Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Am J Hosp Palliat Care ; : 10499091241226606, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195411

RESUMO

OBJECTIVE: Palliative care consultation is relevant for patients requiring Venous-Arterial Extracorporeal Membrane Oxygenation (VA-ECMO); however, evidence is limited to support its value. For this population, we compared length of stay (LOS) (primary outcome), operational metrics and goals of care (GOC) frequency before and after a collaboration between cardiothoracic (CT) surgery and Geriatrics and Palliative Medicine (GaP). METHODS: Retrospective chart review of patients (18+) admitted to a quaternary center that required VA-ECMO between 2019-2021 and received GaP consultation. Demographics, LOS, times to consult, illness severity, GOC, and outcomes were analyzed. RESULTS: 120 patients met inclusion criteria and 64 (53.3%) had GaP consultation. No differences were observed regarding demographics and insertion status (emergent vs elective). Median (IQR) days to GaP consult for 2019, 2020 and 2021 were 6.5 (4.0-14.5), 5.0 (2.0-11.0) and 3.0 (2.0-5.0), respectively (P = .006). Median days from insertion to consult for 2019, 2020 and 2021 were 6.0 (4.0-20.0), 3.0 (1.0-6.0) and 2.0 (1.0-4.0) (P = .003). Among survivors, over the 3-year course, median LOS was not statistically different. Between expired patients, median (IQR) LOS for 2019, 2020, and 2021 was 28.5 (23.0-40.0), 12.0 (8.0-14.0), 11.0 (5.0-17.0) days (P = .013). For patients not seen by GaP, 8 (14.3%) GOC notes were documented, compared with 42 (65.6%) for patients seen. Mortality was similar (53.6% vs 53.1% [GaP]). CONCLUSION: For patient on VA-ECMO, early GaP consultation may improve hospital LOS and GOC rates. We suggest organizations consider early palliative integration when instituting mechanical circulatory support.

2.
Front Cardiovasc Med ; 10: 1206570, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028504

RESUMO

Background: Expert opinion and professional society statements have called for multi-tier care systems for the management of cardiogenic shock (CS). However, little is known about how to pragmatically define centers with different levels of care (LOC) for CS. Methods: Eleven of 23 hospitals within our healthcare system sharing a common electronic health record were classified as different LOC according to their highest mechanical circulatory support (MCS) capabilities: Level 1 (L-1)-durable left ventricular assist device, Level 1A (L-1A)-extracorporeal membrane oxygenation, Level 2 (L-2)-intra-aortic balloon pump and percutaneous ventricular assist device; and Level 3 (L-3)-no MCS. All adult patients treated for CS (International Classification of Diseases, ICD-10 code R57.0) between 2016 and 2022 were included. Etiologies of CS were identified using associated diagnostic codes. Management strategies and outcomes across LOC were compared. Results: Higher LOC centers had higher volumes: L-1 (n = 1): 2,831 patients, L-1A (n = 4): 3,452, L-2 (n = 1): 340, and L-3 (n = 5): 780. Emergency room admissions were more common in lower LOC (96% at L-3 vs. 46% L-1; p < 0.001), while hospital transfers were predominant at higher LOC (40% at L-1 vs. 2.7% at L-3; p < 0.001). Men comprised 61% of the cohort. Patients were younger in the higher LOC [69 (60-78) years at L-1 vs. 77 (67-85) years at L-3; p < 0.001]. Patients with acute myocardial infarction (AMI)-CS and acute heart failure (AHF)-CS were concentrated in higher LOC centers while other etiologies of CS were more common in L-2 and L-3 (p < 0.001). Cardiac arrest on admission was more prevalent in lower LOC centers (L-1: 2.8% vs. L-3: 12.1%; p < 0.001). Patients with AMI-CS received more percutaneous coronary intervention in lower LOC (51% L-2 vs. 29% L-1; p < 0.01) but more coronary arterial bypass graft surgery at higher LOC (L-1: 42% vs. L-1A: 23%; p < 0.001). MCS use was consistent across levels for AMI-CS but was more frequent in higher LOC for AHF-CS patients (L-1: 28% vs. L-2: 10%; p < 0.001). Despite increasing in-hospital mortality with decreasing LOC, no significant difference was seen after multivariable adjustment. Conclusion: This is the first report describing a pragmatic classification of LOC for CS which, based on MCS capabilities, can discriminate between centers with distinct demographics, practice patterns, and outcomes. This classification may serve as the basis for future research and the creation of CS systems of care.

