Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 7430, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38548800

RESUMO

A fiber probe has been developed that enables simultaneous acquisition of mid-infrared (MIR) and Raman spectra in the region of 3100-2600 cm-1. Multimodal measurement is based on a proposed ZrO2 crystal design at the tip of an attenuated total reflection (ATR) probe. Mid-infrared ATR spectra are obtained through a pair of chalcogenide infrared (CIR) fibers mounted at the base of the crystal. The probe enables both excitation and acquisition of a weak Raman signal from a portion of the sample in front of the crystal using an additional pair of silica fibers located in a plane perpendicular to the CIR fibers. The advantages of combining MIR and Raman spectra in a single probe have been discussed.

2.
Anal Chem ; 93(15): 6013-6018, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33821623

RESUMO

A multispectral fiber optic probe has been developed that enables simultaneous analysis of various liquid and solid samples using attenuated total reflection mid-infrared spectroscopy and fluorimetry. The probe design was optimized using ray-tracing simulation of the light propagation. Technical evaluation of the probe has confirmed its output signal quality that was comparable to that of respective probes for single methods. The capability of the probe to deliver complementary chemical information from the same measurement point has been illustrated using model samples of biological tissue. Qualitative analysis of the biological tissue is one of the most important applications of the developed multispectral probe.

3.
Sensors (Basel) ; 20(22)2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33238646

RESUMO

Cancers of the abdominal cavity comprise one of the most prevalent forms of cancers, with the highest contribution from colon and rectal cancers (12% of the human population), followed by stomach cancers (4%). Surgery, as the preferred choice of treatment, includes the selection of adequate resection margins to avoid local recurrences due to minimal residual disease. The presence of functionally vital structures can complicate the choice of resection margins. Spectral analysis of tissue samples in combination with chemometric models constitutes a promising approach for more efficient and precise tumour margin identification. Additionally, this technique provides a real-time tumour identification approach not only for intraoperative application but also during endoscopic diagnosis of tumours in hollow organs. The combination of near-infrared and mid-infrared spectroscopy has advantages compared to individual methods for the clinical implementation of this technique as a diagnostic tool.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Espectrofotometria Infravermelho , Neoplasias Gástricas/diagnóstico por imagem , Humanos
4.
Opt Express ; 28(19): 27940-27950, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32988076

RESUMO

Limited operating bandwidth originated from strong absorption of glass materials in the infrared (IR) spectral region has hindered the potential applications of microstructured optical waveguide (MOW)-based sensors. Here, we demonstrate multimode waveguide regime up to 6.5 µm for the hollow-core (HC) MOWs drawn from borosilicate soft glass. Effective light guidance in central HC (diameter ∼240 µm) was observed from 0.4 to 6.5 µm despite high waveguide losses (0.4 and 1 dB/cm in near- and mid-IR, respectively). Additional optimization of the waveguide structure can potentially extend its operating range and decrease transmission losses, offering an attractive alternative to tellurite and chalcogenide-based fibers. Featuring the transparency in mid-IR, HC MOWs are promising candidates for the creation of MOW-based sensors for chemical and biomedical applications.

5.
Ceska Slov Farm ; 69(5-6): 222-229, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33736448

RESUMO

The article presents the results of the study of the combination of aminosugars - glucosamine hydrochloride (GA h/ch) and N-acetylglucosamine - with quercetin (Q) called GlukvamineTM as a corrector of hepatotoxicity induced by methotrexate (MTX). The study was conducted on a model of MTX-induced liver damage in rats. GlukvamineTM was studied in the dose of 82 mg/kg with daily intragastric administration for 10 days compared to the substance GA h/ch, which was administered intragastrically at a dose of 50 mg/kg, and the substance of Q, which was administered intragastrically in the dose of 20.5 mg/kg. The efficiency of the drugs was assessed by the general condition of the animals, the values of the liver mass coefficient, the biochemical parameters of the blood serum and the histological analysis of the liver tissue. The GlukvamineTM effect on rats with MTX-induced liver damage caused an improvement of their general condition, recovery of the functional state of the liver by biochemical indicators, and the results of the histological analysis indicated a decrease in hepatotoxicity of MTX. At the same time, GlukvamineTM has statistically significantly exceeded the effect of GA h/ch and Q by most parameters. Thus, GlukvamineTM is a promising effective and safe drug for pharmacological correction of the hepatotoxicity of MTX.


Assuntos
Doença Hepática Induzida por Substâncias e Drogas , Metotrexato , Animais , Doença Hepática Induzida por Substâncias e Drogas/tratamento farmacológico , Doença Hepática Induzida por Substâncias e Drogas/etiologia , Doença Hepática Induzida por Substâncias e Drogas/prevenção & controle , Glucosamina/toxicidade , Metotrexato/toxicidade , Estresse Oxidativo , Quercetina , Ratos , Ratos Wistar
6.
Opt Express ; 27(16): 23059-23066, 2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31510588

RESUMO

Laser light sources are routinely applied building blocks in optical sensor technologies. While lasers are emitting at a precisely defined wavelength within narrow emission bands, chem/bio-sensing applications frequently demand multi-wavelength illumination for addressing a series of species. Instead of using broadband radiation sources, it is a viable strategy to efficiently combine the beams emitted from different lasers to maintain the spectral brightness and yet cover extended wavelength regimes. In this study, substrate-integrated hollow waveguides (iHWGs) are reported as a versatile and efficient alternative compared to conventional beam combining concepts, especially for applications in the mid-infrared spectral regime leading to a highly efficient multi-port beam combiner-the iBEAM.

7.
Sensors (Basel) ; 17(11)2017 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-29113084

RESUMO

Matching pairs of tumor and non-tumor kidney tissue samples of four patients were investigated ex vivo using a combination of two methods, attenuated total reflection mid infrared spectroscopy and fluorescence spectroscopy, through respectively prepared and adjusted fiber probes. In order to increase the data information content, the measurements on tissue samples in both methods were performed in the same 31 preselected positions. Multivariate data analysis revealed a synergic effect of combining the two methods for the diagnostics of kidney tumor compared to individual techniques.


Assuntos
Espectrofotometria Infravermelho , Análise Multivariada
8.
Sensors (Basel) ; 17(8)2017 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-28825612

RESUMO

Optical spectroscopy is increasingly used for cancer diagnostics. Tumor detection feasibility in human kidney samples using mid- and near-infrared (NIR) spectroscopy, fluorescence spectroscopy, and Raman spectroscopy has been reported (Artyushenko et al., Spectral fiber sensors for cancer diagnostics in vitro. In Proceedings of the European Conference on Biomedical Optics, Munich, Germany, 21-25 June 2015). In the present work, a simplification of the NIR spectroscopic analysis for cancer diagnostics was studied. The conventional high-resolution NIR spectroscopic method of kidney tumor diagnostics was replaced by a compact optical sensing device constructively represented by a set of four light-emitting diodes (LEDs) at selected wavelengths and one detecting photodiode. Two sensor prototypes were tested using 14 in vitro clinical samples of 7 different patients. Statistical data evaluation using principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) confirmed the general applicability of the LED-based sensing approach to kidney tumor detection. An additional validation of the results was performed by means of sample permutation.


Assuntos
Análise dos Mínimos Quadrados , Análise Discriminante , Humanos , Neoplasias Renais , Análise de Componente Principal , Espectroscopia de Luz Próxima ao Infravermelho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...