Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39031021

RESUMO

AIMS: Ventricular tachycardia (VT) non-inducibility in response to programmed ventricular stimulation (PVS) is a widely used procedural endpoint for VT ablation despite inconclusive evidence with respect to clinical outcomes in high-risk patients. The aim is to determine the utility of acute post-ablation VT inducibility as a predictor of VT recurrence, mortality, or mortality equivalent in high-risk patients. METHODS AND RESULTS: We conducted a retrospective analysis of high-risk patients (defined as PAINESD > 17) who underwent scar-related VT ablation at our institution between July 2010 and July 2022. Patients' response to PVS (post-procedure) was categorized into three groups: Group A, no clinical VT or VT with cycle length > 240 ms inducible; Group B, only non-clinical VT with cycle length > 240 ms induced; and Group C, all other outcomes (including cases where no PVS was performed). The combined primary endpoint included death, durable left ventricular assist device placement, and cardiac transplant (Cox analysis). Ventricular tachycardia recurrence was considered a secondary endpoint (competing risk analysis). Of the 1677 VT ablation cases, 123 cases met the inclusion criteria for analysis. During a 19-month median follow-up time (interquartile range 4-43 months), 82 (66.7%) patients experienced the composite primary endpoint. There was no difference between Groups A and C with respect to the primary [hazard ratio (HR) = 1.21 (0.94-1.57), P = 0.145] or secondary [HR = 1.18 (0.91-1.54), P = 0.210] outcomes. These findings persisted after multivariate adjustments. The size of Group B (n = 13) did not permit meaningful statistical analysis. CONCLUSION: The results of post-ablation PVS do not significantly correlate with long-term outcomes in high-risk (PAINESD > 17) VT ablation patients.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Cicatriz/fisiopatologia , Cicatriz/etiologia , Idoso , Medição de Risco , Resultado do Tratamento , Fatores de Risco
2.
Artigo em Inglês | MEDLINE | ID: mdl-38878017

RESUMO

BACKGROUND: Comparative efficacy and safety data on radiofrequency ablation (RFA) versus pulsed field ablation (PFA) for common idiopathic left ventricular arrhythmia (LV-VAs) locations are lacking. OBJECTIVES: This study sough to compare RFA with PFA of common idiopathic LV-VAs locations. METHODS: Ten swine were randomized to PFA or RFA of LV interventricular septum, papillary muscle, LV summit via distal coronary sinus, and LV epicardium via subxiphoid approach. Ablations were delivered using an investigational dual-energy (RFA/PFA) contact force (CF) and local impedance-sensing catheter. After 1-week survival, animals were euthanized for lesion assessment. RESULTS: A total of 55 PFA (4 applications/site of 2.0 KV, target CF ≥10 g) and 36 RFA (CF ≥10 g, 25-50 W targeting ≥50 Ω local impedance drop, 60-second duration) were performed. LV interventricular septum: average PFA depth 7.8 mm vs RFA 7.9 mm (P = 0.78) and no adverse events. Papillary muscle: average PFA depth 8.1 mm vs RFA 4.5 mm (P < 0.01). Left ventricular summit: average PFA depth 5.6 mm vs RFA 2.7 mm (P < 0.01). Steam-pop and/or ventricular fibrillation in 4 of 12 RFA vs 0 of 12 PFA (P < 0.01), no ST-segment changes observed. Epicardium: average PFA depth 6.4 mm vs RFA 3.3 mm (P < 0.01). Transient ST-segment elevations/depressions occurred in 4 of 5 swine in the PFA arm vs 0 of 5 in the RFA arm (P < 0.01). Angiography acutely and at 7 days showed normal coronaries in all cases. CONCLUSIONS: In this swine study, compared with RFA, PFA of common idiopathic LV-VAs locations produced deeper lesions with fewer steam pops. However, PFA was associated with higher rates of transient ST-segment elevations and depressions with direct epicardium ablation.

3.
Circ Arrhythm Electrophysiol ; 17(6): e012723, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38690671

RESUMO

BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P<0.01 for each. Histology confirmed transmural lesions with both modalities. Experiment II: With PF, lesion depth, width, and volume were larger with higher degrees of CF (depth: r=0.82, P<0.001; width: r=0.26, P=0.052; and volume: r=0.55, P<0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.


Assuntos
Cateteres Cardíacos , Ablação por Cateter , Desenho de Equipamento , Animais , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Suínos , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Modelos Animais , Sus scrofa , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia
4.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38523591

RESUMO

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Assuntos
Fibrilação Atrial , Criocirurgia , Medidas de Resultados Relatados pelo Paciente , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Masculino , Feminino , Criocirurgia/métodos , Fibrilação Atrial/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Sistema de Registros , Qualidade de Vida , Idoso , Ablação por Radiofrequência/métodos
6.
JACC Clin Electrophysiol ; 10(2): 222-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37978965

RESUMO

BACKGROUND: The efficacy of pulsed field ablation (PFA) for redo procedures is unknown. OBJECTIVES: In this study, the authors aimed to evaluate the effectiveness of PFA when performing PFA over chronic RFA (redo environment). METHODS: This was a 3-step in vivo study. In step 1 (creation of redo environment), 6 swine underwent radiofrequency ablation (RFA) with a local impedance measuring catheter and a contact force-enabled catheter in 3 different sites: the right atrium (RA) (intercaval line with intentional gaps), the left atrium (LA) (pulmonary vein isolation [PVI] with intentional gaps and superficial posterior wall ablations), and the left ventricle (LV) (short RFA applications [chronic RFA]). In step 2 (re-ablation), following a survival period of ≈5 weeks, animals were retreated as follows: in the RA, a focal PFA catheter over the prior intercaval line; in the LA, PVI using a pentaspline PFA catheter; and in the LV, animals were randomized to focal PFA or RFA. In each arm, 2 types of lesions were performed: acute or acute over chronic. In step 3 (remapping and euthanization), following an additional 3 to 5 days, all animals were remapped and sacrificed. RESULTS: In the RA, re-ablation with PFA resulted in a complete intercaval block in all animals, expanding and homogenizing the disparate chronic RFA lesions from a width of 4 to 7 mm (chronic RFA) to a width of 16 to 28 mm (PFA over chronic RFA). In the LA, re-ablation with PFA resulted in complete PVI and transmural ablation of the PW. In the LV, the mean depth for acute RFA (post 2-5 days survival) was 7.6 ± 1.3 mm vs 3.9 ± 1.6 mm in the acute over chronic RFA lesions (P < 0.01). In contrast, the mean depth for acute PFA was 7.0 ± 1.6 mm, similar to when ablating with PFA over RFA (7.1 ± 1.3 mm; P = 0.94). CONCLUSIONS: PFA is highly efficient for ablation following prior RFA, which may be beneficial in patients presenting for redo procedures. In the ventricle, PFA resulted in lesions that are deeper than RFA when ablating over chronic superficial RFA lesions.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Humanos , Animais , Suínos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Catéteres , Impedância Elétrica
7.
Circ Arrhythm Electrophysiol ; 17(1): e012026, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152949

RESUMO

BACKGROUND: Effects of contact force (CF) on lesion formation during pulsed field ablation (PFA) have not been well validated. The purpose of this study was to determine the relationship between average CF and lesion size during PFA using a swine-beating heart model. METHODS: A 7F catheter with a 3.5-mm ablation electrode and CF sensor (TactiCath SE, Abbott) was connected to a PFA system (CENTAURI, Galvanize Therapeutics). In 5 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and a skin patch at 40 separate sites in right ventricle (28 Amp) and 55 separate sites in left ventricle (35 Amp) with 4 different levels of CF: (1) low (CF range of 4-13 g; median, 9.5 g); (2) moderate (15-30 g; median, 21.5 g); (3) high (34-55 g; median, 40 g); and (4) no electrode contact, 2 mm away from the endocardium. Swine were sacrificed at 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. In 1 additional swine, COX (cytochrome c oxidase) staining was performed to examine mitochondrial activity to delineate reversible and irreversible lesion boundaries. Histological examination was performed with hematoxylin and eosin and Masson trichrome staining. RESULTS: Ablation lesions were well demarcated with triphenyl tetrazolium chloride staining, showing (1) a dark central zone (contraction band necrosis and hemorrhage); (2) a pale zone (no mitochondrial activity and nuclear pyknosis, indicating apoptosis zone); and a hyperstained zone by triphenyl tetrazolium chloride and COX staining (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). At constant PFA current intensity, lesion depth increased significantly with increasing CF. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions show irreversible and reversible lesion boundaries by triphenyl tetrazolium chloride staining. Electrode-tissue contact is required for effective lesion formation during PFA. At the same PFA dose, lesion depth increases significantly with increasing CF.


Assuntos
Ablação por Cateter , Ventrículos do Coração , Suínos , Animais , Ventrículos do Coração/cirurgia , Ventrículos do Coração/patologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cloretos , Coração , Catéteres
9.
Artigo em Inglês | MEDLINE | ID: mdl-37848806

RESUMO

BACKGROUND: Atrial fibrillation (AF) risk increases with age. We aim to assess the efficacy and safety of catheter ablation in the older population. METHODS: All patients undergoing AF ablation (2013-2021) at our institution were enrolled in a prospectively maintained registry. The primary endpoint was AF recurrence. Patients were divided into 3 groups: non-elderly (< 65 years), elderly (65-75 years), and very elderly (> 75 years). Patient surveys at baseline and during follow-up were used to calculate quality of life (QoL) metrics: the AF severity score as well as the AF burden. RESULTS: A total of 7020 patients were included (42% non-elderly, 42% elderly, and 16% very elderly). Periprocedural major complications were low (< 1.5%) and similar in all groups besides pericardial effusion which was more frequent with older age and similar between the elderly and very elderly. At 3 years, AF recurrence for persistent AF (PersAF) was highest in the very elderly group (48%), followed by the elderly group (42%), and was the lowest in the non-elderly group (36%). In paroxysmal AF (PAF), there was no difference in AF recurrence between the elderly and non-elderly, while the very elderly remained associated with a significantly increased risk. Multivariable Cox analysis confirmed these findings (PersAF; elderly: HR = 1.23, P = 0.003; very elderly: HR = 1.44, P < 0.001) (PAF; elderly: HR = 1.04, P = 0.62; very elderly: HR = 1.30, P = 0.01). Catheter ablation resulted in a significant improvement in quality of life, irrespective of age group. CONCLUSION: Catheter ablation in elderly and very elderly patients is safe, efficacious, and associated with QoL benefits. Overall, major complications were minimal and did not differ significantly between age groups, with the exception of pericardial effusions which were higher in the elderly and very elderly compared to non-elderly adults. Very elderly patients had a higher rate of AF recurrence when compared with elderly or non-elderly patients. Nevertheless, ablation resulted in a remarkable improvement in QoL and a reduction of AF burden and AF symptoms with a similar magnitude, irrespective of age.

10.
JACC Clin Electrophysiol ; 9(9): 1890-1899, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37542488

RESUMO

BACKGROUND: Monomorphic ventricular tachycardia (VT) electrical storm (ES) in patients with coronary artery disease is dependent on scarred myocardium. The role of routine ischemic or coronary evaluations before ablation in patients presenting with monomorphic VT storm, without acute coronary syndrome (ACS), remains unknown. OBJECTIVES: This study sought to assess the impact of ischemic or coronary evaluations on procedural outcomes and post-ablation mortality in monomorphic VT storm patients. METHODS: All patients undergoing VT ablation at the Cleveland Clinic from 2014 to 2020 after presenting with monomorphic VT storm were enrolled in a prospectively maintained registry. The associations among ischemic or coronary evaluations and short-term procedural efficacy, acute outcomes, and mortality during follow-up were assessed. RESULTS: A total of 97 consecutive patients with monomorphic VT storm in the absence of ACS underwent VT ablations. This cohort was characterized by severe LV systolic dysfunction (mean left ventricular ejection fraction 30.3%, 67% with known ischemic cardiomyopathy) with moderately severe heart failure (median NYHA functional class II); 45% of patients underwent ischemic or coronary evaluations via coronary angiography (10%), noninvasive myocardial perfusion (26%), or both (9%). The yield of these evaluations was low: No acute coronary occlusions were identified. There was no association between ischemic evaluation and acute ablation outcomes or mortality during follow-up. Similarly, in a secondary analysis, the yield of ischemic or coronary evaluations in patients with monomorphic VT storm and known coronary disease (regardless of ablation status) was found to be low. CONCLUSIONS: Ischemic evaluations in patients with monomorphic VT storm without ACS may not improve procedural outcomes or mortality after ablation.


Assuntos
Síndrome Coronariana Aguda , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Volume Sistólico , Função Ventricular Esquerda , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Síndrome Coronariana Aguda/complicações , Ablação por Cateter/efeitos adversos
12.
J Cardiovasc Electrophysiol ; 34(8): 1648-1657, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493505

RESUMO

INTRODUCTION: Obesity is a well-known risk factor for atrial fibrillation (AF). We aim to evaluate the effect of baseline obesity on procedural complications, AF recurrence, and symptoms following catheter ablation (CA). METHODS: All consecutive patients undergoing AF ablation (2013-2021) at our center were enrolled in a prospective registry. The study included all consecutive patients with available data on body mass index (BMI). Primary endpoint was AF recurrence based on electrocardiographic documentation. Patients were categorized into five groups according to their baseline BMI. Patients survey at baseline and at follow-up were used to calculate AF symptom severity score (AFSS) as well as AF burden (mean of AF duration score and AF frequency score; scale 0: no AF to 10: continuous and 9 frequencies/durations in between). Patients were scheduled for follow-up visits with 12-lead electrocardiogram at 3, 6, and 12 months after ablation, and every 6 months thereafter. RESULTS: A total of 5841 patients were included (17% normal weight, 34% overweight, 27% Class I, 13% Class II, and 9% Class III obesity). Major procedural complications were low (1.5%) among all BMI subgroups. At 3 years AF recurrence was the highest in Class III obesity patients (48%) followed by Class II (43%), whereas Class I, normal, and overweight had similar results with lower recurrence (35%). In multivariable analyses, Class III obesity (BMI ≥ 40) was independently associated with increased risk for AF recurrence (hazard ratio, 1.30; confidence interval, 1.06-1.60; p = .01), whereas other groups had similar risk in comparison to normal weight. Baseline AFSS was lowest in normal weight, and highest in Obesity-III, median (interquartile range) 10 (5-16) versus 15 (10-21). In all groups, CA resulted in a significant improvement in their AFSS with a similar magnitude among the groups. At follow-up, AF burden was minimal and did not differ significantly between the groups. CONCLUSION: AF ablation is safe with a low complication rate across all BMI groups. Morbid obesity (BMI ≥ 40) was significantly associated with reduced AF ablation success. However, ablation resulted in improvement in QoL including reduction of the AFSS, and AF burden regardless of BMI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Sobrepeso/diagnóstico , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Obesidade/complicações , Obesidade/diagnóstico , Resultado do Tratamento
13.
JACC Clin Electrophysiol ; 9(9): 2008-2023, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37354168

RESUMO

Catheter ablation of arrhythmias is now standard of care in invasive electrophysiology. Current ablation strategies are based on the use of thermal energy. With continuous efforts to optimize thermal energy delivery, effectiveness has greatly improved; however, safety concerns persist. This review focuses on a novel ablation technology, irreversible electroporation (IRE), also known as pulsed-field ablation which may be a safer alternative for arrhythmia management. Pulsed-field ablation is thought to be a nonthermal ablation that applies short-duration high-voltage electrical fields to ablate myocardial tissue with high selectivity and durability while sparing important neighboring structures such as the esophagus and phrenic nerves. There are multiple ongoing studies investigating the potential superior outcomes of IRE compared to radiofrequency ablation in treating patients with atrial and ventricular arrhythmias. In this review, we describe the current evidence of preclinical and clinical trials that have shown promising results of catheter-based IRE.


Assuntos
Arritmias Cardíacas , Ablação por Cateter , Humanos , Arritmias Cardíacas/cirurgia , Eletroporação/métodos , Terapia com Eletroporação , Catéteres , Ablação por Cateter/métodos
14.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1555-1567, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37204356

RESUMO

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) procedures is a rare but potentially serious event. Thrombogenicity and delayed endothelialization play a role in the development of DRT. Fluorinated polymers are known to have thromboresistant properties that may favorably modulate the healing response to an LAAC device. OBJECTIVES: The goal of this study was to compare the thrombogenicity and endothelial coverage (EC) after LAAC between the conventional uncoated WATCHMAN FLX (WM) and a novel fluoropolymer-coated WATCHMAN FLX (FP-WM). METHODS: Canines were randomized for implantation with WM or FP-WM devices and given no postimplant antithrombotic/antiplatelet agents. The presence of DRT was monitored by using transesophageal echocardiography and verified histologically. The biochemical mechanisms associated with coating were assessed by using flow loop experiments to quantify albumin adsorption, platelet adhesion, and porcine implants to quantify EC and the expression of markers of endothelial maturation (ie, vascular endothelial-cadherin/p120-catenin). RESULTS: Canines implanted with FP-WM exhibited significantly less DRT at 45 days than those implanted with WM (0% vs 50%; P < 0.05). In vitro experiments showed significantly greater albumin adsorption (52.8 [IQR: 41.0-58.3] mm2 vs 20.6 [IQR: 17.2-26.6] mm2; P = 0.03) and significantly less platelet adhesion (44.7% [IQR: 27.2%-60.2%] vs 60.9% [IQR: 39.9%-70.1%]; P < 0.01) on FP-WM. Porcine implants showed significantly greater EC by scanning electron microscopy (87.7% [IQR: 83.4%-92.3%] vs 68.2% [IQR: 47.6%-72.8%]; P = 0.03), and higher vascular endothelial-cadherin/p120-catenin expression after 3 months on FP-WM compared with WM. CONCLUSIONS: The FP-WM device showed significantly less thrombus and reduced inflammation in a challenging canine model. Mechanistic studies indicated that the fluoropolymer-coated device binds more albumin, leading to reduced platelet binding, less inflammation, and greater EC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Animais , Cães , Suínos , Polímeros de Fluorcarboneto , Desenho de Prótese , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Trombose/complicações , Inflamação
15.
Circ Arrhythm Electrophysiol ; 16(6): e011565, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183675