3.
Indian J Thorac Cardiovasc Surg ; : 1-11, 2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36820202

RESUMO

Recent advances in veno-arterial (VA) and veno-venous (VV) extracorporeal membrane oxygenation (ECMO) technology and management have enabled us to support patients with cardiac and/or pulmonary failure, who may have previously been considered untreatable. VA ECMO and VV ECMO are by definition transient therapies and serve as a bridge to recovery, bridge to decision, bridge to transplant, or bridge to no recovery. Weaning ECMO should be considered for all patients once native cardiac and pulmonary function show signs of recovery. Currently, there are no universally accepted protocols for weaning VA and VV ECMO, and consequently, each individual center follows their own weaning protocols. The aim of this review article is to describe different approaches to safely wean from VA and VV ECMO.

4.
J Cardiothorac Vasc Anesth ; 35(12): 3735-3742, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33388220

RESUMO

Temporary left ventricular support aims to decompress the left ventricle and provide adequate forward flow into the arterial circulation. This can be accomplished with endovascular devices such as the Impella with an internal motor, or with the implementation of cannulae to drain the left ventricle or left atrium and then return to the arterial circulation using an external pump. In this report, the authors describe the transesophageal echocardiography-guided placement of a single-cannula system with the Protek Duo RD (TandemLife, LivaNova) via a left ventricular apical approach to provide minimally invasive left ventricular support in a high-risk Jehovah's Witness patient.


Assuntos
Coração Auxiliar , Testemunhas de Jeová , Cânula , Ecocardiografia Transesofagiana , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos
6.
J Cardiovasc Magn Reson ; 15: 61, 2013 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-23870697

RESUMO

BACKGROUND: Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance. METHODS AND RESULTS: We used real-time CMR to guide subxiphoid pericardial access in naïve swine using commercial 18G titanium puncture needles, which were exchanged for pericardial catheters. To test the value of CMR needle pericardiocentesis, we also created intentional pericardial effusions of a range of volumes, via a separate transvenous-transatrial catheter. We performed these procedures in 12 animals. CONCLUSIONS: CMR guided pericardiocentesis is attractive because the large field of view and soft tissue imaging depict global anatomic context in arbitrary planes, and allow the operator to plan trajectories that limit inadvertent bystander tissue injury. More important, CMR provides continuous visualization of the needle and target throughout the procedure. Using even passive needle devices, CMR enabled rapid pericardial needle access and drainage. We believe this experience supports clinical testing of real-time CMR guided needle access or drainage of the pericardial space. We suspect this would be especially helpful in "difficult" pericardial access, for example, in distorted thoracic anatomy or loculated effusion.


Assuntos
Catéteres , Imagem por Ressonância Magnética Intervencionista , Derrame Pericárdico/terapia , Pericardiocentese/instrumentação , Pericardiocentese/métodos , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Hemodinâmica , Agulhas , Derrame Pericárdico/fisiopatologia , Pericardiocentese/efeitos adversos , Punções , Suínos , Fatores de Tempo
7.
J Magn Reson Imaging ; 36(4): 972-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22707441

RESUMO

PURPOSE: To develop an active delivery system that enhances visualization of nitinol cardiac occluder devices during deployment under real-time magnetic resonance imaging (MRI). MATERIALS AND METHODS: We constructed an active delivery cable incorporating a loopless antenna and a custom titanium microscrew to secure the occluder devices. The delivery cable was tuned and matched to 50Ω at 64 MHz with the occluder device attached. We used real-time balanced steady state free precession in a wide-bore 1.5T scanner. Device-related images were reconstructed separately and combined with surface-coil images. The delivery cable was tested in vitro in a phantom and in vivo in swine using a variety of nitinol cardiac occluder devices. RESULTS: In vitro, the active delivery cable provided little signal when the occluder device was detached and maximal signal with the device attached. In vivo, signal from the active delivery cable enabled clear visualization of occluder device during positioning and deployment. Device release resulted in decreased signal from the active cable. Postmortem examination confirmed proper device placement. CONCLUSION: The active delivery cable enhanced the MRI depiction of nitinol cardiac occluder devices during positioning and deployment, both in conventional and novel applications. We expect enhanced visibility to contribute to the effectiveness and safety of new and emerging MRI-guided treatments.


