Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Biomedicines ; 12(2)2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38398028

RESUMO

Background: This retrospective multicenter study investigates the impact of obesity on short-term surgical outcomes in patients with heart failure and reduced ejection fraction (HFrEF) undergoing coronary artery bypass grafting (CABG). Given the rising global prevalence of obesity and its known cardiovascular implications, understanding its specific effects in high-risk groups like HFrEF patients is crucial. Methods: The study analyzed data from 574 patients undergoing CABG across four German university hospitals from 2017 to 2023. Patients were stratified into 'normal weight' (n = 163) and 'obese' (n = 158) categories based on BMI (WHO classification). Data on demographics, clinical measurements, health status, cardiac history, intraoperative management, postoperative outcomes, and laboratory insights were collected and analyzed using Chi-square, ANOVA, Kruskal-Wallis, and binary logistic regression. Results: Key findings are a significant higher mortality rate (6.96% vs. 3.68%, p = 0.049) and younger age in obese patients (mean age 65.84 vs. 69.15 years, p = 0.003). Gender distribution showed no significant difference. Clinical assessment scores like EuroScore II and STS Score indicated no differences. Paradoxically, the preoperative left ventricular ejection fraction (LVEF) was higher in the obese group (32.04% vs. 30.34%, p = 0.026). The prevalence of hypertension, COPD, hyperlipidemia, and other comorbidities did not significantly differ. Intraoperatively, obese patients required more packed red blood cells (p = 0.026), indicating a greater need for transfusion. Postoperatively, the obese group experienced longer hospital stays (median 14 vs. 13 days, p = 0.041) and higher ventilation times (median 16 vs. 13 h, p = 0.049). The incidence of acute kidney injury (AKI) (17.72% vs. 9.20%, p = 0.048) and delirium (p = 0.016) was significantly higher, while, for diabetes prevalence, there was an indicating a trend towards significance (p = 0.051) in the obesity group, while other complications like sepsis, and the need for ECLS were similar across groups. Conclusions: The study reveals that obesity significantly worsens short-term outcomes in HFrEF patients undergoing CABG, increasing risks like mortality, kidney insufficiency, and postoperative delirium. These findings highlight the urgent need for personalized care, from surgical planning to postoperative strategies, to improve outcomes for this high-risk group, urging further tailored research.

2.
Medicina (Kaunas) ; 58(10)2022 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-36295575

RESUMO

Background and Objectives: The strategy of revascularization may be constrained in patients with insufficient bypass grafts and with increased risk of wound healing disorders. Among those with complex left-sided double-vessel disease in whom a percutaneous coronary intervention (PCI), as well as the surgical procedure of minimally invasive coronary artery bypass grafting via left minithoracotomy (MICS CABG), is not a treatment option, CABG using the left internal mammary artery as a T-graft with itself may be an effective treatment strategy. Materials and Methods: We reviewed the data from patients treated in Cologne and Tuebingen from 2019 to 2022. We included 40 patients who received left internal mammary artery (LIMA) grafting, and additional T-graft with the LIMA itself. The objective was focused on intraoperative and short-term outcomes. Results: A total of 40 patients were treated with the LIMA-LIMA T-graft procedure with a Fowler score calculated at 20.1 ± 3.0. A total of 37.5% of all patients had lacking venous graft material due to prior vein stripping, and 21 patients presented severe vein varicosis. An overall of 2.6 ± 0.5 distal anastomoses (target vessels were left anterior descending, diagonal, intermediate branch, and/or left marginal ramus) were performed, partly sequentially. Mean flow of LIMA-Left anterior descending (LAD) anastomosis was 59.31 ± 11.04 mL/min with a mean PI of 1.21 ± 0.18. Mean flow of subsequent T-Graft accounted for 51.31 ± 3.81 mL/min with a mean PI of 1.39 ± 0.47. Median hospital stay was 6.2 (5.0; 7.5) days. No incidence of postoperative wound healing disorders was observed, and all patients were discharged. There was one 30-day readmission with a diagnosis of pericardial effusion (2.5%). There was no 30-day mortality within the cohort. Conclusions: Patients requiring surgical myocardial revascularization due to complex two-vessel coronary artery disease (CAD) can be easily managed with LIMA alone, despite an elevated Fowler score and a promising outcome. A prospective study needs to be conducted, as well as longer term surveillance, to substantiate and benchmark the long-term results, as well as the patency rates.