RESUMO

BACKGROUND: Ablation is used for both rhythm control and improved quality of life (QoL) in atrial fibrillation (AF). It has been suggested that young adults may experience high recurrence rates after ablation and data remain lacking regarding QoL benefits. We aimed to investigate AF ablation outcomes and QoL benefits in young adults undergoing AF ablation using a large prospectively maintained registry and automated patient-reported outcomes (PRO). METHODS: All patients undergoing AF ablation (2013-2016) at our center were prospectively enrolled. Patients aged 50 years or younger were included. For PROs, QoL measures and symptoms were assessed at baseline, 3 months after ablation, and every 6 months thereafter. The AF severity score served as the main assessment of QoL. RESULTS: A total of 241 young adults (age, 16-50 years) were included (17% female, 40.3% persistent AF). In all, 77.2% of patients remained arrhythmia-free during the first year of follow-up (80% in nonstructural AF and 66% in structural AF). Using PROs, 90% of patients reported improvement in QoL throughout all survey time points up to 5 years postablation (P<0.0001). The baseline median AF severity score was 14 and improved to between 2 and 4 on all follow-up after ablation (P<0.0001). Patients also reported fewer and shorter AF episodes, fewer emergency room visits secondary to AF, and fewer hospitalizations (P<0.0001). CONCLUSIONS: Ablation remains an effective rhythm-control strategy in young adults with AF. Young adults also experience significant improvement in QoL with reduction of the frequency and duration of AF episodes and AF-related healthcare utilization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Feminino , Adulto Jovem , Adolescente , Adulto , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Recidiva
17.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36259719

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Medidas de Resultados Relatados pelo Paciente
18.
Card Electrophysiol Clin ; 14(4): 757-767, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36396191

RESUMO

Current ablation systems rely on thermal energy to produce ablation lesions (heating: RF, laser and ultrasound, and cooling: cryo-thermia). While thermal ablation has been proven to be effective, there are several limitations: 1) relatively long procedural times; 2) high recurrence rate of ventricular arrhythmias; and 3) excessive heating potentially leading to serious complications, including steam pop (perforation), coronary arterial injury and thrombo-embolism. Pulsed field ablation (PFA)/irreversible electroporation (IRE) offers a unique non-thermal ablation strategy which has the potential to overcome these limitations. Recent pre-clinical studies suggest that PFA/IRE might be effective and safe for the treatment of cardiac arrhythmias.


Assuntos
Ablação por Cateter , Criocirurgia , Humanos , Arritmias Cardíacas , Coração , Vasos Coronários
20.
J Cardiovasc Electrophysiol ; 33(9): 1994-2000, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35689504

RESUMO

INTRODUCTION: Pulmonary venous (PV) electrical recovery underlies most arrhythmia recurrences after atrial fibrillation (AF) ablation. Little is known about procedural profiles and outcomes of patients with electrically silent PVs upon redo ablation for AF. METHODS: In a prospectively maintained registry, we enrolled 838 consecutive patients (2013-2016) undergoing redo ablation procedures. Ablation procedures targeted the PVs, the PV antra, and non-PV sites at operators' discretion. Procedural profiles and clinical outcomes were assessed. The primary outcome was freedom from AF after a 3-month blanking period. The secondary outcome was improvement in quality of life. RESULTS: Most patients undergoing redo AF ablation (n = 684, 82%) had PV reconnection while the remaining 154 (18%) had electrically silent PVs. Patients with recurrent AF and electrically silent PVs were older (66 vs. 64 years, p = .02), had more prior ablation procedures (median 2 IQR 1-3 vs 1 IQR 1-2 p = .001), were more likely to have non-paroxysmal AF (62% vs. 49%, p = .004) and atrial flutter (48% vs. 29%, p = .001) and had significantly larger left atrial volumes (89 vs. 81 ml, p = .003). Patients with silent PVs underwent a more extensive non-PV ablation strategies with antral extension of prior ablation sets in addition to ablation of the roof, appendage, inferior to the right PVs, peri-mitral flutter lines, cavotricuspid isthmus lines and ablation in the coronary sinus. Upon one year of follow-up, patients with electrically silent PVs were less likely to remain free from recurrent atrial arrhythmias (64% vs. 76%, p = .008). Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. CONCLUSION: Rhythm control with extensive ablation allowed maintenance of sinus rhythm in about two thirds of patients with silent PVs during redo AF ablation procedures. Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. This remains a challenging group of patients, highlighting the need to better understand non-PV mediated AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...