Assuntos
Ligas , Imagem por Ressonância Magnética Intervencionista/instrumentação , Implantação de Prótese/instrumentação , Dispositivo para Oclusão Septal , Telemetria/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Suínos
8.
J Cardiovasc Magn Reson ; 14: 38, 2012 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-22720758

RESUMO

BACKGROUND: The field of interventional cardiovascular MRI is hampered by the unavailability of active guidewires that are both safe and conspicuous. Heating of conductive guidewires is difficult to predict in vivo and disruptive to measure using external probes. We describe a clinical-grade 0.035" (0.89 mm) guidewire for MRI right and left heart catheterization at 1.5 T that has an internal probe to monitor temperature in real-time, and that has both tip and shaft visibility as well as suitable flexibility. METHODS: The design has an internal fiberoptic temperature probe, as well as a distal solenoid to enhance tip visibility on a loopless antenna. We tested different tip-solenoid configurations to balance heating and signal profiles. We tested mechanical performance in vitro and in vivo in comparison with a popular clinical nitinol guidewire. RESULTS: The solenoid displaced the point of maximal heating ("hot spot") from the tip to a more proximal location where it can be measured without impairing guidewire flexion. Probe pullback allowed creation of lengthwise guidewire temperature maps that allowed rapid evaluation of design prototypes. Distal-only solenoid attachment offered the best compromise between tip visibility and heating among design candidates. When fixed at the hot spot, the internal probe consistently reflected the maximum temperature compared external probes.Real-time temperature monitoring was performed during porcine left heart catheterization. Heating was negligible using normal operating parameters (flip angle, 45°; SAR, 1.01 W/kg); the temperature increased by 4.2°C only during high RF power mode (flip angle, 90°; SAR, 3.96 W/kg) and only when the guidewire was isolated from blood cooling effects by an introducer sheath. The tip flexibility and in vivo performance of the final guidewire design were similar to a popular commercial guidewire. CONCLUSIONS: We integrated a fiberoptic temperature probe inside a 0.035" MRI guidewire. Real-time monitoring helps detect deleterious heating during use, without impairing mechanical guidewire operation, and without impairing MRI visibility. We therefore need not rely on prediction to ensure safe clinical operation. Future implementations may modulate specific absorption rate (SAR) based on temperature feedback.


Assuntos
Ligas , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Cardiopatias/diagnóstico , Imagem Cinética por Ressonância Magnética/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Fibras Ópticas , Maleabilidade , Suínos , Temperatura
9.
J Magn Reson Imaging ; 35(4): 908-15, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22128071

RESUMO

PURPOSE: To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. MATERIALS AND METHODS: The catheter shaft incorporated Kevlar braiding. A 180° deflection was attained with a 5-cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. RESULTS: Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. CONCLUSION: Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057" lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Coração/anatomia & histologia , Imagem por Ressonância Magnética Intervencionista/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
10.
JACC Cardiovasc Interv ; 4(12): 1318-25, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22192372

