Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Surg Case Rep ; 59: 101-106, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31125787

RESUMO

INTRODUCTION: Retrieval bags are used in laparoscopic cholecystectomies to reduce the risk of bile and gallstone spillage during removal of the gallbladder. Retrieval bag rupture is rare, and its complications have never been previously documented. PRESENTATION OF CASE: A 17-year-old female presented three months post-laparoscopic cholecystectomy with a tender periumbilical mass. Her operative report noted difficulty removing the retrieval bag from the infra-umbilical port site. Imaging of the lump revealed an intra-abdominal fluid collection communicating with the umbilicus. A diagnostic laparoscopy uncovered significant pus in the peritoneal cavity and a gallbladder remnant with multiple gallstones. A combination of sharp and blunt dissections was used to free the gallbladder remnant from its adherent surroundings for removal. A peritoneal washout was performed following extraction of the retained gallstones. The patient's presentation could be traced back to her laparoscopic cholecystectomy where it was confirmed that the retrieval bag ruptured during removal. This would have transected the gallbladder, causing its remnants and associated gallstones to be retained in the peritoneal cavity. DISCUSSION: Retrieval bag rupture can result in retained gallbladder remnants in the peritoneal cavity. Abdominal abscess can manifest months after the initial operation. CONCLUSION: Retrieval bags should be inspected following removal to ensure it is completely intact. Surgeons should consider extending the fascial incision if there is any difficulty during removal. Any damage to the retrieval bag mandates immediate pneumoperitoneum for further exploration of retained products. Governance bodies should incorporate practice guidelines related to retrieval bag rupture as these are currently not present.

2.
JSLS ; 16(1): 89-94, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22906336

RESUMO

INTRODUCTION: Adhesions to mesh/tacks in laparoscopic ventral hernia repair are often cited as reasons not to adopt its evidence-based superiority over conventional open methods. This pilot study assessed the occurrence of adhesions to full-sized Polypropylene and Gore-tex DualMesh Plus meshes and the possibility for adhesion prevention using fibrin sealant. METHODS: Two 10-cm to 15-cm pieces of mesh were placed and fixed laparoscopically in pigs (25kg to 55kg). Group I: 2 animals with Polypropylene mesh on one side and DualMesh on other side. Group II: 2 animals with DualMesh on each side with fibrin sealant applied to the periphery of mesh and staples to one side. Group III: 1 animal with 2 pieces of Polypropylene mesh with fibrin sealant applied to the entire mesh. All animals underwent laparoscopy 3 months later to assess the extent of adhesions, and full-thickness specimens were removed for histological evaluation. RESULTS: More Polypropylene mesh was involved in adhesions than DualMesh. However, with the DualMesh involved in adhesions, more of the surface area was involved in forming adhesions than with Polypropylene mesh. None of the implanted DualMesh had visceral adhesions, while 2 out of 3 Polypropylene meshes had adhesions to both the liver and spleen but none to the bowel. Implanted Polypropylene mesh with fibrin sealant had no adhesions. DualMesh had shrunk more significantly than Polypropylene mesh. Histological evaluation showed absence of acute inflammatory response, significantly more chronic inflammatory response to DualMesh compared to Polypropylene and complete mesothelialization with both meshes. There was extensive collagen deposition between Polypropylene mesh fibers, while fibrosis occurred on both sides of DualMesh with synovial metaplasia over its peritoneal surface akin to encapsulation. CONCLUSIONS: DualMesh caused fewer omental and visceral adhesions than Polypropylene mesh did. Fibrin sealant eliminated adhesions to DualMesh and prevented adhesions to Polypropylene mesh when applied over the entire surface. These results support our current use of DualMesh and fibrin sealant in LVHR.


Assuntos
Adesivo Tecidual de Fibrina/uso terapêutico , Hérnia Ventral/cirurgia , Animais , Laparoscopia , Masculino , Peritônio , Polipropilenos , Telas Cirúrgicas , Suínos , Aderências Teciduais/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...