Assuntos
Doença da Artéria Coronariana , Artéria Torácica Interna , Intervenção Coronária Percutânea , Humanos , Artéria Torácica Interna/transplante , Doença da Artéria Coronariana/cirurgia , Estudos Retrospectivos , Ponte de Artéria Coronária/métodos , Resultado do Tratamento
4.
BMC Med Educ ; 22(1): 180, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35291993

RESUMO

PURPOSE: During our transthoracic echocardiography (TTE) courses, medical students showed difficulty in spatial orientation. We implemented the use of 3D printed cardiac models of standard TTE views PLAX, PSAX, and A4C and assessed their efficacy in TTE-teaching. METHODS: One hundred fifty-three participants were split into two groups. A pre-test-retest of anatomy, 2D -, and 3D orientation was conducted. The intervention group (n = 77) was taught using 3D models; the control group (n = 76) without. Both were comparable with respect to baseline parameters. Besides test-scores, a Likert scale recorded experiences, difficulties, and evaluation of teaching instruments. RESULTS: From the 153 students evaluated, 123 improved, 20 did worse, and ten achieved the same result after the course. The median overall pre-test score was 29 of 41 points, and the retest score was 35 (p < 0.001). However, the intervention group taught with the 3D models, scored significantly better overall (p = 0.016), and in 2D-thinking (p = 0.002) and visual thinking (p = 0.006) subtests. A backward multivariate linear regression model revealed that the 3D models are a strong individual predictor of an excellent visual thinking score. In addition, our study showed that students with difficulty in visual thinking benefited considerably from the 3D models. CONCLUSION: Students taught using the 3D models significantly improved when compared with conventional teaching. Students regarded the provided models as most helpful in their learning process. We advocate the implementation of 3D-printed heart models featuring the standard views for teaching echocardiography. These findings may be transferable to other evidence based medical and surgical teaching interventions.


Assuntos
Orientação Espacial , Estudantes de Medicina , Ecocardiografia , Humanos , Modelos Anatômicos , Impressão Tridimensional
5.
Medicina (Kaunas) ; 57(11)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34833397

RESUMO

Background: Minimally invasive mitral valve (MV) surgery has emerged as an alternative to conventional sternotomy aiming to decrease surgical trauma. The aim of the study was to describe our experience with minimally invasive MV surgery through partial upper sternotomy (PUS) regarding short- and long-term outcomes. Methods: From January 2004 through March 2014, 419 patients with a median age of 58.9 years (interquartile range 18.7; 31.7% females) underwent isolated primary MV surgery using PUS. Myxomatous degenerative MV disease was the predominant pathology (77%). The patients' mean EuroSCORE II risk profile was 3.9 ± 3.6%. Results: Mitral valve repair was performed in 384 patients (91.6%) and replacement in 35 patients (8.4%). Thirty-day mortality was 3.1%. In total, 29 (6.9%) deaths occurred during the follow-up. The overall estimated survival at 1, 5, and 10 years was 93.1 ± 1.3%, 87.1 ± 1.9%, and 81.1 ± 3.4%. Reoperation was necessary in 14 (3.3%) patients. The overall freedom from MV reoperation at 1, 5, and 10 years was 98.2 ± 0.7%, 96.1 ± 1.2%, and 86.7 ± 6.7% and the overall freedom from recurrent MV regurgitation > grade 2 in repaired valves at 1, 5, and 10 years was 98.8 ± 0.6%, 98.8 ± 0.6%, and 94.6 ± 3.3%. Conclusions: Minimally invasive MV surgery via PUS can be performed with particularly good early and late results. Thus, the PUS approach with the use of standard surgical instruments and cannulation techniques can be a valuable option for the MV surgery either in patients contraindicated or not suitable to minithoracotomy.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Reoperação , Estudos Retrospectivos , Esternotomia , Resultado do Tratamento
6.
3D Print Med ; 7(1): 21, 2021 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-34387785

RESUMO

BACKGROUND: During cardiogenic shock blood circulation is minimal in the human body and does not suffice to survive. The extracorporeal life support system (ECLS) acts as a miniature heart-lung-machine that can be temporarily implanted over major vessels e.g. at the groin of the patient to bridge cardiogenic shock. To perform this procedure in an emergency, a proper training model is desirable. Therefore, a 3-dimensional-printable (3D) material must be found that mimics large vessel needle penetration properties. A suitable test bench for material comparison is desirable. METHODS: A test setup was built, which simulated the clinically relevant wall tension in specimens. The principle was derived from an existing standardized needle penetration test. After design, the setup was fabricated by means of 3D printing and mounted onto an universal testing machine. For testing the setup, a 3D printable polymer with low Shore A hardness and porcine aorta were used. The evaluation was made by comparing the curves of the penetration force to the standardized test considering the expected differences. RESULTS: 3D printing proved to be suitable for manufacturing the test setup, which finally was able to mimic wall tension as if under blood pressure and penetration angle. The force displacement diagrams showed the expected curves and allowed a conclusion to the mechanical properties of the materials. Although the materials forces deviated between the porcine aorta and the Agilus30 polymer, the graphs showed similar but still characteristic curves. CONCLUSIONS: The test bench provided the expected results and was able to show the differences between the two materials. To improve the setup, limitations has been discussed and changes can be implemented without complications.