RESUMO

OBJECTIVES: This study sought to evaluate feasibility of nonsurgical transthoracic catheter-based left ventricular (LV) access and closure. BACKGROUND: Implanting large devices, such as mitral or aortic valve prostheses, into the heart requires surgical exposure and repair. Reliable percutaneous direct transthoracic LV access and closure would allow new nonsurgical therapeutic procedures. METHODS: Percutaneous direct LV access was performed in 19 swine using real-time magnetic resonance imaging (MRI) and an "active" MRI needle antenna to deliver an 18-F introducer sheath. The LV access ports were closed percutaneously using a commercial ventricular septal defect occluder and an "active" MRI delivery cable for enhanced visibility. We used "permissive pericardial tamponade" (temporary fluid instillation to separate the 2 pericardial layers) to avoid pericardial entrapment by the epicardial disk. Techniques were developed in 8 animals, and 11 more were followed up to 3 months by MRI and histopathology. RESULTS: Imaging guidance allowed 18-F sheath access and closure with appropriate positioning of the occluder inside the transmyocardial tunnel. Of the survival cohort, immediate hemostasis was achieved in 8 of 11 patients. Failure modes included pericardial entrapment by the epicardial occluder disk (n = 2) and a true-apex entry site that prevented hemostatic apposition of the endocardial disk (n = 1). Reactive pericardial effusion (192 ± 118 ml) accumulated 5 ± 1 days after the procedure, requiring 1-time drainage. At 3 months, LV function was preserved, and the device was endothelialized. CONCLUSIONS: Direct percutaneous LV access and closure is feasible using real-time MRI. A commercial occluder achieved hemostasis without evident deleterious effects on the LV. Having established the concept, further clinical development of this approach appears realistic.


Assuntos
Cateterismo Cardíaco/métodos , Ventrículos do Coração , Animais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Tamponamento Cardíaco/etiologia , Catéteres , Angiografia Coronária/métodos , Desenho de Equipamento , Estudos de Viabilidade , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Imagem por Ressonância Magnética Intervencionista , Modelos Animais , Derrame Pericárdico/etiologia , Desenho de Prótese , Dispositivo para Oclusão Septal , Volume Sistólico , Suínos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda
11.
JACC Cardiovasc Interv ; 4(12): 1326-34, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22192373

RESUMO

OBJECTIVES: The aim of this study was to close ventricular septal defects (VSDs) directly through the chest wall using magnetic resonance imaging (MRI) guidance, without cardiopulmonary bypass, sternotomy, or radiation exposure. BACKGROUND: Surgical, percutaneous, and hybrid management of VSD each have limitations and known morbidity. METHODS: Percutaneous muscular VSDs were created in 10 naive Yorkshire swine using a transjugular laser catheter. Under real-time MRI guidance, a direct transthoracic vascular access sheath was introduced through the chest into the heart along a trajectory suitable for VSD access and closure. Through this transthoracic sheath, muscular VSDs were occluded using a commercial nitinol device. Finally, the right ventricular free wall was closed using a commercial collagen plug intended for arterial closure. RESULTS: Anterior, posterior, and mid-muscular VSDs (6.8 ± 1.8 mm) were created. VSDs were closed successfully in all animals. The transthoracic access sheath was displaced in 2, both fatal. Thereafter, we tested an intracameral retention sheath to prevent this complication. Right ventricular access ports were closed successfully in all, and after as many as 30 days, healed successfully. CONCLUSIONS: Real-time MRI guidance allowed closed-chest transthoracic perventricular muscular VSD closure in a clinically meaningful animal model. Once applied to patients, this approach may avoid traditional surgical, percutaneous, or open-chest transcatheter ("hybrid") risks.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular/terapia , Imagem por Ressonância Magnética Intervencionista , Animais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Modelos Animais de Doenças , Comunicação Interventricular/patologia , Desenho de Prótese , Dispositivo para Oclusão Septal , Suínos , Fatores de Tempo
12.
J Magn Reson Imaging ; 34(5): 1159-66, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22006552

RESUMO

PURPOSE: To develop an approach to vascular access under magnetic resonance imaging (MRI), as a component of comprehensive MRI-guided cardiovascular catheterization and intervention. MATERIALS AND METHODS: We attempted jugular vein access in healthy pigs as a model of "difficult" vascular access. Procedures were performed under real-time MRI guidance using reduced field of view imaging. We developed an "active" MRI antenna-needle having an open-lumen, distinct tip appearance and indicators of depth and trajectory in order to enhance MRI visibility during the procedure. We compared performance of the active needle against an unmodified commercial passively visualized needle, measured by procedure success among operators with different levels of experience. RESULTS: MRI-guided central vein access was feasible using both the active needle and the unmodified passive needle. The active needle required less time (88 vs. 244 sec, P = 0.022) and fewer needle passes (4.5 vs. 9.1, P = 0.028), irrespective of operator experience. CONCLUSION: MRI-guided access to central veins is feasible in our animal model. When image guidance is necessary for vascular access, performing this component under MRI will allow wholly MRI-guided catheterization procedures that do not require adjunctive imaging facilities such as x-ray or ultrasound. The active needle design showed enhanced visibility, as expected. These capabilities may permit more complex catheter-based cardiovascular interventional procedures enabled by enhanced image guidance.


