5.
J Cardiol ; 80(3): 190-196, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35469714

RESUMO

BACKGROUND: In transcatheter aortic valve replacement (TAVR) using SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, CA, USA), some clinicians decrease or increase the delivery balloon volume (VOL) when deploying S3 or conducting post-dilatation. However, the effects of controlling VOL on transcatheter heart valve diameter (THVD) and valve function remain unclear. We assessed associations among VOL, THVD, and effective orifice area (EOA) of S3. METHODS: We enrolled patients undergoing TAVR using 23- and 26-mm S3 in Sendai Kousei Hospital between 2017 and 2019. VOL was controlled based on preprocedural computed tomography and intraprocedural transesophageal echocardiography (TEE). THVD were defined as the diameters of transcatheter heart valve at mid-level measured by TEE. RESULTS: In enrolled 332 patients (23-mm, n = 188; 26-mm, n = 144), one (0.3%) and two (0.6%) developed annulus rupture and moderate/severe paravalvular leak, respectively. VOL at deployment was positively correlated with THVD on deployment (23-mm, r = 0.44, p < 0.001; 26-mm, r = 0.57, p < 0.001) and EOA (23-mm, r = 0.23, p = 0.0019; 26-mm, r = 0.22, p = 0.0094). In multiple regression analyses, VOL and post-dilatation were significant determinants of THVD, although aortic annulus area, calcium volume, and pre-dilatation were not. The areas under the receiver operating characteristic curve that were used to evaluate the accuracy of the index obtained by dividing THVD by body surface area (indexed THVD) to predict patient-prosthesis mismatch (PPM) were 0.744 and 0.811 in the 23- and 26-mm cohorts, respectively. A cut-off indexed THVD of ≤11.5 and 12.1 mm/m2 well predicted PPM (23-mm, odds ratio, 5.20; 95% confidence interval, 1.33-20.3; 26-mm, odds ratio 14.1, 95% confidence interval 2.40-81.0). CONCLUSION: VOL was positively correlated with THVD and EOA. Smaller indexed THVD was associated with a higher incidence of PPM. Controlling VOL under on-site THVD evaluation may be useful in reducing the PPM incidence.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
Eur Heart J Case Rep ; 6(2): ytac059, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35233498

RESUMO

BACKGROUND: Coronary access after transcatheter aortic valve implantation (TAVI) is challenging due to the changes in aortic geometry. The perpendicular (long-axis) view of the transcatheter heart valve (THV) is usually used as the primary fluoroscopic angle. However, it does not always provide sufficient information on the rotational axis needed for selective coronary ostia engagement. The en face (short-axis) view from the deep right-anterior-oblique cranial position gives us additional information about three-dimensional spatial relationship of the THV and coronary ostia. CASE SUMMARY: We present three cases of coronary access after TAVI. We were successful in the use of the 'en face' view along with the perpendicular view in these cases. DISCUSSION: The use of the en face view complements that of the perpendicular long-axis view since it allows the understanding of the three-dimensional spatial relationship of the THV and the coronary ostia during fluoroscopy and control of catheter manipulation in two directions (up/down for perpendicular and clockwise/counterclockwise for en face view). We believe that the en face view helps improve the technical success of coronary access after TAVI.

7.
Case Rep Vasc Med ; 2021: 6687450, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33777474

RESUMO

Recurrent varices after surgery (REVAS) is a common problem with no established treatment. Ultrasonography is a hard method to identify the source of veins that cause REVAS, especially in obese patients with thick thighs. Here, we report the case of a 64-year-old obese patient who previously underwent endothermal venous ablation for her right great saphenous vein. The patient presented with right leg swelling and venous ulceration due to REVAS. Although the source of REVAS was unclear because the patient had thick thighs on ultrasonography assessment, venography revealed that the source of REVAS was the incompetent perforator vein (IPV). Selective ablation for the IPV with radiofrequency ablation catheter was performed. We could ablate the target veins selectively so as not to ablate within the deep vein. The patient remains asymptomatic for 2 years after the procedure, and there has been no recurrence of her varicose veins. Venography allows better visualization of the source of REVAS than ultrasonography. With selective ablation, it is especially effective procedure in obese patients, in whom it is difficult to identify and access the source of REVAS with ultrasonography.

8.
Ann Vasc Dis ; 13(2): 194-197, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32595800

RESUMO

Iliac vein compression syndrome (IVCS) can occasionally be iatrogenic; however, iatrogenic IVCS cases occurring because of inappropriate length and positioning of vascular grafts have not been reported. We present the case of an 80-year-old woman with iatrogenic IVCS resulting from kinked and overlapping limbs of a bifurcated abdominal vascular prosthesis for an abdominal aortic aneurysm. She complained of discomfort in her left leg immediately after aortic replacement. Venous stenting was effective for IVCS occurring because of compression of the vascular prosthesis. Iatrogenic IVCS occurred because of inappropriate length and positioning of the vascular graft and was considered a postoperative complication.

9.
Thromb J ; 15: 10, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28396618

RESUMO

BACKGROUND: Saphenous vein graft thrombosis can present as unstable angina. However, percutaneous coronary intervention for saphenous vein graft lesions poses a high risk of slow flow related to the procedure. Here we present the utilization of the novel oral anticoagulant, apixaban, in the treatment of unstable angina with extensive saphenous vein graft thrombus, leading to considerable thrombus resolution and eliminating the need of percutaneous coronary intervention. CASE PRESENTATION: A 72-year-old man with 3-vessel coronary artery bypass graft surgery using a saphenous vein graft and a left internal mammary artery, performed 25 years earlier, presented at our hospital with recurrent chest tightness. The echocardiography showed regional hypokinesis of the post-lateral wall with moderate left ventricular dysfunction, which had not been previously confirmed. Coronary angiography showed obstruction of the saphenous vein graft with a large thrombus burden. The left internal mammary artery was patent and other natives were the same as they had been 3 years ago. He was diagnosed with unstable angina due to acute saphenous vein graft thrombosis. Instead of percutaneous coronary intervention, he was treated with apixaban 5 mg twice a day. The angiography 3 weeks after starting apixaban showed considerable resolution of the thrombus and opening of the saphenous vein graft. CONCLUSIONS: Apixaban could become a viable treatment option for acute saphenous vein graft thrombosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA