1.
Bioeng Transl Med ; 9(3): e10519, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38818125

RESUMO

The different immune system cells communicate and coordinate a response using a complex and evolved language of cytokines and chemokines. These cellular interactions carry out multiple functions in distinct cell types with numerous developmental outcomes. Despite the plethora of different cytokines and their cognate receptors, there is a restricted number of signal transducers and activators to control immune responses. Herein, we report on a new class of immunomodulatory signaling molecules based on volatile molecules (VMs, namely, volatile organic compounds [VOCs]), by which they can affect and/or control immune cell behavior and transcriptomic profile without any physical contact with other cells. The study demonstrates the role of VMs by analyzing non-contact cell communication between normal and cancerous lung cells and U937 monocytes, which are key players in the tumor microenvironment. Integrated transcriptome and proteome analyses showed the suggested regulatory role of VMs released from normal and cancer cells on neighboring monocytes in several molecular pathways, including PI3K/AKT, PPAR, and HIF-1. Presented data provide an initial platform for a new class of immunomodulatory molecules that can potentially mirror the genomic and proteomic profile of cells, thereby paving the way toward non-invasive immunomonitoring.

2.
ACS Sens ; 9(1): 126-138, 2024 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-38170944

RESUMO

Cardiac monitoring after heart surgeries is crucial for health maintenance and detecting postoperative complications early. However, current methods like rigid implants have limitations, as they require performing second complex surgeries for removal, increasing infection and inflammation risks, thus prompting research for improved sensing monitoring technologies. Herein, we introduce a nanosensor platform that is biodegradable, biocompatible, and integrated with multifunctions, suitable for use as implants for cardiac monitoring. The device has two electrochemical biosensors for sensing lactic acid and pH as well as a pressure sensor and a chemiresistor array for detecting volatile organic compounds. Its biocompatibility with myocytes has been tested in vitro, and its biodegradability and sensing function have been proven with ex vivo experiments using a three-dimensional (3D)-printed heart model and 3D-printed cardiac tissue patches. Moreover, an artificial intelligence-based predictive model was designed to fuse sensor data for more precise health assessment, making it a suitable candidate for clinical use. This sensing platform promises impactful applications in the realm of cardiac patient care, laying the foundation for advanced life-saving developments.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Inteligência Artificial , Próteses e Implantes , Monitorização Fisiológica
3.
Sens Actuators B Chem ; 398: 134788, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38164440

RESUMO

Online monitoring of prognostic biomarkers is critically important when diagnosing disorders and assessing individuals' health, especially for chronic and infectious diseases. Despite this, current diagnosis techniques are time-consuming, labor-intensive, and performed offline. In this context, developing wearable devices for continuous measurements of multiple biomarkers from body fluids has considerable advantages including availability, rapidity, convenience, and minimal invasiveness over the conventional painful and time-consuming tools. However, there is still a significant challenge in powering these devices over an extended period, especially for applications that require continuous and long-term health monitoring. Herein, a new freestanding, wearable, multifunctional microneedle-based extended gate field effect transistor biosensor is fabricated for online detection of multiple biomarkers from the interstitial fluid including sodium, calcium, potassium, and pH along with excellent electrical response, reversibility, and precision. In addition, a hybrid powering system of triboelectric nanogenerator and solar cell was developed for creating a freestanding, closed-loop platform for continuous charging of the device's battery and integrated with an Internet of Things technology to broadcast the measurements online, suggesting a stand-alone, stable multifunctional tool which paves the way for advanced practical personalized health monitoring and diagnosis.

4.
ACS Sens ; 8(8): 3215-3224, 2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37494456

RESUMO

Stress is becoming increasingly commonplace in modern times, making it important to have accurate and effective detection methods. Currently, detection methods such as self-evaluation and clinical questionnaires are subjective and unsuitable for long-term monitoring. There have been significant studies into biomarkers such as HRV, cortisol, electrocardiography, and blood biomarkers, but the use of multiple electrodes for electrocardiography or blood tests is impractical for real-time stress monitoring. To this end, there is a need for non-invasive sensors to monitor stress in real time. This study looks at the possibility of using breath and skin VOC fingerprinting as stress biomarkers. The Trier social stress test (TSST) was used to induce acute stress and HRV, cortisol, and anxiety levels were measured before, during, and after the test. GC-MS and sensor array were used to collect and measure VOCs. A prediction model found eight different stress-related VOCs with an accuracy of up to 78%, and a molecularly capped gold nanoparticle-based sensor revealed a significant difference in breath VOC fingerprints between the two groups. These stress-related VOCs either changed or returned to baseline after the stress induction, suggesting different metabolic pathways at different times. A correlation analysis revealed an association between VOCs and cortisol levels and a weak correlation with either HRV or anxiety levels, suggesting that VOCs may include complementary information in stress detection. This study shows the potential of VOCs as stress biomarkers, paving the way into developing a real-time, objective, non-invasive stress detection tool for well-being and early detection of stress-related diseases.


Assuntos
Nanopartículas Metálicas , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Hidrocortisona , Ouro , Testes Respiratórios/métodos , Biomarcadores/análise , Estresse Psicológico/diagnóstico
5.
ACS Sens ; 8(3): 1339-1347, 2023 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-36848629

RESUMO

Stress is a leading cause of several disease types, yet it is underdiagnosed as current diagnostic methods are mainly based on self-reporting and interviews that are highly subjective, inaccurate, and unsuitable for monitoring. Although some physiological measurements exist (e.g., heart rate variability and cortisol), there are no reliable biological tests that quantify the amount of stress and monitor it in real time. In this article, we report a novel way to measure stress quickly, noninvasively, and accurately. The overall detection approach is based on measuring volatile organic compounds (VOCs) emitted from the skin in response to stress. Sprague Dawley male rats (n = 16) were exposed to underwater trauma. Sixteen naive rats served as a control group (n = 16). VOCs were measured before, during, and after induction of the traumatic event, by gas chromatography linked with mass spectrometry determination and quantification, and an artificially intelligent nanoarray for easy, inexpensive, and portable sensing of the VOCs. An elevated plus maze during and after the induction of stress was used to evaluate the stress response of the rats, and machine learning was used for the development and validation of a computational stress model at each time point. A logistic model classifier with stepwise selection yielded a 66-88% accuracy in detecting stress with a single VOC (2-hydroxy-2-methyl-propanoic acid), and an SVM (support vector machine) model showed a 66-72% accuracy in detecting stress with the artificially intelligent nanoarray. The current study highlights the potential of VOCs as a noninvasive, automatic, and real-time stress predictor for mental health.


Assuntos
Pele , Compostos Orgânicos Voláteis , Masculino , Animais , Ratos , Ratos Sprague-Dawley , Pele/química , Espectrometria de Massas , Compostos Orgânicos Voláteis/análise , Testes Respiratórios
6.
Adv Sci (Weinh) ; 9(34): e2203693, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36266981

RESUMO

The design and characterization of spatiotemporal nano-/micro-structural arrangement that enable real-time and wide-spectrum molecular analysis is reported and demonestrated in new horizons of biomedical applications, such as wearable-spectrometry, ultra-fast and onsite biopsy-decision-making for intraoperative surgical oncology, chiral-drug identification, etc. The spatiotemporal sesning arrangement is achieved by scalable, binder-free, functionalized hybrid spin-sensitive (<↑| or <↓|) graphene-ink printed sensing layers on free-standing films made of porous, fibrous, and naturally helical cellulose networks in hierarchically stacked geometrical configuration (HSGC). The HSGC operates according to a time-space-resolved architecture that modulate the mass-transfer rate for separation, eluation and detection of each individual compound within a mixture of the like, hereby providing a mass spectrogram. The HSGC could be used for a wide range of applictions, including fast and real-time spectrogram generator of volatile organic compounds during liquid-biopsy, without the need of any immunochemistry-staining and complex power-hungry cryogenic machines; and wearable spectrometry that provide spectral signature of molecular profiles emiited from skin in the course of various dietry conditions.


Assuntos
Imunoquímica , Análise Espectral
7.
ACS Omega ; 7(26): 22484-22491, 2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35811934

RESUMO

On the surface of chemiresistive films, the scarce heterogeneity of a molecularly capped gold nanoparticle (MCGNP) colloidal dispersion and uneven evaporation of the MCGNP-contained drying drop applied to this surface are among the main factors that affect reproducibility, and repeatable fabrication of thin films of MCGNPs. This article shows that an increase in reproducibility and repeatability is possible using a dispersant and a surfactant during the deposition and annealing processes of the MCGNP. The results show higher sensitivity and accuracy of the sensors for the detection of volatile organic compounds in air and an increased limit of detection. These simple and practical additions might serve as a launching pad for fabrication of other types of thin-film-based sensors.

8.
Adv Mater ; 34(3): e2106842, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34741350

RESUMO

Wound healing represents a major clinical and public healthcare problem that is frequently challenged by infection risks, detrimental consequences on the surrounding tissues, and difficulties to monitor the healing process. Here we report on a novel self-healing, antibacterial, and multifunctional wound dressing for sutureless wound closure and real-time monitoring of the healing parameters. The self-healing elastomer contains cetyltrimethylammonium bromide (CTAB) and has high mechanical toughness (35 MJ m-3 ), biocompatibility, and outstanding antibacterial activity (bactericidal rate is ≈90% in 12 h), enabling the wound dressing to effectively inhibit bacterial growth and accelerate infected wound healing. In vivo tests based on full-thickness skin incision model shows that the multifunctional wound dressing can help in contracting wound edges and facilitate wound closure and healing, as could be evidenced by notably dense and well-organized collagen deposition. The test provides an evidence that the integrated sensor array within the multifunctional wound dressing can monitor temperature, pH, and glucose level of the wound area in real-time, providing reliable and timely information of the condition of the wound. Ultimately, the reported multifunctional dressing would be of high value in managing the burden associated with wound healing via personalised monitoring and treatment approaches, digital and other people-centred solutions for health care.


Assuntos
Pele , Infecção dos Ferimentos , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Bandagens , Humanos , Cicatrização
9.
Adv Mater ; 34(10): e2108607, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34918409

RESUMO

Sodium is a prominent prognostic biomarker for assessing health status, such as dysnatremia. As of now, detection and monitoring of sodium levels in the human body is carried out by means of laborious and bulky laboratory equipmentand/or by offline analysis of various body fluids. Herein, an innovative stretchable, skin-conformal and fast-response microneedle extended-gate FET biosensor is reported for real-time detection of sodium in interstitial fluids for minimally invasive health monitoring along with high sensitivity, low limit of detection, excellent biocompatibility, and on-body mechanical stability. The integration of the reported device with a wireless-data transmitter and the Internet-of-Things cloud for real-time monitoring and long-term analysis is reported and discussed. This platform would eventually help bringing unlimited possibilities for effecient medical care and accurate clinical decision-making.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Líquido Extracelular , Humanos , Agulhas , Sódio , Transistores Eletrônicos
10.
Adv Mater ; 32(17): e2000246, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32173928

RESUMO

Integrating self-healing capabilities into soft electronic devices and sensors is important for increasing their reliability, longevity, and sustainability. Although some advances in self-healing soft electronics have been made, many challenges have been hindering their integration in digital electronics and their use in real-world conditions. Herein, an electronic skin (e-skin) with high sensing performance toward temperature, pressure, and pH levels-both at ambient and/or in underwater conditions is reported. The e-skin is empowered with a novel self-repair capability that consists of an intrinsic mechanism for efficient self-healing of small-scale damages as well as an extrinsic mechanism for damage mapping and on-demand self-healing of big-scale damages in designated locations. The overall design is based on a multilayered structure that integrates a neuron-like nanostructured network for self-monitoring and damage detection and an array of electrical heaters for selective self-repair. This system has significantly enhanced self-healing capabilities; for example, it can decrease the healing time of microscratches from 24 h to 30 s. The electronic platform lays down the foundation for the development of a new subcategory of self-healing devices in which electronic circuit design is used for self-monitoring, healing, and restoring proper device function.

11.
Nat Commun ; 10(1): 1120, 2019 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-30850600

RESUMO

Recent years have witnessed thriving progress of flexible and portable electronics, with very high demand for cost-effective and tailor-made multifunctional devices. Here, we report on an ingenious origami hierarchical sensor array (OHSA) written with a conductive ink. Thanks to origami as a controllable hierarchical framework for loading ink material, we have demonstrated that OHSA possesses unique time-space-resolved, high-discriminative pattern recognition (TSR-HDPR) features, qualifying it as a smart sensing device for simultaneous sensing and distinguishing of complex physical and chemical stimuli, including temperature, relative humidity, light and volatile organic compounds (VOCs). Of special importance, OSHA has shown very high sensitivity in differentiating between structural isomers and chiral enantiomers of VOCs - opening a door for wide variety of unique opportunities in several length scales.

12.
Small ; 15(2): e1803939, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30548393

RESUMO

A flexible and stretchable field-effect transistor (FET) is an essential element in a number of modern electronics. To realize the potential of this device in harsh real-world conditions and to extend its application spectrum, new functionalities are needed to be introduced into the device. Here, solution-processable elements based on carbon nanotubes that empower flexible and stretchable FET with high hole-mobility (µh ≈ 10 cm2 V-1 s-1 ) and relatively low operating voltages (<8 V) and that retain self-healing properties of all FET components are reported. The device has repeatable intrinsic and autonomic self-healing ability, namely without use of any external trigger, enabling the restoration of its electrical and mechanical properties, both after microscale damage or complete cut of the device-for example by a scissor. The device can be repeatedly stretched for >200 cycles of up to 50% strain without a significant loss in its electrical properties. The device is applicable in the form of a ≈3 µm thick freestanding skin tattoo and has multifunctional sensing properties, such as detection of temperature and humidity. With this unprecedented biomimetic transistor, highly sustainable and reliable soft electronic applications can be introduced.

SELEÇÃO DE REFERÊNCIAS