Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Am J Case Rep ; 21: e925554, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32606285

RESUMO

BACKGROUND Coronavirus disease 2019 (COVID-19) is primarily a respiratory illness. However, with rising numbers of cases, multiple reports of cardiovascular manifestations have emerged. We present a case of COVID-19 infection complicated by myopericarditis and tamponade requiring drainage. CASE REPORT An 82-year-old woman with multiple comorbidities presented with five days of productive cough, fever with chills, and intermittent diarrhea. She tested positive for COVID-19. Index EKG revealed new diffuse T-wave inversions and a prolonged QT interval (>500 ms). Troponin was mildly elevated without any anginal symptoms. Hydroxychloroquine and azithromycin were not initiated due to concerns about QT prolongation. The echocardiogram revealed preserved left ventricular (LV) function, a small global pericardial effusion, and apical hypokinesis. Serial echocardiograms revealed an enlarging circumferential pericardial effusion with pacemaker wire reported as 'piercing' the right ventricular (RV) apex alongside early diastolic collapse of the right ventricle, suggesting echocardiographic tamponade. Chest CT revealed extension of the RV pacemaker lead into the pericardial fat. Interestingly, on comparison with a previous chest CT from 2019, similar lead positions were confirmed. Pericardiocentesis was performed with removal of 400 cc exudate. CONCLUSIONS Acute myopericarditis and pericardial effusion can occur in COVID-19 infection, even in the absence of severe pulmonary disease. This case highlights the importance of awareness of rare cardiac manifestations of COVID-19 in the form of acute myopericarditis and cardiac tamponade and their early diagnosis and management.


Assuntos
Betacoronavirus , Tamponamento Cardíaco/etiologia , Diagnóstico Precoce , Miocardite/complicações , Derrame Pericárdico/etiologia , Pericardiocentese/métodos , Pericardite/complicações , Idoso de 80 Anos ou mais , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Ecocardiografia , Feminino , Humanos , Miocardite/diagnóstico , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/cirurgia , Pericardite/diagnóstico , SARS-CoV-2 , Função Ventricular Esquerda/fisiologia
2.
Am J Case Rep ; 21: e921633, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32107365

RESUMO

BACKGROUND Acute bacterial pericarditis is rare, and the incidence numbers have been declining in the modern antibiotic era. Purulent bacterial pericarditis is a fatal disease in which mortality rates can reach 100% if left untreated. CASE REPORT We present a case of primary purulent bacterial pericarditis with polymicrobial growth including Micromonas micro, Prevotella intermedia and Fusobacterium species, all of which are anaerobic flora of the oral cavity. Constant re-accumulation of the purulent pericardial effusion led the patient to have recurrent echocardiographic and clinical cardiac tamponade requiring recurrent pericardiocentesis' and eventually a pericardial window. CONCLUSIONS Although rare, bacterial pericarditis has been noted to lead to clinical and echocardiographic tamponade. Early diagnosis and treatment are necessary for improving clinical outcomes. It is important to have a suspicion for purulent pericarditis, due to its high level of mortality, in patients who present with non-specific symptoms and pleuritic chest pain.


Assuntos
Bactérias Anaeróbias/efeitos dos fármacos , Tamponamento Cardíaco/microbiologia , Tamponamento Cardíaco/terapia , Pericardite/microbiologia , Pericardite/terapia , Adulto , Antibacterianos/uso terapêutico , Fusobacterium/efeitos dos fármacos , Humanos , Masculino , Pericardiocentese , Prevotella intermedia/efeitos dos fármacos , Doenças Raras
3.
J Cardiovasc Electrophysiol ; 30(10): 2027-2033, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31392815

RESUMO

BACKGROUND AND OBJECTIVES: The use of nonfluoroscopic three-dimensional electroanatomic mapping (3DM) systems reduces radiation exposure during ablation procedures. In this study, we sought to determine the value of 3DM during routine device implant procedures. METHODS: Seventy nonselected patients underwent implantation of a single chamber, dual chamber, or biventricular device guided by Ensite (Abbott Laboratories) to limit fluoroscopy use and compared with 70 consecutive patients, who underwent matching procedures with standard fluoroscopy use (FL) in the period immediately preceding the use of 3DM. The venous anatomy, right atrium, and ventricle and coronary sinus were mapped with 0.035 inch J-wire, quadripolar catheter, and/or angioplasty wire. The leads were advanced under real-time visualization in Ensite. RESULTS: 3DM reduced both fluoroscopy time and dose. Median fluoroscopy time for FL vs 3DM was 5.5 minutes (interquartile range [IQR]: 3.8-8.1) vs 0.9 minutes (IQR: 0.6-1.9) (P < .001) for single chamber devices, 6.3 minutes (IQR: 5.1-7.9) vs 3.3 minutes (IQR: 1.9-4) (P < .001) for dual-chamber devices, and 28.6 minutes (IQR: 19.6-36.2) to 14.7 minutes (IQR: 10.4-22.3) (P = .009) for biventricular devices, respectively. The median air kerma for FL vs 3DM was 15.4 mGy (IQR: 8.1-30.2) vs 4 mGy (IQR: 1.8-8) (P < .001) for single chamber devices, 16 mGy (IQR: 12-18.5) to 9.4 mGy (IQR: 7.5-11.3) (P = .001) for dual-chamber devices, and 324 mGy (IQR: 143-668.7) to 115 mGy (IQR:77-204) (P = .014) for biventricular devices, respectively. There were no procedural complications. At 3-month follow-up, there was no difference in voltage threshold measurements between the groups. CONCLUSION: The use of 3DM leads to significantly reduced fluoroscopy time and fluoroscopy dose during routine device implantation.


Assuntos
Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Imageamento Tridimensional , Marca-Passo Artificial , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Terapia de Ressincronização Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Bases de Dados Factuais , Fluoroscopia , Humanos , Masculino , Segurança do Paciente , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Virginia
6.
Circ Arrhythm Electrophysiol ; 12(2): e006878, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30707036

RESUMO

BACKGROUND: The 12-lead ECG is considered the gold standard to differentiate between selective (S), nonselective (NS) His bundle pacing (HBP), and right ventricular septal capture in routine clinical practice. We sought to assess the utility of device EGM recordings as a tool to identify the type of HBP morphology. METHODS: One hundred forty-eight consecutive patients underwent HBP with a 3830 Select Secure lead (Medtronic, Inc) at 3 centers between October 2016 and October 2017. The near field V-EGM morphology (NF EGM), near field V-EGM time to peak (NFTime to peak), and far-field EGM QRS duration (QRSd) were recorded while pacing the His lead with simultaneous 12-lead ECG rhythm strips. RESULTS: Indications for HBP were sinus node dysfunction, atrioventricular conduction disease, and cardiac resynchronization therapy in 68 (46%), 56 (38%), and 24 (16%) patients, respectively. Baseline QRSd was 108±38 ms with QRSd >120 ms in 57 (39%) patients (27 right bundle branch block, 18 left bundle branch block, and 12 intraventricular conduction delay). S-HBP was noted in 54 (36%) patients. A positive NFEGM and NFTime to peak >40 ms were highly sensitive (94% and 93%, respectively) and specific (90% and 94%) for S-HBP irrespective of baseline QRSd. All 3 parameters (+NFEGM, NFTime to peak >40 ms, and far-field EGM QRSd <120 ms) had high negative predictive value (97%, 95%, and 92%). A novel device-based algorithm for S-HBP was proposed. EGM transitions correlated with ECG transitions during threshold testing and can help accurately differentiate between S-HBP, NS-HBP, and right ventricular septal pacing with a cumulative positive predictive value of 91% (positive predictive value =100% in patients with baseline QRSd <120 ms). CONCLUSIONS: We propose a novel and simple criteria for accurate differentiation between S-HBP, NS-HBP, and right ventricular septal capture morphologies by careful analysis of device EGMs alone. This study paves the way for future studies to assess autocapture algorithms for devices with HBP.


Assuntos
Potenciais de Ação , Arritmias Cardíacas/terapia , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Direita
7.
Europace ; 21(3): 475-483, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30304357