Assuntos
Cateterismo Venoso Central/métodos , Diagnóstico por Imagem/métodos , Veias Jugulares/patologia , Imageamento por Ressonância Magnética/métodos , Angiografia/métodos , Animais , Cardiologia/métodos , Cateterismo , Cateterismo Venoso Central/instrumentação , Competência Clínica , Desenho de Equipamento , Agulhas , Reprodutibilidade dos Testes , Suínos
13.
J Magn Reson Imaging ; 33(5): 1184-93, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21509878

RESUMO

PURPOSE: To develop a system for artifact suppression in electrocardiogram (ECG) recordings obtained during interventional real-time magnetic resonance imaging (MRI). MATERIALS AND METHODS: We characterized ECG artifacts due to radiofrequency pulses and gradient switching during MRI in terms of frequency content. A combination of analog filters and digital least mean squares adaptive filters were used to filter the ECG during in vivo experiments and the results were compared with those obtained with simple low-pass filtering. The system performance was evaluated in terms of artifact suppression and ability to identify arrhythmias during real-time MRI. RESULTS: Analog filters were able to suppress artifacts from high-frequency radiofrequency pulses and gradient switching. The remaining pulse artifacts caused by intermittent preparation sequences or spoiler gradients required adaptive filtering because their bandwidth overlapped with that of the ECG. Using analog and adaptive filtering, a mean improvement of 38 dB (n = 11, peak QRS signal to pulse artifact noise) was achieved. This filtering system was successful in removing pulse artifacts that obscured arrhythmias such as premature ventricular complexes and complete atrioventricular block. CONCLUSION: We have developed an online ECG monitoring system employing digital adaptive filters that enables the identification of cardiac arrhythmias during real-time MRI-guided interventions.


Assuntos
Eletrocardiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Animais , Artefatos , Eletrodos , Humanos , Modelos Estatísticos , Física/métodos , Suínos , Fatores de Tempo
14.
Catheter Cardiovasc Interv ; 77(7): 1079-85, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21234923

RESUMO

INTRODUCTION: Closed-chest access and closure of direct cardiac punctures may enable a range of therapeutic procedures. We evaluate the safety and feasibility of closing percutaneous direct ventricular access sites using a commercial collagen-based femoral artery closure device. METHODS: Yorkshire swine underwent percutaneous transthoracic left ventricular access (n = 13). The access port was closed using a commercial collagen-based vascular closure device (Angio-Seal, St. Jude Medical) with or without prior separation of the pericardial layers by instillation of fluid into the pericardial space ("permissive pericardial tamponade"). After initial nonsurvival feasibility experiments (n = 6); animals underwent 1-week (n = 3) or 6-week follow-up (n = 4). RESULTS: In naïve animals, the collagen plug tended to deploy outside the parietal pericardium, where it failed to accomplish hemostasis. "Permissive pericardial tamponade" was created under MRI, and accomplished early hemostasis by allowing the collagen sponge to seat on the epicardial surface inside the pericardium. After successful closure, six of seven animals accumulated a large pericardial effusion 5 ± 1 days after closure. Despite percutaneous drainage during 6-week follow-up, the large pericardial effusion recurred in half, and was lethal in one. CONCLUSIONS: A commercial collagen-based vascular closure device may achieve temporary but not durable hemostasis when closing a direct left ventricular puncture port, but only after intentional pericardial separation. These insights may contribute to development of a superior device solution. Elective clinical application of this device to close apical access ports should be avoided.


