Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop Traumatol Surg Res ; 103(4): 591-595, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28238964

RESUMO

INTRODUCTION: A novel hybrid anterior cruciate ligament (ACL) reconstruction technique known as Tape Locking Screw™ (TLS) is gaining popularity. Utilizing a suspension-type construct in conjunction with an interference screw, this technique has demonstrated successful initial clinical results with the use of quadruple hamstring graft. However, there is currently limited data available on the biomechanical strength of this fixation. This study investigates the pullout strength of the construct in human distal femora as well as in a porcine model. The construct is tested in isolation, without the use of any graft. We hypothesized that the pullout strength of this construct would be similar to or better than current fixation systems available. MATERIALS AND METHODS: The Tape Locking Screw hybrid fixation system was implanted into twenty-two fresh frozen human distal femora (50-89 years old) randomized to 10×20mm titanium or polyether ether ketone (PEEK) screws by a single sports fellowship trained orthopedic surgeon. Given that the graft is secured to polyethylene terephthalate tape within the construct, the construct was implanted without any graft in order to isolate the device for biomechanical testing. After implantation, a tensile force was applied directly to the loop of tape at a loading rate of 5mm/min using an electromechanical testing system. The failure load was calculated from the resultant load-displacement curve. Specimens were then visually examined for mode of failure. Similar biomechanical tests were performed on sixteen porcine femora. RESULTS: In the human model, the mean pullout strength was 523±269N with the PEEK screw and 578±245N with the titanium screw. In the porcine femur model, mean strength was 616±177N with PEEK, 584±245N with titanium. There was no statistically significant difference in failure loads between these four groups. Tape slippage at the screw bone interface was the primary mode of failure in all the groups tested. DISCUSSION: Our results demonstrate that the hybrid technique provides excellent pullout strength in comparison to other soft-tissue ACL fixation methods, with tape slippage being the mode of failure in all specimens tested. This data, in addition to the advantages of the TLS system, support its consideration in the armamentarium of constructs available for soft-tissue ACL reconstruction. LEVEL OF EVIDENCE: Laboratory controlled study level 2.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/instrumentação , Ligamento Cruzado Anterior/cirurgia , Parafusos Ósseos , Fêmur/cirurgia , Traumatismos do Joelho/cirurgia , Transferência Tendinosa/instrumentação , Idoso , Idoso de 80 Anos ou mais , Animais , Reconstrução do Ligamento Cruzado Anterior/métodos , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Animais , Suínos
2.
J Am Coll Surg ; 190(3): 310-4, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10703856

RESUMO

BACKGROUND: Restorative proctocolectomy is used widely for treatment of ulcerative colitis and familial polyposis coli. Limited information is available regarding the morphologic and functional adaptation of the mucosa in a functioning ileoanal pouch. STUDY DESIGN: Ileal pouch specimens from patients who underwent pouch reconstruction (mean 7.5 years postcolectomy, n = 12) were compared with normal ileum (n = 15) and normal colon (n = 5). Amino-oligopeptidase (AOP) and maltase activity were measured as parameters of normal ileal function. Histologic samples were examined for the presence of neutrophils and plasma cells, the villus to crypt height ratio, and the degree of crypt hyperplasia, villus blunting, and goblet cell mass. Data were analyzed by analysis of variance. RESULTS: The AOP activity in the normal ileum was 73 +/- 32 units of enzymatic activity per gram of mucosal protein; the AOP activities of the pouch and colon were 21 +/- 22 and 16 +/- 10, respectively. The maltase activity of the normal ileum measured 254 +/- 116 units of enzymatic activity per gram of mucosal protein, and the maltase activities of the pouch and colon were 57 +/- 71 units and 29 +/- 25 units, respectively. The ileal pouch mucosa demonstrated little acute inflammation and varying degrees of chronic inflammation. Morphologically, the ileal pouch mucosa demonstrated a range of adaptations, including villus blunting and crypt hyperplasia. Several specimens contained immature epithelial cells. CONCLUSIONS: The AOP and maltase activities in mucosa from ileoanal pouches and colon were significantly lower than those in normal ileal mucosa. Ileoanal pouch mucosa from humans undergoes adaptive changes to resemble colonic mucosa both morphologically and functionally.


Assuntos
Íleo/patologia , Mucosa Intestinal/patologia , Proctocolectomia Restauradora , Adulto , Antígenos CD13/metabolismo , Feminino , Humanos , Íleo/enzimologia , Inflamação/patologia , Masculino , Período Pós-Operatório , alfa-Glucosidases/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...