7.
Biomolecules ; 11(7)2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-34356647

RESUMO

During surgical procedures, cotton abdominal swabs with their high absorptive capacity and malleability are used to retain organs and absorb blood or other body fluids. Such properties of the natural material cotton are advantageous for most operations, but in cardiopulmonary bypass (CPB) surgery, a high blood volume can accumulate in the thoracic cavity that is quickly retransfused via the heart-lung machine (HLM). This common practice is supposed to be safe due to the high anticoagulation. However, in vitro analyses showed that blood cells and plasma proteins were activated despite a high anticoagulation, which can propagate especially an inflammatory response in the patient. Thus, we investigated patients' blood during CPB surgery for inflammatory and coagulation-associated activation after contact to the HLM and either cotton or synthetic abdominal swabs. Contact with cotton significantly increased thrombocyte and neutrophil activation measured as ß-thromboglobulin and PMN-elastase secretion, respectively, compared to synthetic abdominal swabs. Both inflammatory cytokines, interleukin (IL) 1ß and IL6, were also significantly increased in the cotton over the synthetic patient group, while SDF-1α was significantly lower in the synthetic group. Our data show for the first time that cotton materials can activate platelets and leukocytes despite a high anticoagulation and that this activation is lower with synthetic materials. This additional activation due to the material on top of the activation exerted by the tissue contact that blood is exposed to during CPB surgery can propagate further reactions in patients after surgery, which poses a risk for this already vulnerable patient group.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Ativação Plaquetária , Tampões Cirúrgicos , Têxteis , Idoso , Plaquetas/fisiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Fibra de Algodão , Citocinas/sangue , Feminino , Máquina Coração-Pulmão , Humanos , Inflamação/sangue , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Tampões de Gaze Cirúrgicos
8.
Perfusion ; 36(8): 798-802, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33174474

RESUMO

AIM: Patients with cardiogenic shock or ARDS, for example, in COVID-19/SARS-CoV-2, may require extracorporeal membrane oxygenation (ECMO). An ECLS/ECMO model simulating challenging vascular anatomy is desirable for cannula insertion training purposes. We assessed the ability of various 3D-printable materials to mimic the penetration properties of human tissue by using porcine aortae. METHODS: A test bench for needle penetration and piercing in sampled porcine aorta and preselected 3D-printable polymers was assembled. The 3D-printable materials had Shore A hardness of 10, 20, and 50. 17G Vygon 1.0 × 1.4 mm × 70 mm needles were used for penetration tests. RESULTS: For the porcine tissue and Shore A 10, Shore A 20, and Shore A 50 polymers, penetration forces of 0.9036 N, 0.9725 N, 1.0386 N, and 1.254 N were needed, respectively. For piercing through the porcine tissue and Shore A 10, Shore A 20, and Shore A 50 polymers, forces of 0.8399 N, 1.244 N, 1.475 N, and 1.482 N were needed, respectively. ANOVA showed different variances among the groups, and pairwise two-tailed t-tests showed significantly different needle penetration and piercing forces, except for penetration of Shore A 10 and 20 polymers (p = 0.234 and p = 0.0857). Significantly higher forces were required for all other materials. CONCLUSION: Shore A 10 and 20 polymers have similar needle penetration properties compared to the porcine tissue. Significantly more force is needed to pierce through the material fully. The most similar tested material to porcine aorta for needle penetration and piercing in ECMO-implantation is the silicon Shore A 10 polymer. This silicon could be a 3D-printable material in surgical training for ECMO-implantation.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Animais , Aorta , Humanos , Agulhas , SARS-CoV-2 , Choque Cardiogênico , Suínos
9.
Medicina (Kaunas) ; 56(9)2020 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-32842512