Assuntos
Cateterismo Cardíaco , Tamponamento Cardíaco/prevenção & controle , Colágeno/uso terapêutico , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Hemostáticos/uso terapêutico , Animais , Cateterismo Cardíaco/efeitos adversos , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/etiologia , Drenagem , Desenho de Equipamento , Falha de Equipamento , Estudos de Viabilidade , Ventrículos do Coração , Hemorragia/diagnóstico , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Imageamento por Ressonância Magnética , Teste de Materiais , Modelos Animais , Derrame Pericárdico/etiologia , Derrame Pericárdico/prevenção & controle , Punções , Suínos , Fatores de Tempo
15.
Magn Reson Med ; 63(4): 1070-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373408

RESUMO

The accurate visualization of interventional devices is crucial for the safety and effectiveness of MRI-guided interventional procedures. In this paper, we introduce an improvement to the visualization of active devices. The key component is a fast, robust method ("CurveFind") that reconstructs the three-dimensional trajectory of the device from projection images in a fraction of a second. CurveFind is an iterative prediction-correction algorithm that acts on a product of orthogonal projection images. By varying step size and search direction, it is robust to signal inhomogeneities. At the touch of a key, the imaged slice is repositioned to contain the relevant section of the device ("SnapTo"), the curve of the device is plotted in a three-dimensional display, and the point on a target slice, which the device will intersect, is displayed. These features have been incorporated into a real-time MRI system. Experiments in vitro and in vivo (in a pig) have produced successful results using a variety of single- and multichannel devices designed to produce both spatially continuous and discrete signals. CurveFind is typically able to reconstruct the device curve, with an average error of approximately 2 mm, even in the case of complex geometries.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Animais , Biópsia por Agulha/instrumentação , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Suínos , Doenças Vasculares/cirurgia
16.
J Magn Reson Imaging ; 31(4): 1015-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373448

RESUMO

PURPOSE: To enhance real-time magnetic resonance (MR)-guided catheter navigation by overlaying colorized multiphase MR angiography (MRA) and cholangiopancreatography (MRCP) roadmaps in an anatomic context. MATERIALS AND METHODS: Time-resolved MRA and respiratory-gated MRCP were acquired prior to real-time imaging in a pig model. MRA and MRCP data were loaded into a custom real-time MRI reconstruction and visualization workstation where they were displayed as maximum intensity projections (MIPs) in distinct colors. The MIPs were rendered in 3D together with real-time multislice imaging data using alpha blending. Interactive rotation allowed different views of the combined data. RESULTS: Fused display of the previously acquired MIP angiography data with real-time imaging added anatomical context during endovascular interventions in swine. The use of multiple MIPs rendered in different colors facilitated differentiation of vascular structures, improving visual feedback during device navigation. CONCLUSION: Interventional real-time MRI may be enhanced by combining with previously acquired multiphase angiograms. Rendered as 3D MIPs together with 2D slice data, this technique provided useful anatomical context that enhanced MRI-guided interventional applications.


Assuntos
Colangiopancreatografia por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Processamento de Imagem Assistida por Computador/métodos , Pulmão/patologia , Modelos Anatômicos , Suínos , Trombectomia/métodos , Fatores de Tempo
17.
JACC Cardiovasc Imaging ; 2(11): 1321-31, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19909937

RESUMO

Cardiovascular magnetic resonance (CMR) combines excellent soft-tissue contrast, multiplanar views, and dynamic imaging of cardiac function without ionizing radiation exposure. Interventional cardiovascular magnetic resonance (iCMR) leverages these features to enhance conventional interventional procedures or to enable novel ones. Although still awaiting clinical deployment, this young field has tremendous potential. We survey promising clinical applications for iCMR. Next, we discuss the technologies that allow CMR-guided interventions and, finally, what still needs to be done to bring them to the clinic.


Assuntos
Cateterismo Cardíaco/métodos , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/terapia , Cateterismo Periférico/métodos , Imagem por Ressonância Magnética Intervencionista , Adulto , Animais , Cateterismo Cardíaco/instrumentação , Ablação por Cateter/métodos , Cateterismo Periférico/instrumentação , Criança , Meios de Contraste , Desenho de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador , Imagem por Ressonância Magnética Intervencionista/instrumentação , Valor Preditivo dos Testes , Radiografia Intervencionista , Stents , Resultado do Tratamento
18.
J Cardiovasc Magn Reson ; 11: 29, 2009 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-19674464

RESUMO

BACKGROUND: Catheter visualization and tracking remains a challenge in interventional MR.Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. RESULTS: The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2 degrees C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. CONCLUSION: We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.


