Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 35(6): 619-623, 2019 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-30713219

RESUMO

Two types of metal mesh devices with hole diameters of 1.7 and 0.3 µm were prepared by an electroforming method. The metal mesh devices with hole diameters of 1.7 and 0.3 µm transmitted electromagnetic waves with frequencies of approximately 100 and 285 THz, respectively. These spectral frequencies shifted depending on the adsorption amount of protein. The slope in the linear relationship between the adsorption amount and spectral shift (i.e. sensitivity) of the metal mesh device with a hole diameter of 0.3 µm was seven times as great as that of the device with a hole diameter of 1.7 µm. These results agreed with the theoretical concept of the sensitivity for the metal mesh device sensor being proportional to the square of the transmittance frequency. As biosensors, the structurally refined metal mesh devices amplified the output signals.

2.
Microsc Res Tech ; 81(7): 761-769, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29675989

RESUMO

Green culms of Bambusa multiplex and the bamboo charcoal carbonized from the green culms at 700°C have been studied by means of X-ray diffraction, X-ray fluorescent element analysis, analytical scanning electron microscopy, and analytical scanning transmission electron microscopy (STEM), aiming at industrial applications as raw materials for functional devices and substances. It is revealed that the green culms and the charcoal contain a significant amount of Si, in particular, ∼18 wt % in the skin. The green culms comprise amorphous and crystalline celluloses. The charcoal has a so-called amorphous structure which is composed of randomly distributed carbon nanotubes and fibers. The growth of Ag-doped activated charcoal powders that were produced by two different methods using this charcoal powder has also been studied.


Assuntos
Bambusa/química , Carvão Vegetal/química , Caules de Planta/química , Bambusa/ultraestrutura , Celulose/química , Cor , Microscopia Eletrônica de Varredura , Nanotubos de Carbono , Caules de Planta/ultraestrutura , Difração de Raios X
3.
Circ J ; 71(9): 1458-62, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17721028

RESUMO

BACKGROUND: Although measurement of serum creatine kinase levels, as well as myoglobin levels, has been used for screening patients with acute coronary syndrome (ACS), the specificity of both is low. Measurement of cardiac troponin levels is now extensively used for the diagnosis of ACS because of their superior cardiac specificity. However, troponin levels are reportedly elevated not only in patients with ACS but also in those with other diseases. METHODS AND RESULTS: The clinical characteristics of 1,023 patients (mean age: 63.5+/-16.3 years; males: 665, females: 358) whose serum cardiac troponin I (cTnI) levels had been measured at the initial visit to the emergency room of Toyota Memorial Hospital between April 2004 and March 2005 were retrospectively analyzed. A positive elevation of cTnI was defined as cTnI > or =0.03 ng/ml. There were 432 patients (42.2%) with positive cTnI levels. The cTnI levels (8.48+/-2.64 ng/ml) in patients with acute myocardial infarction (AMI) were greater than those (0.25+/-0.07 ng/ml) in patients with unstable angina pectoris (AP), as well as those (0.04+/-0.01 ng/ml) in patients with stable AP. In terms of the diagnosis of AMI, the sensitivity was high enough (94.6%), but its specificity was relatively low (61.9%). Furthermore, the differentiation between AMI and unstable AP by the cTnI value alone was impossible. The cTnI levels were elevated in patients with a variety of diseases other than ACS, including heart failure, cardiomyopathies, myocarditis, renal failure, tachyarrhythmias, and pulmonary embolism. CONCLUSIONS: Elevation of the cTnI level is frequently observed in patients in the emergency room with common diseases other than ACS.


Assuntos
Síndrome Coronariana Aguda/sangue , Serviço Hospitalar de Emergência , Miocárdio/metabolismo , Troponina I/sangue , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/sangue , Cardiomiopatias/diagnóstico , Cardiomiopatias/patologia , Creatina Quinase/sangue , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/sangue , Miocardite/diagnóstico , Miocardite/patologia , Miocárdio/patologia , Mioglobina/sangue , Valor Preditivo dos Testes , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/patologia , Insuficiência Renal/sangue , Insuficiência Renal/diagnóstico , Insuficiência Renal/patologia , Estudos Retrospectivos , Taquicardia/sangue , Taquicardia/diagnóstico , Taquicardia/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA