Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 123(14): 143003, 2019 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-31702217

RESUMO

We report results of a new technique to measure the electric dipole moment of ^{129}Xe with ^{3}He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is d_{A}(^{129}Xe)=(1.4±6.6_{stat}±2.0_{syst})×10^{-28} e cm. This corresponds to an upper limit of |d_{A}(^{129}Xe)|<1.4×10^{-27} e cm (95% C.L.), a factor of 5 more sensitive than the limit set in 2001.

2.
Magn Reson Med ; 74(3): 884-93, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25213218

RESUMO

PURPOSE: MRI of lung airspaces using gases with MR-active nuclei ((3) He, (129) Xe, and (19) F) is an important area of research in pulmonary imaging. The volume-controlled administration of gas mixtures is important for obtaining quantitative information from MR images. State-of-the-art gas administration using plastic bags (PBs) does not allow for a precise determination of both the volume and timing of a (3) He bolus. METHODS: A novel application unit (AU) was built according to the requirements of the German medical devices law. Integrated spirometers enable the monitoring of the inhaled gas flow. The device is particularly suited for hyperpolarized (HP) gases (e.g., storage and administration with minimal HP losses). The setup was tested in a clinical trial (n = 10 healthy volunteers) according to the German medicinal products law using static and dynamic ventilation HP-(3) He MRI. RESULTS: The required specifications for the AU were successfully realized. Compared to PB-administration, better reproducibility of gas intrapulmonary distribution was observed when using the AU for both static and dynamic ventilation imaging. CONCLUSION: The new AU meets the special requirements for HP gases, which are storage and administration with minimal losses. Our data suggest that gas AU-administration is superior to manual modes for determining the key parameters of dynamic ventilation measurements.


Assuntos
Meios de Contraste/administração & dosagem , Hélio/administração & dosagem , Isótopos/administração & dosagem , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Ventilação Pulmonar/fisiologia , Adulto , Meios de Contraste/química , Meios de Contraste/uso terapêutico , Desenho de Equipamento , Hélio/química , Hélio/uso terapêutico , Humanos , Isótopos/química , Isótopos/uso terapêutico , Imageamento por Ressonância Magnética/instrumentação , Masculino
3.
Magn Reson Med ; 67(6): 1758-63, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22135249

RESUMO

We have developed the means to recycle (3) He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized (3) He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1-2% of (3) He, depending on the amount administered and the number of breaths collected to wash out the (3) He gas from the lungs. (3) He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled (3) He gas features high purity, which is required for repolarization by metastability exchange optical pumping. At present, we achieve a collection efficiency of 80-84% for exhaled gas from healthy volunteers and cryogenic separation efficiency of 95%.


Assuntos
Meios de Contraste/isolamento & purificação , Hélio/isolamento & purificação , Pulmão/fisiologia , Imageamento por Ressonância Magnética/instrumentação , Reciclagem/métodos , Administração por Inalação , Desenho de Equipamento , Análise de Falha de Equipamento , Expiração , Hélio/administração & dosagem , Humanos , Isótopos/administração & dosagem , Isótopos/isolamento & purificação , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/isolamento & purificação
4.
Magn Reson Med ; 65(2): 399-408, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20882641

RESUMO

The aim of this work was to establish a new, fast, and robust method of flip-angle calibration for magnetic resonance imaging of hyperpolarized (3) He. The method called flip-angle measurement with magnetization inversion is based on acquiring images from periodically inverted longitudinal magnetization created using the spatial modulation of magnetization technique. By measuring the width of the area where the magnetization was inverted by the spatial modulation of magnetization preparation in phase images, the flip angle can be generated using a simple equation. To validate and establish the limits of the proposed method, flip-angle measurement with magnetization inversion acquisitions were simulated and applied to proton and hyperpolarized (3) He phantoms. Then, the calibration procedure was applied during hyperpolarized (3) He magnetic resonance imaging in a healthy volunteer. The advantage of the flip-angle measurement with magnetization inversion method compared with the conventional method based on the assessment of radiofrequency-decay is that it is free of errors induced by relaxation due to oxygen, by imperfect excitation slice profile and by any diffusion of (3) He into and out of the slice. Another advantage is that it does not require image processing with external software and therefore can be performed using the implemented tools on the magnetic resonance workstation.


Assuntos
Hélio , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Isótopos , Magnetismo , Masculino , Imagens de Fantasmas
5.
J Magn Reson ; 204(1): 37-49, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20211572

RESUMO

We present novel types of permanently magnetized as well as current powered boxes built from soft-ferromagnetic materials. They provide shielded magnetic fields which are homogeneous within a large fraction of the enclosed volume, thus minimizing size, weight, and costs. For the permanently magnetized solutions, homogenization is achieved either by an optimized distribution of the permanent field sources or by jacketing the field with a soft-ferromagnetic cylindrical shell which is magnetized in parallel to the enclosed field. The latter principle may be applied up to fields of about 0.1T. With fields of about 1mT, such boxes are being used for shipping spin-polarized (3)He worldwide for MRI purposes. For current powered boxes, we present concepts and realizations of uniaxial and tri-axial shielded magnetic fields which are homogeneous on the level of 10(-4) within the entire shielded volume. This is achieved by inserting tightly fitting solenoids into a box from soft-magnetic material. The flexible tri-axial solution suits in particular laboratory applications, e.g. for establishing a spin quantization axis.


Assuntos
Campos Eletromagnéticos , Magnetismo , Modelos Teóricos , Simulação por Computador , Marcadores de Spin
6.
Diabetes Metab ; 32(6): 617-24, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17296516

RESUMO

PURPOSE: The aim of this study was to assess the effect of Ramadan fasting on substrate oxidation in trained athletes during moderate-intensity exercise. METHODS: Nine trained men (age: 19+/-2 yr, Height: 1.78+/-0.74 m) were tested on three occasions: during a control period immediately before Ramadan (C), at the end of the first week (Beg-R), and during the fourth week of Ramadan (End-R). On each occasion, they performed submaximal cycle ergometer exercise, with work-rates that were increased progressively (loadings corresponding to 20, 30, 40, 50, 60% of Wmax). Steady-state substrate oxidation was evaluated by indirect calorimetry. RESULTS: Participants showed significant decreases in body mass and body fat at the end of Ramadan, relative to initial control values (P<0.001). The daily food intake was also reduced during Ramadan (P<0.01). Haemoglobin concentrations and hematocrit were significantly higher at the end-Ramadan, both at rest (P<0.001 and P<0.0001 respectively) and after exercise, (P<0.05 and P<0.01 respectively) compared to control measurements made before Ramadan. At the end of Ramadan, our subjects had increased their fat utilization during exercise. The cross-over was observed at a higher intensity at the End-R (35% vs. 30% of Wmax, P<0.001). For the same power output, the Lipox max was also higher at the End-R, compared to control value (265+/-38 vs. 199.1+/-20 mg/min, P<0.001). CONCLUSION: Ramadan fasting increases the lipid oxidation of trained athletes during submaximal exercise. The increased fat utilisation may be related to decreases in body mass and body fat content.


Assuntos
Ingestão de Energia , Exercício Físico , Jejum/fisiologia , Futebol Americano , Islamismo , Adulto , Glicemia/metabolismo , Teste de Esforço , Hemoglobinas Glicadas/análise , Humanos , Masculino , Tunísia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...