RESUMO

AIMS: Outcome data on ventricular tachycardia (VT) ablation has been limited to few experienced centres. We sought to identify complication rates, predictors, and create a risk score model for predicting complications in patients from real-world data. METHODS AND RESULTS: A total of 25 451 patients undergoing VT ablation from year 2006 to 2013 were identified from the National Inpatient Sample (NIS) database. The whole cohort was randomly divided into derivation cohort to derive the model and validation cohort to validate the model. Multivariate predictors of any complication were identified using regression model. Each predictor was assigned a risk score and each patient was assigned to one of the four groups (risk score in parenthesis) based on total combined risk score: Group 0 (0), Group 1 (1-5), Group 2 (6-10), and Group 3 (>11). The rate of 'any complication' and 'in-hospital mortality' in whole cohort was 14.7% and 2.8%, respectively. The predictors of any complication include chronic kidney disease, coagulopathy, chronic liver disease, stroke (cerebrovascular accident), emergency procedure, age ≥ 65 years, coronary artery disease, peripheral vascular disease, and female gender. There was a significant increase in complication rate in a linear fashion as the risk score increased. The incidence of any complications increased from 2.7% in Group 0 to 31% in Group 3. The risk score model performed well in predicting complications associated with VT ablation. CONCLUSION: Patients with higher risk scores have significant increase in any complication and in-hospital mortality from VT ablation. The simple risk score model can help to risk stratify patients prior to VT ablation.


Assuntos
Ablação por Cateter/efeitos adversos , Técnicas de Apoio para a Decisão , Pacientes Internados , Complicações Pós-Operatórias/epidemiologia , Taquicardia Ventricular/cirurgia , Adulto , Fatores Etários , Idoso , Ablação por Cateter/mortalidade , Bases de Dados Factuais , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
10.
J Cardiovasc Pharmacol Ther ; 23(2): 142-148, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28936878

RESUMO

AIM: Recently, digoxin use has been found to associate with higher mortality. Yet, potential mechanisms by which digoxin use increases mortality remain unclear. Increased arrhythmogenicity from digoxin use is one possibility. Thus, we aimed to evaluate the relation between digoxin and shock events in patients with implantable cardioverter defibrillators (ICDs). METHODS: We performed a retrospective chart review of all patients with ICDs and at least 1 device interrogation at our institution between January 1, 2012, and January 1, 2015. We aimed to cover 1 year of interrogation period. Patients with heart failure, atrial fibrillation, or both were included in the analysis. Patients were divided into 2 groups based on digoxin use, defined as use of digoxin for any period of time during ICD interrogation period. Incidence of ICD shock events and electrical storms and hospitalizations were compared between the 2 groups. RESULTS: The study included 202 patients. Of those, 55 patients were on digoxin and 147 were not on digoxin. Patients on digoxin were more likely to receive ICD shocks (odds ratio [OR] = 2.5, 95% confidence interval [95% CI] = 1.01-6.18, P = .04) and have increased risk of electrical storms ( P = .02). Moreover, total hospitalizations were higher in digoxin users ( P = .02). Multivariate logistic regression analysis also showed that digoxin use was an independent predictor of shock events (OR = 4.07, 95% CI = 1.43-11.58, P = .009). CONCLUSION: Digoxin is associated with increased shock events and electrical storms in patients with ICDs; however, large randomized controlled studies are needed to confirm our findings.


Assuntos
Cardiotônicos/efeitos adversos , Desfibriladores Implantáveis , Digoxina/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Traumatismos por Eletricidade/etiologia , Insuficiência Cardíaca/terapia , Falha de Prótese , Idoso , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/fisiopatologia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Atr Fibrillation ; 10(3): 1645, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29250241

RESUMO

Atrial fibrillation (AF) ablation has emerged as the preferred rhythm control strategy for symptomatic paroxysmal AF refractory or intolerant to at least one class I or III antiarrhythmic medication. Since the initial observation by Haissaguerre and colleagues, of pulmonary vein triggers initiating atrial fibrillation (AF), pulmonary vein isolation (PVI) has become the cornerstone for paroxysmal AF ablation therapy.

15.
J. res. dent ; 5(3): 57-62, may-jun.2017.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1359059

RESUMO

Aim: The present study is conducted to explore the knowledge, attitude towards impact of periodontal diseases on cardiac health among general practitioners. Material and Methods: The present study is a Cross-sectional questionnaire descriptive study. The present study was conducted in a city in Chhattisgarh state among the general dental and medical practitioners running their private clinic. Dental and medical practitioners present on day of survey in the clinic and given their written informed consent were interviewed by the single investigator. Results: To the questions regarding impact of periodontal diseases on cardiac health, 23 (56%) of dental practitioners agree with this fact while for 21 (55%) of medical practitioners says that there is no impact. Majority of study subjects 71 (90%) agree with the statement that patients diagnosed with cardiovascular disease are more likely to have periodontal disease. Forty-two (53%) of study participants agree with the fact that controlling periodontal diseases is important for managing cardiovascular disease. Conclusions: It has been concluded that both dental and medical practitioners had moderate knowledge and fair attitude towards the impact towards impact of periodontal diseases on cardiac health.