Assuntos
Ligas , Cateterismo Periférico/instrumentação , Cobre , Imagem por Ressonância Magnética Intervencionista/instrumentação , Polímeros , Animais , Aorta/anatomia & histologia , Desenho de Equipamento , Artéria Femoral/anatomia & histologia , Teste de Materiais , Modelos Animais , Imagens de Fantasmas , Maleabilidade , Artéria Subclávia/anatomia & histologia , Suínos , Temperatura , Torque
19.
J Am Coll Cardiol ; 54(7): 638-51, 2009 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-19660696

RESUMO

OBJECTIVES: We developed and tested a novel transcatheter circumferential annuloplasty technique to reduce mitral regurgitation in porcine ischemic cardiomyopathy. BACKGROUND: Catheter-based annuloplasty for secondary mitral regurgitation exploits the proximity of the coronary sinus to the mitral annulus, but is limited by anatomic variants and coronary artery entrapment. METHODS: The procedure, "cerclage annuloplasty," is guided by magnetic resonance imaging (MRI) roadmaps fused with live X-ray. A coronary sinus guidewire traverses a short segment of the basal septal myocardium to re-enter the right heart where it is exchanged for a suture. Tension is applied interactively during imaging and secured with a locking device. RESULTS: We found 2 feasible suture pathways from the great cardiac vein across the interventricular septum to create cerclage. Right ventricular septal re-entry required shorter fluoroscopy times than right atrial re-entry, which entailed a longer intramyocardial traversal but did not cross the tricuspid valve. Graded tension progressively reduced septal-lateral annular diameter, but not end-systolic elastance or regional myocardial function. A simple arch-like device protected entrapped coronary arteries from compression even during supratherapeutic tension. Cerclage reduced mitral regurgitation fraction (from 22.8 +/- 12.7% to 7.2 +/- 4.4%, p = 0.04) by slice tracking velocity-encoded MRI. Flexible cerclage reduced annular size but preserved annular motion. Cerclage also displaced the posterior annulus toward the papillary muscles. Cerclage introduced reciprocal constraint to the left ventricular outflow tract and mitral annulus that enhanced leaflet coaptation. A sample of human coronary venograms and computed tomography angiograms suggested that most have suitable venous anatomy for cerclage. CONCLUSIONS: Transcatheter mitral cerclage annuloplasty acutely reduces mitral regurgitation in porcine ischemic cardiomyopathy. Entrapped coronary arteries can be protected. MRI provided insight into the mechanism of cerclage action.


Assuntos
Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Animais , Vasos Coronários/anatomia & histologia , Fluoroscopia , Septos Cardíacos/anatomia & histologia , Imageamento por Ressonância Magnética , Valva Mitral/anatomia & histologia , Insuficiência da Valva Mitral/etiologia , Isquemia Miocárdica/complicações , Cirurgia Assistida por Computador , Técnicas de Sutura , Suínos , Procedimentos Cirúrgicos Vasculares/métodos
20.
J Magn Reson Imaging ; 30(2): 461-5, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19629968

RESUMO

PURPOSE: To develop an "active" (receiver-coil) clinical-grade guidewire with enhanced visibility for magnetic resonance imaging (MRI) and favorable mechanical characteristics for interventional MRI procedures that require conspicuous intravascular instruments distinguishable from surrounding tissues. MATERIALS AND METHODS: We designed a 0.035-inch guidewire combining two antenna designs on separate channels. A loop antenna visualizes the tip and a dipole antenna visualizes the whole shaft. We compared mechanical characteristics of this guidewire with x-ray alternatives and tested MRI performance at 1.5T in vitro and in vivo in swine. RESULTS: Images reflected tip position within 0.97 +/- 0.42 mm and afforded whole-shaft visibility under expected conditions without sacrificing device size or handling. We report tip stiffness, torquability, and pushability comparable to commercial interventional guidewires. CONCLUSION: Our clinical-grade 0.035-inch active guidewire is conspicuous under MRI and has mechanical performance comparable to x-ray interventional guidewires. This may enable a range of interventional procedures using real-time MRI.


Assuntos
Doenças Cardiovasculares/terapia , Imagem por Ressonância Magnética Intervencionista/instrumentação , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...