Sud Med Ekspert ; 55(4): 43-7, 2012.
Artigo em Russo | MEDLINE | ID: mdl-23008960

RESUMO

The method for the determination of clozapine during chemical studies of cadaveric blood, urine, and liver (kidneys) has been developed based on the use of high performance liquid chromatography. Clozapine losses were estimated at 40-60% with the fractional uncertainty below 10-11% and the detection limit of 0.001 mg%. An algorithm for the estimation of the quality of clozapine isolation and the results of analysis of individual samples is proposed.


Assuntos
Cadáver , Cromatografia Líquida de Alta Pressão/métodos , Clozapina , Toxicologia Forense/métodos , Fígado/química , Algoritmos , Cromatografia Líquida de Alta Pressão/estatística & dados numéricos , Clozapina/sangue , Clozapina/isolamento & purificação , Clozapina/urina , Interpretação Estatística de Dados , Patologia Legal , Humanos , Limite de Detecção