Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthodont ; 22(6): 451-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23574425

RESUMO

PURPOSE: The purpose of this study was to evaluate the effect of diamond-like carbon thin films doped and undoped with silver nanoparticles coating poly(methyl methacrylate) (PMMA) on Candida albicans biofilm formation. The control of biofilm formation is important to prevent oral diseases in denture users. MATERIALS AND METHODS: Forty-five PMMA disks were obtained, finished, cleaned in an ultrasonic bath, and divided into three groups: Gc, no surface coating (control group); Gdlc, coated with diamond-like carbon film; and Gag, coated with diamond-like carbon film doped with silver nanoparticles. The films were deposited using a reactive magnetron sputtering system (physical vapor deposition process). The specimens were characterized by optical profilometry, atomic force microscopy, and Rutherford backscattering spectroscopy analyses that determined differences in chemical composition and morphological structure. Following sterilization of the specimens by γ-ray irradiation, C. albicans (ATCC 18804) biofilms were formed by immersion in 2 ml of Sabouraud dextrose broth inoculated with a standardized fungal suspension. After 24 hours, the number of colony forming units (cfu) per specimen was counted. Data concerning biofilm formation were analyzed using ANOVA and the Tukey test (p < 0.05). RESULTS: C. albicans biofilm formation was significantly influenced by the films (p < 0.00001), reducing the number of cfu, while not affecting the roughness parameters (p > 0.05). The Tukey test showed no significant difference between Gdlc and Gag. Films deposited were extremely thin (∼50 nm). The silver particles presented a diameter between 60 and 120 nm and regular distribution throughout the film surface (to Gag). CONCLUSION: Diamond-like carbon films, doped or undoped with silver nanoparticles, coating the base of PMMA-based dentures could be an alternative procedure for preventing candidosis in denture users.


Assuntos
Resinas Acrílicas/química , Biofilmes , Candida albicans/fisiologia , Carbono/química , Materiais Revestidos Biocompatíveis/química , Materiais Dentários/química , Diamante/química , Contagem de Colônia Microbiana , Polimento Dentário/métodos , Galvanoplastia/métodos , Humanos , Microscopia de Força Atômica , Nanopartículas/química , Polimerização , Polimetil Metacrilato/química , Prata/química , Espectrofotometria Ultravioleta , Análise Espectral , Propriedades de Superfície , Temperatura , Fatores de Tempo
2.
J Prosthodont ; 19(5): 374-80, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20202103

RESUMO

PURPOSE: To evaluate the effects of the elapsed time (ET) after nonvital bleaching (NVB) and sodium ascorbate application (10%) (SAA) on the shear bond strength of dentin to ceramic. MATERIALS AND METHODS: Bovine incisors were selected, internally bleached (35% carbamide peroxide) for 9 days and submitted to the following treatments (n = 10): G1, G2, G3-luting after 1, 7, and 14 days; G4, G5, and G6-luting after SAA, 1, 7, and 14 days, respectively. G7 and G8 were not bleached: G7-luting 24 hours after access cavity sealing; G8-luting 24 hours after access cavity sealing after SAA. After NVB, the vestibular dentin was exposed and flattened. The SAA was applied to the dentin (G4, G5, G6, G8) for 10 minutes, and it was then washed and dried. The dentin was etched (37% phosphoric acid), and an adhesive system (Single Bond 2) was applied. Feldspathic ceramic discs (VM7; 4-mm diameter, 3-mm thick) were luted with a dual-resin agent (RelyX ARC, 3M ESPE Dental Products, St. Paul, MN). After 24 hours, specimens were submitted to shear test on a universal testing machine. The data (MPa) were submitted to ANOVA and Dunnet's test (5%). RESULTS: The means (+/- SD) obtained were (MPa): G1 (14 +/- 4.5), G2 (14.6 +/- 3.1), G3 (14 +/- 3.7), G4 (15.5 +/- 4.6), G5 (19.87 +/- 4.5), G6 (16.5 +/- 3.7), G7 (22.8 +/- 6.2), and G8 (18.9 +/- 5.4). SAA had a significant effect on bond strength (p= 0.0054). The effect of ET was not significant (p= 0.1519). G5 and G6 presented higher values than the other bleached groups (p < 0.05) and similar to G7 and G8 (p > 0.05). CONCLUSIONS: After NVB, adhesive luting to dentin is recommended after 7 days if sodium ascorbate has been applied prior to dentin hybridization.


Assuntos
Antioxidantes/química , Ácido Ascórbico/química , Cimentação/métodos , Colagem Dentária , Porcelana Dentária/química , Dentina/ultraestrutura , Clareamento Dental/métodos , Condicionamento Ácido do Dente/métodos , Adesividade , Silicatos de Alumínio/química , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Peróxido de Carbamida , Bovinos , Cimentos Dentários/química , Cavidade Pulpar/ultraestrutura , Adesivos Dentinários/química , Ácido Fluorídrico/química , Teste de Materiais , Oxidantes/química , Peróxidos/química , Ácidos Fosfóricos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Compostos de Potássio/química , Distribuição Aleatória , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Fatores de Tempo , Dente não Vital/patologia , Ureia/análogos & derivados , Ureia/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...