Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Proc Biol Sci ; 290(2006): 20231332, 2023 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-37700648

RESUMO

Humans exhibit colour vision variations due to genetic polymorphisms, with trichromacy being the most common, while some people are classified as dichromats. Whether genetic differences in colour vision affect the way of viewing complex images remains unknown. Here, we investigated how people with different colour vision focused their gaze on aesthetic paintings by eye-tracking while freely viewing digital rendering of paintings and assessed individual impressions through a decomposition analysis of adjective ratings for the images. Gaze-concentrated areas among trichromats were more highly correlated than those among dichromats. However, compared with the brief dichromatic experience with the simulated images, there was little effect of innate colour vision differences on impressions. These results indicate that chromatic information is instructive as a cue for guiding attention, whereas the impression of each person is generated according to their own sensory experience and normalized through one's own colour space.


Assuntos
Visão de Cores , Humanos , Estética , Polimorfismo Genético
2.
J Neuroendovasc Ther ; 15(10): 681-687, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37502376

RESUMO

Objective: We report the usefulness and pitfalls of coil embolization using the T or half T-stent technique for aneurysms located at internal carotid artery-posterior communicating artery (ICA-P-com) bifurcation in which the neck is wide and the P-com must be kept patent due to it being the fetal-type with a hypoplastic P1 segment. Case Presentations: Two cases were treated using the T-stent technique and two were treated using the half T-stent technique. The average age of the patients was 70.3 years and all were females. One aneurysm ruptured. The average size of aneurysms and neck was 12 mm and 8.5 mm, respectively, in the T-stent group, and 7.4 mm and 6.7 mm, respectively, in the half T-stent group. An S- or pigtail-shaped microcatheter (MC) was used to navigate into the P-com. Stent deployment was successful in all the cases. Retreatment was required in one case treated using the T-stent technique due to major recurrence. Conclusion: T or half T-stent-assisted coil embolization can be an alternative endovascular treatment method for wide-necked ICA-P-com aneurysms in which the P-com must be kept patent due to it being the fetal-type with a hypoplastic P1 segment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...