1.
Int Ophthalmol ; 43(11): 4121-4129, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37632576

RESUMO

PURPOSE: To compare intraocular pressure (IOP) measurements between Easyton transpalpebral tonometry and Perkins, iCare iC100 and Corvis ST. Also, to assess the influence of corneal characteristics and anterior scleral thickness (AST) on the IOP measurements. METHODS: Sixty-nine eyes from 69 healthy subjects were included. IOP was measured by Easyton, Perkins, iC100 and Corvis ST (corrected IOP, bIOP; and non-corrected IOP, IOPnct). Other variables studied were AST, axial length (AL), and Corvis parameters: Length 1, velocity 1, length 2, velocity 2, peak distance, radius, deformation amplitude, and central corneal thickness (CCT). Pearson correlation, limits of agreement (LoA), and multiple regression analysis were calculated. RESULTS: No significant differences in IOP between Easyton and Perkins, iC100, and bIOP were observed (all p > 0.05), being significant only between Perkins and IOPnct ( - 1.49 mmHg, p < 0.001). Bland-Altman graphs showed that the mean difference between Perkins and Easyton was 0.07 mmHg (p < 0.001), and LoA - 7.49 to + 7.39 mmHg. Significant correlations were found between the measurements of Perkins and iC100, IOPnct, bIOP (r = 0.710, 0.628, 0.539; p < 0.001 respectively), iC100 and IOPnct, bIOP (r = 0.627, 0.513; p < 0.001, respectively). The multivariate regression analysis revealed that differences between Perkins and Easyton (adjusted R2 = 0.25) were influenced by AL (B = 1.28, p < 0.008), length 1 (B = 3.13, p < 0.018), and the radius (B = 1.26, p < 0.010). Differences between Perkins and bIOP (adjusted R2 = 0.21) were affected by the CCT (B = 0.029, p < 0.003). CONCLUSIONS: There are no significant differences in the IOP measurements between Perkins and Easyton, iC100 or bIOP. Length 1, radius, and CCT have limited influence on these differences, while AST did not show any effect.


Assuntos
Pressão Intraocular , Tonometria Ocular , Humanos , Córnea , Análise de Regressão , Manometria
2.
Pharmaceutics ; 13(6)2021 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-34204254

RESUMO

Currently available anti-scarring treatments for glaucoma filtration surgery (GFS) have potentially blinding complications, so there is a need for alternative and safer agents. The effects of the intrableb administration of a new combination of the anti-VEGF bevacizumab, sodium hyaluronate and a collagen matrix implant were investigated in a rabbit model of GFS, with the purpose of modulating inflammation, angiogenesis, fibroblast migration and fibrogenesis in the wound healing process. A comparative-effectiveness study was performed with twenty-four rabbits, randomly assigned to the following treatments: (a) biodegradable collagen matrix implant (Olo), (b) bevacizumab-loaded collagen matrix implant (Olo-BVZ), (c) bevacizumab-loaded collagen matrix implant combined with sodium hyaluronate (Olo-BVZ-H5) and (d) sham-operated animals (control). Rabbits underwent a conventional trabeculectomy and were studied over 30 days in terms of intraocular pressure and bleb characterization (height, area and vascularity in central, peripheral and non-bleb zones). Histologic differences among groups were further evaluated at day 30 (inflammation, total cellularity and degree of fibrosis in the area of surgery). Local delivery of bevacizumab (Olo-BVZ and Olo-BVZ-H5) increased the survival of the filtering bleb by 21% and 31%, respectively, and generated a significant decrease in inflammation and cell infiltration histologically 30 days after surgery, without exhibiting any local toxic effects. Olo-BVZ-H5 showed less lymphocyte infiltration and inflammation than the rest of the treatments. Intraoperative intrableb implantation of bevacizumab, sodium hyaluronate and a collagen matrix may provide an improved trabeculectomy outcome in this model of intense wound healing. This study showed an effective procedure with few surgical complications and a novel combination of active compounds that offer new possibilities to improve the efficacy of filtration surgery.