16.
Heart Rhythm ; 14(9): 1281-1288, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28438723

RESUMO

BACKGROUND: Minimally invasive surgical atrial fibrillation (AF) ablation (MISAA) delivers radiofrequency energy via a thoracoscopic approach to perform pulmonary vein isolation and left atrial ganglionic plexi ablation. Data on long-term outcomes of MISAA are lacking. OBJECTIVE: We report 5-year follow-up data from a prospective cohort of patients who underwent MISAA at a single center. METHODS: One hundred nine consecutive patients (60 paroxysmal, 49 persistent; mean age 62.7 ± 9.3 years) underwent MISAA with left atrial appendage exclusion by a single surgeon between 2006 and 2012. Patients were followed with transtelephonic monitoring at 1, 6, and 12 months and annually thereafter for up to 5 years. Recurrence was defined as any atrial tachyarrhythmia lasting ≥30 seconds from 90 days after surgery onward. RESULTS: Mean follow-up duration was 1738.5 ± 661.5 days. Single-procedure success rate was 38% (37 of 98 patients). Atrial arrhythmias occurred in 22%, 42%, 55%, 59%, and 62% of patients by 1, 2, 3, 4, and 5 years. Seventy-eight (79.6%) patients remained AF free with or without additional interventions including catheter ablation, antiarrhythmic drugs, or cardioversion. There was no significant difference in AF-free survival between paroxysmal and persistent AF groups (P = .725). Multivariate analyses showed hypertension to be a significant predictor of AF recurrence (odds ratio 6.6, confidence interval 1.41-30.80; P = .016). Five (5.1%) patients had a stroke or transient ischemic attack during follow-up. CONCLUSION: AF-free survival was 38% at 5 years after MISAA. A total of 79.6% of patients remained AF free with or without additional intervention. Patients may have an ongoing risk of stroke even in the absence of AF recurrences.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Toracoscopia/métodos , Fatores de Tempo , Resultado do Tratamento
19.
IEEE Trans Ind Electron ; 64(9): 7304-7312, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33479553

RESUMO

A piezoelectric sensor with a floating element was developed for direct measurement of flow induced shear stress. The piezoelectric sensor was designed to detect the pure shear stress while suppressing the effect of normal stress generated from the vortex lift-up by applying opposite poling vectors to the piezoelectric elements. During the calibration stage, the prototyped sensor showed a high sensitivity to shear stress (91.3 ± 2.1 pC/Pa) due to the high piezoelectric coefficients (d 31=-1330 pC/N) of the constituent 0.67Pb(Mg1∕3Nb2∕3)O3-0.33PbTiO3 (PMN-33%PT) single crystal. By contrast, the sensor showed almost no sensitivity to normal stress (less than 1.2 pC/Pa) because of the electromechanical symmetry of the sensing structure. The usable frequency range of the sensor is up to 800 Hz. In subsonic wind tunnel tests, an analytical model was proposed based on cantilever beam theory with an end-tip-mass for verifying the resonance frequency shift in static stress measurements. For dynamic stress measurements, the signal-to-noise ratio (SNR) and ambient vibration-filtered pure shear stress sensitivity were obtained through signal processing. The developed piezoelectric shear stress sensor was found to have an SNR of 15.8 ± 2.2 dB and a sensitivity of 56.5 ± 4.6 pC/Pa in the turbulent flow.

20.
Case Rep Oncol Med ; 2017: 7304021, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29375920

RESUMO

BACKGROUND: Ibrutinib is a Bruton's tyrosine kinase (BTK) inhibitor approved for second-line treatment for mantle cell lymphoma (MCL), chronic lymphocytic leukemia (CLL), and Waldenström macroglobulinemia. Ibrutinib use has been linked to increased incidence of atrial fibrillation and hypertension in multiple studies. Other forms of cardiac toxicities have also been reported in isolated case reports. Bradycardia and asystole have not been associated with ibrutinib use in the past. CASE REPORT: We present a case of a 76-year-old female with no prior cardiac history, who initiated treatment with ibrutinib for relapsing mantle cell lymphoma and was noted to have symptomatic bradycardia, greater than 20 second long pauses on her cardiac monitor requiring placement of a permanent pacemaker. CONCLUSION: This is the first case associating bradycardia and asystole with tyrosine kinase inhibitor use. Irreversible inhibition of certain cardioprotective tyrosine kinases has been a growing topic of research in oncology therapeutics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...