RESUMO

Background and Objectives: Since the first use of ventricular assist devices (VADs) as bridge to recovery and bridge to cardiac transplantation in the early 1990s, significant technological advances have transformed VAD implantation into a routine destination therapy. With improved survival, many patients present for cardiac surgery for conditions not directly related to their permanent mechanical circulatory support. The aim of this study was to analyze the indications and outcomes of non-cardiac surgeries (NCSs) of left ventricular assist device (LVAD) patients in tertiary center. Material and Methods: We present a single-center experience after 151 LVAD implantations in 138 consecutive patients between 2012-2019 who had to undergo NCS during a follow-up period of 37 +/- 23.4 months on left ventricular assist device (LVAD). Results: A total of 105 procedures was performed in 63 LVAD recipients, resulting in peri-operative mortality of 3.8%. Twenty-five (39.7%) of patients underwent multiple surgeries. We found no significant difference in cumulative survival associated with the performed surgical interventions (p = 0.469). Conclusion: We demonstrated good overall clinical outcomes in LVAD patients undergoing NCS. With acceptable peri-operative mortality, NCS can be safely performed in LVAD patients on long-term support.


Assuntos
Coração Auxiliar , Assistência Perioperatória , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Anticoagulantes/efeitos adversos , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Procedimentos Cirúrgicos Operatórios/mortalidade
10.
J Card Surg ; 35(7): 1708-1710, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32436599

RESUMO

BACKGROUND: Recurrent ventricular tachycardia (VT) can occur after left ventricular assist device (LVAD) implantation. In this case, medical treatment might be insufficient. We report a case of a left-sided thoracoscopic sympathectomy as a feasible treatment escalation in intractable VT. CASE REPORT: A 72-year-old patient underwent an internal cardioverter defibrillator (ICD) implantation as primary prophylaxis for VTs in the setting of staged heart failure therapy. Afterwards, due to a progressive dilative cardiomyopathy he underwent a minimal-invasive LVAD implantation (HeartWare, Medtronic). After an uneventful minimal-invasive LVAD-implantation the patient was discharged to a rehabilitation program. However, after 7 weeks he developed recurrent VTs which were successfully terminated by ICD shocks deliveries leading to severe discomfort and frequent hospitalizations. Eventually, the patient was admitted with an electrical VT storm. Successful endocardial catheter ablation of all inducible VTs were performed combined with multiple rearrangements of his oral antiarrhythmic medication. However, all these treatments could not suppress further occurrence of VTs. After an interdisciplinary discussion the patient agreed to a left-sided video-assisted thoracoscopic sympathectomy. After a follow up of 150 days the patient was free from VTs apart from one short event. CONCLUSION: We believe video-assisted thoracoscopic sympathectomy might be a surgical treatment option in patients with intractable recurrent VTs after catheter ablation of VT reentrant substrate even after minimal-invasive LVAD implantation.


Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Implantação de Prótese/efeitos adversos , Simpatectomia/métodos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Cirurgia Torácica Vídeoassistida/métodos , Idoso , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Recidiva , Resultado do Tratamento
11.
Knee Surg Sports Traumatol Arthrosc ; 27(3): 971-977, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29761212

RESUMO

PURPOSE: Most biomechanical investigations of tendon repairs were based on output measures from hydraulic loading machines, therefore, accounting for construct failure rather than true gapping within the rupture zone. It was hypothesized that the elastic capacity of a tendon-repair construct influences the force necessary to induce gapping. METHODS: A tendon-repair model was created in 48 porcine lower hind limbs, which were allocated to three fixation techniques: (1) Krackow, (2) transosseous and (3) anchor fixation. Loading was performed based on a standardized phased load-to-failure protocol using a servohydraulic mechanical testing system MTS (Zwick Roell, Ulm, Germany). Rupture-zone dehiscence was measured with an external motion capture device. Factors influencing dehiscence formation was determined using a linear regression model and adjustment performed as necessary. A 3-mm gap was considered clinically relevant. Analysis of variance (ANOVA) was used for comparison between groups. RESULTS: The elastic capacity of a tendon-repair construct influences the force necessary to induce gapping of 3 mm (F3mm) [ß = 0.6, confidence interval (CI) 0.4-1.0, p < 0.001]. Furthermore, the three methods of fixation did not differ significantly in terms of maximum force to failure (n.s) or F3mm (n.s). CONCLUSION: The main finding of this study demonstrated that the higher the elastic capacity of a tendon-repair construct, the higher the force necessary to induce clinically relevant gapping. LEVEL OF EVIDENCE: Controlled biomechanical study.


Assuntos
Elasticidade/fisiologia , Deiscência da Ferida Operatória/fisiopatologia , Traumatismos dos Tendões/cirurgia , Tendões/fisiopatologia , Tendões/cirurgia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Membro Posterior , Humanos , Movimento (Física) , Ruptura , Deiscência da Ferida Operatória/etiologia , Suínos , Traumatismos dos Tendões/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...