3.
Br J Ophthalmol ; 105(7): 957-963, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32703781

RESUMO

BACKGROUND/AIMS: The aim of this study was to assess the optic nerve head (ONH) and macular vessel density with optical coherence tomography angiography (OCT-A) and the ONH haemoglobin (ONH Hb) amount with Laguna ONhE program in open-angle glaucoma (OAG) patients. METHODS: In this prospective observational cross-sectional study, 67 OAG patients and 41 healthy age-sex frequency matched subjects were examined with OCT-A and retinal photos. The circumpapillary (wcpVD), optic nerve head (iVD) and macular (wmVD) capillary vessel density of OCT-A and ONH colorimetric assessment to determine the ONH Hb amount using the Laguna ONhE program were evaluated. RESULTS: Significant differences between normal subjects and glaucoma patients in the wcpVD (22.18±3.42 vs 16.03±2.89%; p<0.001), iVD (18.31±5.56 vs 12.52±4.67%; p<0.001), wmVD (15.60±2.34 vs 13.34±2.32%; p<0.001) and amount of ONH Hb (71.10±1.67 vs 68.86±2.46%; p<0.001) and in the papillary cup (68.14±5.25 vs 64.77±5.08%; p=0.001) were found. The Laguna ONhE glaucoma discriminant function (GDF) index had a negative value in the OAG patients and normal values in healthy subjects (-18.76±13.31 vs 7.98±14.09; p<0.001). The area under the receiver operating characteristic (ROC) curve (AUROC) for discriminating between healthy and glaucomatous eyes was highest for wcpVD (0.93; 95% CI 0.86 to 0.97, p<0.0001), followed by GDF (0.92; 95% CI 0.86 to 0.97, p<0.0001), iVD (0.79; 95% CI 0.70 to 0.86; p<0.0001) and ONH Hb (0.78; 95% CI 0.69 to 0.85, p<0.0001). Pair wise comparisons showed that the AUROC of wcpVD (0.93) was not significantly different than GDF (0.92) (p=0.855). CONCLUSION: Laguna ONhE program and OCT-A have similar diagnostic validity in open-angle glaucoma patients.


Assuntos
Colorimetria , Angiofluoresceinografia , Glaucoma de Ângulo Aberto/fisiopatologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/fisiopatologia , Tomografia de Coerência Óptica , Idoso , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Hemoglobinas/fisiologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Disco Óptico/patologia , Estudos Prospectivos , Células Ganglionares da Retina/patologia , Acuidade Visual/fisiologia
4.
Curr Eye Res ; 45(12): 1534-1542, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32326764

RESUMO

Purpose: To evaluate the optic nerve head (ONH), macular vessel density, and retinal nerve fiber layer (RNFL) thickness differences between the genders. Material and methods: In this prospective case-control cross-sectional study 111 healthy subjects and 130 primary open-angle glaucoma (OAG) patients were examined with optical coherence tomography angiography (OCT-A (RS-3000 Advance (Nidek, Gamagori, Japan))). The vessel density in the peripapillary and macular area as well as the RNFL thickness was evaluated. Results: Men appeared to have less RNFL thickness compared with women in early glaucomatous group, being significant at the whole circumpapillary retinal nerve fiber layer (cpRNFL) thickness and inferior and nasal quadrants: (cpRNFL) (71.01 ± 9.32 vs 77.64 ± 9.95 µm; P = .001), superior quadrant (89.10 ± 16.63 vs 92.97 ± 17.53 µm; P = .284), inferior quadrant (83.03 ± 19.17 vs 95.07 ± 21.70 µm; P = .006), temporal quadrant (57.11 ± 10.36 vs 61.78 ± 11.37 µm; P = .043), nasal quadrant (54.81 ± 11.42 vs 60.73 ± 11.62 µm; P = .016). Circumpapillary (wcpVD) and macular (wmVD) vessel density values were lower in men than women in the early stage OAG group, being wmVD significantly lower: wcpVD (15.53 ± 2.45% vs 16.81 ± 3.17%, P = .032) and wmVD values (12.51 ± 2.21 vs 13.63 ± 2.28%, P = .019), but not in the moderate OAG group (wcpVD 14.46 ± 2.20% vs 16.61 ± 3.10%, P = .056 and wmVD 12.61 ± 2.40% vs 12.74 ± 2.54%, P = .870). There were no significant differences between men and women for RNFL thickness and the vessel density parameters in normal group. Conclusion: Both, the thickness of the nerve fiber layer and peripapillary and macular vessel density are lower in men than in women with glaucoma, more markedly in early stage glaucomatous patients.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Disco Óptico/diagnóstico por imagem , Estudos Prospectivos , Células Ganglionares da Retina/patologia , Vasos Retinianos/diagnóstico por imagem , Fatores Sexuais , Inquéritos e Questionários , Tomografia de Coerência Óptica , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...